|
HS Code |
426149 |
| chemical_name | Unifiram |
| cas_number | 272786-64-8 |
| molecular_formula | C13H15NO3S |
| molar_mass | 265.33 g/mol |
| appearance | White crystalline powder |
| synonyms | DM-232 |
| route_of_administration | Oral |
| mechanism_of_action | AMPA receptor positive allosteric modulator (suspected) |
| therapeutic_class | Nootropic |
As an accredited Unifiram factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for Unifiram consists of a sealed amber glass bottle containing 5 grams of fine white powder, labeled with product details. |
| Shipping | Unifiram is shipped in compliance with relevant regulations, typically sealed in secure, airtight containers to prevent contamination and degradation. All packages are clearly labeled with necessary hazard information. The shipping process ensures temperature and light control if required, and all documentation accompanies the shipment for regulatory and safety compliance. |
| Storage | Unifiram should be stored in a cool, dry, and well-ventilated area away from direct sunlight, heat sources, and moisture. Keep the container tightly closed when not in use. Store it at room temperature, ideally between 2-8°C (36-46°F). Ensure proper labeling and protect from incompatible materials, such as strong oxidizers. Follow relevant safety and regulatory guidelines for storage. |
| Purity 99%: Unifiram with purity 99% is used in neuroscience research, where enhanced synaptic plasticity and cognitive enhancement are observed.Melting Point 57°C: Unifiram with a melting point of 57°C is applied in pharmaceutical formulation, where stable compound integration improves bioavailability.Particle Size <10 µm: Unifiram with particle size less than 10 µm is utilized in oral dosage preparation, where increased dissolution rate and absorption efficiency are achieved.Stability Temperature 25°C: Unifiram with stability at 25°C is used in long-term storage for pharmacological studies, where consistent potency and efficacy are maintained.Optical Purity >98%: Unifiram with optical purity greater than 98% is employed in enantioselective analysis, where precise receptor-target interactions are ensured.Solubility 15 mg/mL: Unifiram with solubility of 15 mg/mL is implemented in liquid formulations for preclinical trials, where rapid systemic delivery is facilitated.Moisture Content <0.5%: Unifiram with moisture content less than 0.5% is used in tablet production, where extended shelf-life and controlled release properties are provided.Assay Value 98.5%: Unifiram with an assay value of 98.5% is utilized in cognitive performance experiments, where accurate dosing and reproducible results are achieved. |
Competitive Unifiram prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Years of hands-on work in our R&D labs have taught us the impact that subtle molecular differences can have on an entire synthesis process. Some compounds appear minor on paper, yet transform workflows in meaningful ways. Unifiram delivers on that front for scientists seeking greater reliability and performance in cognitive agent studies. We developed our Unifiram model with technical rigor and transparent production methods. Each batch reflects clear, controlled steps in crystallization, drying, and purification. By tightly managing these operations ourselves, we avoid cross-contamination risks and minimize unwanted byproducts that can complicate results or skew downstream analytical work.
Conversations with formulating chemists and research teams underscore something few technical documents mention: purity isn’t just a number on a COA. The value comes from real-world confidence—are you working with what you think you’re working with, run after run? Our Unifiram comes out above 99% purity—regular HPLC and NMR checks confirm consistency. It holds up during stability protocols in standard storage conditions, without spontaneous byproduct formation. We use microcrystalline forms that disperse evenly, so weighing and blending in lab practice stay hassle-free. Such consistency owes more to careful environmental controls and staff vigilance during processing than to any shortcut solution.
In actual synthesis, details matter: melting range, particle size, and moisture levels can all shift results. Our Unifiram’s melting point runs 53-57 °C—a window steady enough to resist clumping or caking during routine handling. Moisture content stays below 0.5%, a level chosen to sidestep hydrolysis or background formation of related compounds. Our size range supports quick solubilization in standard experimental solvents, especially DMSO and ethanol, letting users sidestep common dissolution headaches that waste valuable time.
We care about the full lifecycle, from raw material sourcing to waste flows. Every drum gets labeled and sealed under filtered air, with lot histories tracing right back to supply chain entry points. Auditable documentation isn’t an afterthought here; direct manufacturer records get stored with each production cycle. If something ever goes wrong, we can retrace every step—nothing falls through the cracks.
The practical reality for bench chemists lies in predictable behavior and minimal troubleshooting. Our customers in academic pharmacology and private biotech outfits tell us Unifiram stays stable between room and refrigeration temperatures, without loss of potency or visible degradation, even during repeated restocking. We design for shelf life, so an open drum doesn’t force a line of technicians to scramble and rush through their test plans.
In dosing and solution prep, homogeneity and fast dispersal define daily convenience. We standardize crystal habit and minimize fines, reducing dust and spill hazards during transfer. Solid form decisions come from listening to the people weighing, mixing, and analyzing—not just ticking regulatory boxes or chasing process economy. Narrow PSD curves let users expect the same solution concentration day after day.
Some other suppliers bulk out products or cut them with flow agents. Our experience shows that even tiny additives change compound interaction, especially in precision dosing or when dissolved at high concentrations for titration or bioassays. With Unifiram, technicians work with pure actives, not blends or composites.
Many researchers approach Unifiram as an alternative to conventional ampakines, piracetam analogs, or modafinil derivatives. It stands apart with its unique chemical backbone, which shows greater potency in synaptic modulation than standard racetams, sometimes at fractions of the dose. We have observed in direct comparative tests that, milligram for milligram, our Unifiram requires less product to achieve the same in-vitro activity endpoints than structurally related compounds. This allows for lower material use per trial, potentially reducing cost and simplifying logistics in routine research settings.
Unifiram's physical profile—powder rather than granular—reduces sticking and clumping inside automated dispensers or semi-automatic pipetting setups. This improves uptime in high-throughput workflows, where sticking or bridging wastes technician effort and skews metered charges.
Standardization is another focus: our Unifiram batches undergo rigorous reference matching, so properties like melting range, solubility, and spectral data stay in sync from lot to lot. Customers say this makes protocol revalidation quicker, as fewer “surprise” deviations crop up between supplies. From a chemist’s seat, peeling open a drum and finding powder that blends without extra force or static, dissolves quickly in common lab solvents, and responds to analysis with expected peaks makes a large difference.
Laboratory groups trust us because we skip corners and provide deep supporting documentation. We follow Good Manufacturing Practices, but the everyday wins come from methodically double-checking every step. Batch QC runs in parallel with process-scale production; no run ships until we’ve verified purity against our own reference samples.
We also hear from clients who’ve moved away from products routed through distributors, where traceability or retention times can fall short, or where batch blending obscures minor—but important—composition differences. Using directly-manufactured Unifiram gives research projects tight control over their variables, supporting reproducibility and easier troubleshooting.
Customer scientists often report cleaner baseline measurements during routine pharmacology or biophysics screening when using our Unifiram. Fewer signal artifacts and baseline drifts make downstream analysis easier for teams. Biotech developers testing new delivery formulations notice improved formulation behavior—fewer phase-separation incidents or precipitation on storage.
Our technical service team fields questions daily, ranging from solvent choice to storage practice to preventive cleanup. Reflecting on these calls, we find that troubleshooting is a breeze when a product is made close to the intended final use, with all support data on hand. We never resort to standardized handwaving or generic replies. Every product shipment comes with lot-specific characterization results. For example, NMR and HPLC spectra are provided alongside UV and moisture analyses, so researchers can verify with their own records and spot-check for themselves. This transparency gives peace of mind and helps build the habit of verification that sound science requires.
For those scaling from benchtop experiments to pilot scale, our Unifiram offers the same properties, whether purchasing a few grams or scaling to multiple kilograms. This predictable behavior remains a key factor for formulation specialists, who rely on accurate composition when developing dose vehicles or releasing pilot batches to internal stakeholders.
Talking shop with formulation scientists, we often compare Unifiram to established compounds like Piracetam, Aniracetam, and Phenylpiracetam. Unifiram's design confers a higher affinity toward specific AMPA receptor sites, as observed in lab models, with reduced off-target responses at similar test concentrations. Having worked with each of these compounds in our cleanrooms, we’ve learned that even minor differences in composition complicate things at scale—water uptake, granulation rates, and powder behavior can diverge in subtle ways.
Our Unifiram demonstrates more robust moisture resistance than many Piracetam analogs, needing less frequent re-testing or re-drying. It also displays lower static charge buildup, a real advantage for users employing automated transfer systems or microgram-scale dosing setups. Less dust means fewer cleanroom interventions and less risk of operator exposure.
In neuroactive chemical development, some analogs include stabilizers or antioxidants in the raw material. Our direct synthesis sidesteps this dependency, yielding Unifiram with long-term stability and no need for additional excipients. This supports those building complex, multi-component studies where extra variables only add analytical noise.
Many clients—especially those moving beyond early proof-of-concept—stress the importance of direct communication with the manufacturer. We welcome dialogue, whether the question is about shelf life, analytical strategy, or risk control. By controlling our own input chain and documenting each synthesis phase, we give scientists a living record for every lot. These records tie back to starting material lots, process controls, equipment logs, and final QA signoff.
We witness firsthand the confusion that arises when a research team encounters unexpected compound behavior and finds only generic datasheets or unfamiliar batch histories. Through our direct workflow model, research groups reduce these risks. If a project hits a roadblock, our support team can access full run data—NMR, HPLC, DSC, water content, and storage history. This access proves invaluable when troubleshooting an anomaly or investigating an unexpected observation in a rat or mouse model.
We never rely on third-party relabelers or market consolidators. What leaves our facility has one chain of custody, direct from maker to user. For clients working under grant funding or regulatory audit, this straightforward documentary trail holds real compliance value and saves future headaches.
Large chemistry groups want evidence that behavior at gram scale matches multi-kilo output. We emphasize process repeatability, with rigorous tracking of tools, batch notes, and operator checks. Unifiram remains process-stable, supporting expansion from academic research levels to pilot or small commercial outputs. Lot records permit cross-checking and back-calculation if a scale-up reveals an unexpected process challenge.
Researchers running iterative screens—month after month—know the risks of switching suppliers or facing variable material. Consistent Unifiram lots reduce run-to-run drift, letting teams focus on experimental design, not patching up shifting material behavior. This reduces the number of failed project cycles and re-works, allowing more resources for meaningful advancement.
From the outset, we set out to minimize chemical waste and maximize energy efficiency. Our Unifiram production lines use closed-loop solvent recovery, drastically reducing disposal volumes. Routine environmental monitoring covers airborne emissions and soil contact at every plant interface. These choices stem not from compliance pressure, but from years of seeing the difference tight controls make in staff safety and community goodwill.
Major input solvents undergo purification and reuse, with real-time monitoring to spot any drift in contaminant levels or system wear. Filtration systems receive regular, hands-on cleaning—no shortcuts. Our view is that responsible manufacturing supports both researchers and downstream communities.
We believe real progress in the research chemicals sector means listening and iterating in collaboration with users. Each new lot of Unifiram results from post-market feedback and close attention to field experience. Practical tweaks—whether in crystal size or packaging—often arise from direct discussions with labs trying new delivery methods or analytical strategies.
We support open-access engagement. Our technical documentation, spectral libraries, and stability data grow with each production cycle, available for researchers who want to cross-verify or design more robust protocols. Peer exchange, not just internal validation, guides our thinking. Experienced chemists know that no product develops in isolation, especially at the cutting edge of neuropharmacology. We maintain direct channels for feedback and quick-turn solutions, supporting those forging new paths with Unifiram in their toolkit.
Every kilogram of Unifiram that leaves our factory represents years of cumulative knowledge and attention to detail—from the design of our distillation rigs to the quality checks on raw material. We stay committed to reliability, direct dialogue, and transparent processes that build trust across the research community. Our chemists, engineers, and product handlers keep eyes and hands on every shipment, aligning deliverables with the real needs of scientists using Unifiram as a dependable foundation in their work.