Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Fluorescamine

    • Product Name Fluorescamine
    • Alias NSC 19918
    • Einecs 253-260-2
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    177476

    Chemical Name Fluorescamine
    CAS Number 38183-12-9
    Molecular Formula C9H5NO3
    Molecular Weight 175.14 g/mol
    Appearance White to off-white crystalline powder
    Solubility Slightly soluble in water, soluble in organic solvents (e.g., acetone, DMSO)
    Melting Point 187-190°C
    Fluorescence Exhibits strong fluorescence upon reacting with primary amines
    Excitation Wavelength ~390 nm (after reaction with amines)
    Emission Wavelength ~475 nm (after reaction with amines)
    Storage Conditions Store at 2-8°C, protect from light and moisture
    Usage Used for fluorescent labeling of primary amines in proteins and peptides

    As an accredited Fluorescamine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Fluorescamine is supplied in a 1-gram amber glass vial, sealed with a screw cap and labeled with hazard and handling information.
    Shipping Fluorescamine is typically shipped in tightly sealed, moisture-proof containers to prevent hydrolysis, protected from light and air. It is classified as a non-hazardous chemical for transport but should be handled with care due to potential irritancy. Shipping is usually at ambient temperature, following relevant regulatory and safety guidelines.
    Storage Fluorescamine should be stored in a tightly closed container, protected from light and moisture, in a cool, dry, and well-ventilated area. Ideally, store at ≤4°C (refrigerated) to minimize degradation. Avoid contact with strong oxidizing agents and bases. Always handle under inert atmosphere (such as nitrogen or argon) if long-term stability is required.
    Application of Fluorescamine

    Applications of Fluorescamine in Industrial Manufacturing

    As a direct manufacturer of high-purity Fluorescamine, we serve downstream industries requiring sensitive and selective derivatization of primary amines in quality control, diagnostics, and process monitoring environments. Our formulations support large-scale and batch production, addressing compliance, consistency, and application-specific requirements.

    1. Pharmaceutical Quality Control: Protein and Peptide Quantitation

    Several leading pharmaceutical manufacturers use Fluorescamine in automated quality control systems for precise quantitation of peptides and proteins during drug ingredient validation and release testing. This approach supports consistency in biologic substance manufacturing by enabling rapid labeling of primary amine groups for fluorescence-based detection and quantification using high-throughput automated analyzers.

    Industry compliance standards

    • United States Pharmacopeia (USP) monographs for biopharmaceuticals
    • European Pharmacopoeia (Ph. Eur.) protein analysis chapters
    • Good Manufacturing Practice (GMP) regulations (ICH Q7)
    • FDA 21 CFR Part 211 for pharmaceutical quality systems

    Typical usage ratio

    • Between 0.2–1.0 mg/mL in aqueous or phosphate buffer, adjusted to match sample amine concentration; optimized during analytical method development

    Downstream process integration

    • Introduced at the analytical sampling stage before release to QC instrumentation; reaction occurs directly in microtiter plates or flow cells as part of pre-column or post-column derivatization methods

    Final product types

    • Biologics including therapeutic proteins, monoclonal antibodies, recombinant peptides, vaccine components, and release-tested active pharmaceutical ingredient (API) batches

    2. Biotechnology: Amino Acid Analyzer Derivatization Reagent

    Biotechnology companies utilize Fluorescamine as a fluorescent derivatization reagent for amino acid analysis in monitoring fermentation broth, cell culture harvest, and protein hydrolysate characterization. Its rapid reactivity with primary amines enables real-time quantification to optimize fermentation parameters and downstream processing.

    Industry compliance standards

    • ISO 13485 for diagnostics and biomanufacturing equipment
    • U.S. FDA cGMP regulations for biotechnology products
    • EN ISO 17025 for laboratory testing procedures

    Typical usage ratio

    • Ranges from 0.3–0.8 mg/mL in acetonitrile or DMSO solvent, according to system throughput and amino acid content; proportion selected based on instrument linearity requirements

    Downstream process integration

    • Mixed with sample eluates during pre-column derivatization, immediately prior to injection into HPLC or UHPLC amino acid analyzers; enables highly sensitive detection within automated platform workflows

    Final product types

    • Characterized amino acid standards, protein hydrolysates for cell culture, enzyme bulk products, fermentation-derived ingredients, and diagnostic reference samples

    3. Clinical Diagnostics: Clinical Analyzer Reagent Kits

    IVD manufacturers incorporate Fluorescamine into reagent kits for quantifying biologically relevant amines, including biomarkers in human plasma, serum, and urine. These assay kits enable laboratories to detect pathologically elevated primary amine concentrations in a range of metabolic disorders, supporting patient screening and diagnosis.

    Industry compliance standards

    • ISO 13485 certification for IVD device manufacturing
    • CLSI EP5-A3 and EP17-A2 guidelines for analytical performance
    • EU In Vitro Diagnostic Regulation (IVDR 2017/746)
    • FDA 21 CFR Part 820 Quality Systems Regulation

    Typical usage ratio

    • 0.1–0.3 mg/mL in aqueous-compatible buffer within prefilled vials or capsules; adjusted for sample volume and targeted analyte sensitivity

    Downstream process integration

    • Supplied as a ready-to-use reagent mixed with patient samples within automated clinical analyzers; chemiluminescence or fluorescence response measured for clinical readout

    Final product types

    • IVD reagent kits for metabolic assays, diagnostic panel cartridges, and high-sensitivity clinical chemistry test systems

    4. Life Science Research: Laboratory Protein and Peptide Quantitation Kits

    Research tool manufacturers use Fluorescamine in quantitation assay kits for life science research, providing laboratories with a rapid, sensitive means to measure microgram or nanogram levels of proteins or peptides in complex matrices. This supports diverse applications from proteomic sample preparation to assessment of biomolecule purification yields.

    Industry compliance standards

    • ISO 9001 quality management standard for laboratory reagent suppliers
    • Guidelines from major funding institutions for research reproducibility (e.g., NIH, Horizon Europe)
    • OEM test kit QC protocols for batch-to-batch validation

    Typical usage ratio

    • 0.25–0.5 mg/mL in dimethyl sulfoxide (DMSO) or acetone, formulated to ensure stability for up to 12 months shelf-life; adjusted for microplate volume and target analyte range

    Downstream process integration

    • Blended into single-use ampoules or dispensed within microplate assay wells; reaction initiated upon mixing with laboratory sample extract or standard

    Final product types

    • Lab protein quantitation microplate kits, handheld peptide concentration assays, proteomics workflow reagents, and research-use-only (RUO) analysis sets

    5. Environmental Laboratory Testing: Water and Soil Amine Contaminant Detection

    Environmental testing laboratories incorporate Fluorescamine in specialized assays to detect trace-level amine pollutants within surface water, wastewater, and soil extracts. Its high sensitivity supports regulatory compliance for chemical manufacturers, waste management operators, and environmental monitoring agencies.

    Industry compliance standards

    • U.S. Environmental Protection Agency (EPA) Methods, such as EPA 8316 for amines
    • ISO 17025 laboratory accreditation for environmental testing
    • EN 1484 for organic nitrogen analysis in water

    Typical usage ratio

    • 0.15–0.4 mg/mL in methanol or buffered aqueous solution, dosed according to matrix background and environmental detection limits required by regulation

    Downstream process integration

    • Mixed with field or lab sample aliquots following sample extraction and cleanup; detection readout via fluorometry or coupled HPLC analysis

    Final product types

    • Water quality analysis kits, environmental soil screening sets, regulatory compliance reports, and certified reference material panels
    Free Quote

    Competitive Fluorescamine prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Fluorescamine: A Closer Look from the Manufacturer’s Bench

    Practical Insights into Fluorescamine’s Role in Protein and Peptide Analysis

    Every day, we see the requests come in from research centers and QS labs, all with the same straightforward question: Do you have reliable fluorescamine? The answer is yes—and there’s good reason why fluorescamine has stuck around as a preferred reagent in protein and peptide detection. Many people in the materials and biochemistry field recognize its clean performance, but unless you’ve poured out its pale yellow powder and watched it dissolve into solution, the importance of each stage in the preparation may not hit home.

    We’ve been manufacturing fluorescamine for years, and every batch that leaves our facility starts the same way: with raw materials subjected to rigorous scrutiny and a production protocol that doesn’t tolerate short cuts. We know researchers cannot risk inconsistency. In the early 1970s, Robert Udenfriend and his team’s introduction of fluorescamine revolutionized rapid, sensitive detection of primary amines. The method, based on fluorometric measurement, launched a new era because it demanded minimal time and produced quantifiable, interpretable results. For a manufacturer, reproducibility is non-negotiable, because those minutes of hands-on work in the lab can’t be recovered if the reagent falters.

    Our Approach: Molecular Batch, Purity, and Quality Control

    A powdered solid, fluorescamine’s real charm comes alive only in the hands of someone who appreciates sensitive chemistry. Sensitivity depends not just on your instrument but on the reagent’s integrity. We pay attention to moisture content before sealing our packaging; fluorescamine hates water. Even minimal humidity can cause partial hydrolysis, creating the pesky breakdown products that muddy spectrophotometric readings. Only a well-sealed, desiccant-lined amber glass bottle stands a chance at maintaining purity over months and shipment.

    Routine HPLC and FTIR analysis confirm the absence of contaminating peaks, and our final certificate reflects standout purity. Those aren’t afterthoughts—they’re the product not just of standardized protocol but of direct daily oversight. We don’t treat lot-to-lot reproducibility as a formality. Colleagues in academia often speak to the frustration of running a protein concentration assay, only to discover batch variation introduced a new variable. Consistency matters, especially where complex mixtures stand to obscure your true sample composition.

    What Sets Fluorescamine Apart in Analytical Labs

    There’s a myth that every amine-reactive reagent offers the same experience. It just isn’t so. Take o-phthalaldehyde (OPA), ninhydrin, or dansyl chloride. Each has carved a niche, from classic colorimetric tests to fluorescence tagging. Ninhydrin works well for paper chromatography or fingerprint visualization, but often struggles in quantifying lower protein concentrations. Dansyl chloride tags amines reliably, but extensive incubation and separating steps slow down analysis.

    Fluorescamine, on the other hand, reacts instantly—within seconds at room temperature—with primary amines to form a stable, brightly fluorescent product. No waiting for a chromogenic color shift. No complicated high-heat incubation. There’s no response from secondary amines, and it remains insensitive to ammonia, reducing cross-reactions. Laboratories with high sample throughput lean on this property; more samples processed in less time means efficiency isn’t just a buzzword.

    Because fluorescamine doesn’t fluoresce until it forms a product, background interference stays negligible. We’ve stood behind analysts as they scan blank wells before sample addition—no signal, just solid baseline. Compare this to agents with intrinsic fluorescence or lengthy backgrounds, and the advantage becomes palpable. Fewer false positives translate to cleaner data and less troubleshooting in grant-chasing institutions or industrial R&D benches.

    Formulation Details and Storage Specificity

    We ship fluorescamine as an off-white to light yellow crystalline powder, usually with assay values above 99 percent. Any deviation triggers a batch review. Our most widely provided model comes in 250 mg and 1 g vials—enough for thousands of standard assays, with little waste if handled correctly. Opening a new vial, you’ll notice a faint, sharp odor; it’s the chemistry at work, though proper lab ventilation renders it a non-issue.

    Stability persists for over a year in unopened form in a cool, dark location. The moment you open a vial or prepare stock solution, time becomes pressing. Stock solutions in dry acetone or dimethyl sulfoxide last a week or two if shielded from light and moisture. Revisiting old solutions—especially those with cloudiness or unexpected color—invites risk. We recommend single-use aliquots, especially in regulated labs through GMP or ISO systems. Chasing purity for clinical or food analysis, several groups have adopted SOPs that include immediate aliquoting, limiting decomposition and laboratory variables.

    Supporting Reproducibility in Quantitative Applications

    It’s easy to underestimate how dependent outcomes are on simple preparation habits. Every researcher who has ever watched a calibration curve wobble knows the sharp edge of small procedural lapses. As manufacturers, we encourage every group to use glassware rinsed free of all traces of detergent or previous sample, prefer dry solvents, and calibrate pipettes routinely. Analysts investigating trace peptides in CSF or plasma, for example, rely on true linearity between signal and analyte.

    In college teaching labs, students learn to trust their hands—pipetting microliters, mixing within seconds, and detecting nanomole levels of target molecules. Failures almost always trace to two sources: reagent mishandling or substrate contamination. Our work doesn’t end at the production line; we talk regularly with users, piecing together the routine missteps that sabotage quantitation, and we channel this experience back into technical support and batch improvement.

    Fluorescamine versus Other Detection Systems

    Taking the popular ninhydrin test as a comparison, ninhydrin is a colorimetric agent ideal for detecting amino acids in visible light. Yet at nanomolar scales, background noise and variable color intensity limit sensitivity. OPA offers fluorescence, but secondary reactions and time-dependent fading can complicate robust quantification. Fluorescamine, with its quick one-step protocol, bypasses these issues for most primary amine targets.

    One detail emerges from our own stability and stress-testing: OPA preparations degrade visibly with time, and storage in typical glass or plastic vials speeds decomposition. Dansyl chloride can struggle with side-reactions in marine or environmental matrices. By contrast, our testers have pushed fluorescamine across multiple pH and salinity ranges, noting persistence of peak intensity and minimal off-target binding. The most common requests concern compatibility with high-throughput microplate readers, and through direct trial, we’ve worked out dilution protocols that suppress well-to-well crosstalk.

    Trouble-Shooting and Field Reports: Where Theory Meets Practice

    No production batch is complete without running real-world tests far beyond standard benchmarks. Our technical group gets regular feedback from proteomics researchers, pharmaceutical QA, even forensic groups in need of discrete amine labeling. The nuances that emerge surprise even our seasoned chemists. For one protein fingerprinting project, a user found persistent fluorescence suppression. Backtracking revealed that residual buffer contaminants—specifically tris or glycine—competed for reagent, altering the readout. Such hiccups put the manufacturer’s commitment front and center.

    To stave off avoidable pitfalls, our notes go out with every pack: plan for single-use solubilization, watch for amine contamination in plastics, skip strong nucleophilic buffers when feasible, and run a calibration curve each day. Users working with microfluidic chips, for instance, have mentioned silicone-based coatings bind trace fluorescamine, sapping signal. Our feedback loop with end-users has pushed us to optimize lidding and packaging since certain cap liners leached over time.

    The Safety Conversation: Handling and Ergonomics

    Though fluorescamine occupies a well-understood chemical niche, its reactive nature demands respect. Direct skin or ocular contact feels rapidly uncomfortable, and inhalation is ill-advised. In our own facility, gloves, glasses, and powder hoods are routine, not optional. We’ve learned from seasoned operators that spills, though rare, are a painful reminder of the need for vigilance. End-user safety matters, so we advocate unambiguous labeling and handling instructions—as much as to protect product integrity as operator health.

    Safe transport plays in as well. We made the switch to more robust, desiccated glass bottles following a warehouse mishap involving moisture-induced clumping. In shipment across humid climates, we supplement with additional desiccants. In some instances, a single broken seal can compromise an entire batch, so we test samples after transit as a matter of policy.

    Real Uses in Modern Laboratories—From Protein Quantitation to Analytical Toxicology

    Application areas for fluorescamine multiply every year. Academic labs mostly use it in quantitating protein or peptide concentrations, particularly in samples that can’t tolerate harsh conditions or extensive sample cleanup. Biotechnological fields make use of its small sample footprint, processing dozens or hundreds of plasma or urine specimens per run. In environmental analysis, fluorescamine tags trace pesticides or biogenic amines, revealing low-level contamination in food or water with rapid turnaround.

    Clinical and pharmaceutical disciplines leverage its specific reactivity and low cross-reactivity. No analyst wants to redraw a calibration curve after each batch; they count on day-to-day stability. Toxicology panels, especially in drug monitoring programs, spot-check unknown amine-containing agents using this reagent. In some cases, we’ve seen forensics professionals adapt the chemistry for detection of new psychoactive substances—a far cry from its original protein work.

    Time matters in all of these scenarios. Busy labs don’t want to babysit reaction mixtures. The quick reaction makes it possible to take a sample, add fluorescamine, and start reading fluorescence almost immediately. Drug development programs, operating under compressed schedules, squeeze extra efficiency from this simplicity. It means less time troubleshooting and less risk of sample degradation in warm climates or low-resource contexts.

    Feedback from Analytical Chemists: Meeting Evolving Priorities

    Reliable communication with end-users has driven improvements beyond just chemical purity. Some groups requested broader lot-test reports to aid in regulated environments, and we responded by standardizing additional impurity reporting through LC-MS and spectral overlays. Many clinical labs asked for tamper-evident closures and easier batch traceability. By following up on these requests, we reinforce confidence—not just in the bottle, but in the people behind its production.

    We learn from every new feedback cycle. Analytical staff often want documentation denoting compliance with standards like ISO 9001, and regulatory audits routinely examine our manufacturing logs. To satisfy this, we keep clear, digital records spanning each production step, from incoming raw material identity confirmation to outgoing courier hand-off.

    Environmental impact creeps into the conversation, too. As a responsible producer, we examine not just toxicity to operators, but waste byproducts at the user end. While fluorescamine itself presents little volatility, disposal of acetone-based solutions or contaminated pipette tips forms an environmental concern. Partnering with waste management groups, we’ve helped set up programs to collect and process hazardous remnants, doing our part to keep bench chemistry sustainable.

    Emerging Trends in Protein Chemistry and Labeling

    Protein and peptide chemistry isn’t standing still. Demands in next-generation sequencing, single-cell analysis, and point-of-care diagnostics all push for higher sensitivity, faster throughput, and lower cross-reactivity. Fluorescamine’s legacy lies partly in its predictability, partly in its openness to adaptation. One trend sees its use expanded into chip-based bioanalytic arrays. Another is the push for miniaturized, automation-friendly formats to fit into robotic sample handlers.

    We maintain open conversations with device manufacturers to tune solvent compatibility, minimize adsorption, and test reagent blends under diverse field conditions. Our staff gets involved in troubleshooting calls, sometimes within hours of a run, to pinpoint bottlenecks or confirm time windows for best signal. Laboratories testing new immunoassay platforms want assurances that even trace contaminants won’t confound data integrity.

    Future Solutions: Tackling Persistent Laboratory Obstacles

    The goal is never just to supply a powder. We’re in the business of engineering smoother workflows. Recent months brought us challenges with emerging multiwell screening platforms, demanding still finer control over dust and particle introduction. We responded by refining our powder sieving step, ensuring no clumping or static. Experienced staff walk each lot through the process, eyes on the smallest anomalies.

    Speaking with environmental chemists, we see recurring concern about reagent shelf-life in tropical labs without air conditioning. Our answer: offer pre-scored, single-use ampoule vials, which eliminate repeated opening and provide robust shelf stability. Some regulatory agencies now recognize these container-closure systems as preferable for preserving documentation and batch traceability.

    Long-term, our development team is investigating alternate solvent systems for preparing stock solutions. Acetone isn’t perfect—especially for those with stricter environmental discharge limits. Early trials with acetonitrile and DMSO routes look promising on the stability front, though fluorescence yield depends on careful stoichiometry adjustments. These issues remind us chemistry isn’t theoretical, it’s practical—choices in the factory echo out to the end user’s bench.

    Direct Honesty and Enduring Quality: Our Commitment

    Chemistry shouldn’t require leaps of faith. The reassuring thing about fluorescamine, when made by conscientious hands, is its lack of surprises. Researchers, drug developers, food safety inspectors—none want unexpected peaks or ghost signals. As a manufacturer, we owe it to the people relying on this tool not only to meet but exceed reproducibility benchmarks. We remain present for the awkward questions and rare oddities that only daily hands-on practice brings.

    Our shared goal across science is clarity and actionable results. At the core, fluorescamine is as much about trust as it is about detection. We invite ongoing dialogue as the chemistry community’s needs change. Whether troubleshooting a finicky protein prep, scaling up to automated mixing, or addressing environmental concerns in waste disposal, our approach stays anchored: deliver pure product, back it up with honest communication, and embrace change led by real lab experience.

    In the end, every well-read fluorescence plate, smooth protein quantitation, or stuck diagnostic needs a solid foundation. That job falls to us, and we do it with purpose born from experience—not marketing theory. We welcome any question, and strive to keep fluorescamine production as transparent and collaborative as the research it supports.