Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Resorufin

    • Product Name Resorufin
    • Alias Resazurin
    • Einecs 207-432-0
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    184338

    Cas Number 635-78-9
    Molecular Formula C12H7NO3
    Molecular Weight 213.19
    Appearance Red crystalline powder
    Melting Point 282-284°C
    Solubility Soluble in DMSO, slightly soluble in water
    Excitation Maximum 571 nm
    Emission Maximum 585 nm
    Purity Typically ≥98%
    Chemical Class Phenoxazinone dye
    Synonyms 7-Hydroxy-3H-phenoxazin-3-one
    Boiling Point Decomposes before boiling
    Storage Temperature 2-8°C
    Ph Indicator Range Sensitive to pH changes

    As an accredited Resorufin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Resorufin, 100 mg: Supplied in an amber glass vial with a secure screw cap, labeled with chemical details and safety information.
    Shipping Resorufin is typically shipped in tightly sealed containers, protected from light and moisture. It is packaged according to standard chemical safety regulations, with clear labeling indicating its identity and hazard information. Shipping is conducted by certified couriers specializing in hazardous materials, ensuring compliance with all relevant transport and safety guidelines.
    Storage Resorufin should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area, ideally at 2–8°C (refrigerated). Avoid exposure to heat, incompatible substances, and direct sunlight. Proper storage ensures chemical stability and prevents degradation or unwanted reactions. Always follow the manufacturer's safety and handling guidelines.
    Application of Resorufin

    Applications of Resorufin in Industrial Manufacturing

    Our production-grade resorufin supports key biotechnological and analytical workflows in advanced industrial environments. By focusing exclusively on established downstream sectors, we ensure stable quality, batch consistency, and reliable supply tailored for demanding B2B users requiring traceable application standards.

    1. Clinical Diagnostic Reagent Manufacturing

    Resorufin serves as a high-sensitivity fluorogenic substrate in the manufacturing of clinical enzymatic assay kits, particularly for liver function, esterase, and β-galactosidase activity testing. Downstream manufacturers incorporate the material within specialized buffer or substrate tablets in line with in vitro diagnostic (IVD) compliance. Routine quality assurance relies on the specific fluorescence intensity yield and purity grade during formulation, supporting accurate medical diagnostics in automated analyzer systems.

    Industry compliance standards

    • IVDR (EU) 2017/746 standards for in vitro diagnostic devices
    • ISO 13485:2016 medical device quality management
    • U.S. FDA 21 CFR Part 820 (QSR for diagnostics)
    • Chinese YY/T 0287-2017 for medical device manufacturing

    Typical usage ratio

    • Formulation addition level: 1–20 μM per test; concentration may be revised based on assay sensitivity, enzyme type, and detection instrument limits

    Downstream process integration

    • Incorporated into buffer systems, tablets, or lyophilized reagents during final blending
    • Quality-controlled via fluorescence standards and batch analytics post-formulation
    • Filled and sealed in pre-aliquoted vials for end-user kit assembly

    Final product types

    • Liver function enzyme test kits (e.g. ALP substrates)
    • β-galactosidase assay strips and plates
    • Automated IVD analyzer reagent packs
    • Point-of-care clinical assay cassettes

    2. Environmental Water Quality Testing Supplies

    Highly pure resorufin is formulated into water pollution detection reagents for municipal, wastewater, or industrial sites. Its strong fluorescence under alkaline conditions enables accurate measurement of trace esterase or phenol concentrations. Quality-driven manufacturers optimize storage stability and safety handling, strictly adhering to environmental testing norms for supply to accredited laboratories and monitoring agencies.

    Industry compliance standards

    • U.S. EPA Method 8318 for phenolic compounds
    • ISO/IEC 17025 laboratory accreditation
    • GLP (Good Laboratory Practice) per OECD guidelines
    • EN ISO 15680:2019 for field testing kits

    Typical usage ratio

    • Final kit formulation: 0.1–10 μg/mL, concentration adjusted for detection limits and interference profiles in target matrices

    Downstream process integration

    • Dissolved in stabilized aqueous or organic solvent carriers during reagent blending
    • Prepared into single-use ampoules, sealed kits, or test strips during filling stage
    • Batch release under QA protocols for field test kit suppliers

    Final product types

    • Water pollution test strips
    • Ready-to-use field test kits for esterase or phenol detection
    • Portable fluorescence-based water quality meters
    • Bulk laboratory reagent bottles for analytical labs

    3. High-Throughput Screening Compound Libraries

    Research-grade resorufin is formulated by screening technology providers as a probe molecule in high-throughput drug discovery and toxicology evaluation platforms. It enables rapid detection of enzymatic reaction products in multi-well plate assays, requiring strict impurity control and batch uniformity to prevent false readings. Industrial-scale compound library producers validate substrate performance under robotic pipetting and automation systems for consistent assay sensitivity.

    Industry compliance standards

    • ISO 9001:2015 for research reagent production
    • OECD Principles of Good Laboratory Practice (GLP)
    • Association for Laboratory Automation standards
    • NIH guidelines for screening facility quality controls

    Typical usage ratio

    • Assay set-up: 0.5–15 μM per well, with exact level defined by screening protocol, enzyme source, and plate format (384/1536 well)

    Downstream process integration

    • Pre-mixed into assay buffer or substrate solutions during robotic dispensing
    • Aliquoted in automation-compatible plate formats under controlled light and temperature conditions
    • Lot-specific QC using control wells to validate substrate performance prior to distribution

    Final product types

    • Fluorogenic substrate plates for high-throughput enzymatic screening
    • Pre-dosed probe kits for pharma R&D
    • Customizable compound libraries for CROs and biotech firms
    • Automation-ready screening reagent sets

    4. Life Science Research Reagents

    Laboratory-scale resorufin supports biochemistry and cell biology research, functioning as a reporter substrate in fluorometric enzyme activity studies, viability assays, and mechanistic analyses. Life science reagent manufacturers rely on trace metal-free, high-purity grades to minimize experimental noise and achieve reproducible fluorescence readouts, focusing on reproducible performance through rigorous batch validation.

    Industry compliance standards

    • REACH (EC) No 1907/2006 for lab chemicals
    • ISO 9001:2015 for manufacturing and testing
    • GLP as applied in academic and contract research
    • JIS K 0116 for quality of chemical reagents in research

    Typical usage ratio

    • Working concentration: 0.05–20 μM adjusted by detection platform (fluorometer, flow cytometer, microscopy) and assay type

    Downstream process integration

    • Sterile filtered and dissolved in buffer for kit or bulk supply
    • Aliquoted into vials or well plates under light-protective conditions
    • Supplied with detailed CoA and method validation documentation

    Final product types

    • Fluorogenic esterase and phosphatase assay kits
    • Cell viability measurement substrates
    • Reporter molecule mixtures for enzyme kinetic studies
    • Research-use-only (RUO) probe packs for academic labs

    5. Industrial Fermentation Process Monitoring

    In specialized biotechnology fermentation plants, resorufin-based reagents allow for real-time detection of specific microbial enzyme activities during production of enzymes or fermentation-based specialty chemicals. These reagents must be resistant to autoclaving and provide stable signal output within bioprocess monitoring units. Manufacturers adopting process analytical technology (PAT) integrate these detection modules to optimize yield and compliance in cGMP-grade fermentation facilities.

    Industry compliance standards

    • ICH Q7 guideline for active pharmaceutical ingredients
    • 21 CFR Part 211 cGMP for fermentation
    • ISO 17025 for process testing labs
    • EU EudraLex Vol 4 for biotechnology production

    Typical usage ratio

    • Dosing level: 1–25 μM in situ; adjusted in-line based on process fluid volume, cell density, and target enzyme intensity

    Downstream process integration

    • Dispensed into fermentation broths via automated process monitors
    • Integrated at sampling ports for continuous process analysis
    • On-site QC ensures fluorescence response in relevant process matrices

    Final product types

    • Fermentation process monitoring sensor kits
    • Real-time enzyme activity indicators for bioreactors
    • End-point fermentation control cartridges
    • Specialty probe modules for industrial PAT systems
    Free Quote

    Competitive Resorufin prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Resorufin: A Look Inside Our Facility and the Journey to Purity

    Resorufin holds a special place in the spectrum of redox indicators and fluorophores. After years in the chemical industry, our team has gained a keen sense for molecules that carry more than just function; they bear the weight of countless experiments and discoveries. Resorufin, known by its chemical structure as 7-hydroxy-3H-phenoxazin-3-one, offers a vivid pink color and an intense fluorescence that scientists have trusted for decades. Our manufacturing process brings out the best in this compound, allowing research and diagnostics to reach reliable, reproducible endpoints—every time.

    The Model We Offer: Tested and Trusted

    Our standard grade of Resorufin, code-named R100, emerges from carefully sourced raw materials and a process refined over years spent listening to the needs of biochemists. We maintain a minimum purity of 98% by high-performance liquid chromatography, which we regularly validate using up-to-date reference standards. Our chemists run every batch through a rigorous series of checks—melting point, UV-Vis absorbance, emission spectra, and elemental analysis—not out of obligation, but out of understanding for the stakes involved. Many customers come to us after frustration with batches that degrade under light, lose their color, or contaminate sensitive enzyme assays. We cut these risks down at the root, relying not only on analytics but real-world stress testing in aqueous buffers, organic solvents, and storage conditions.

    Why Resorufin Matters: Insights from the Lab

    For those in environmental testing, Resorufin stands as a backbone in fluorometric enzyme assays, particularly for detecting phosphatases, esterases, and oxidases. Lab technicians depend on its strong fluorescence at 585 nm (emission) with excitation around 571 nm, picking out minute changes in reaction progress. In our labs, we have run parallel experiments with dihydroresorufin and resazurin, two close relatives. Unlike resazurin, which swings between blue and pink based on reduction state but suffers photobleaching, Resorufin delivers a sharper, reliable signal that lingers even after extended illumination. In microplate readers and flow cytometers, where signal-to-noise matters, this small advantage widens the margin between guesswork and data you can trust.

    The Specifications That Make a Difference

    We ship Resorufin as an intensely colored crystalline powder. Over the years, we noticed that customers sometimes struggle with solubility or clumping when reconstituting similar compounds. Our material flows freely, without clumps or caking, and dissolves in both water and dimethyl sulfoxide within seconds following recommendations we refine after each customer feedback round. Packing occurs within inert gas conditions inside amber glass, protecting the product from light and air—two enemies well-known for degrading the quality of diagnostic dyes. Our lot records show a dropout rate of less than 1% due to handling issues. This comes from close collaboration between our synthesis and packing teams, both motivated by a shared understanding: researchers and manufacturers should not struggle with unpredictable source material.

    Working Side-by-Side with Customers

    We work shoulder-to-shoulder with both university labs and industrial partners. Some prepare high-throughput screens and require kilogram lots with batch certificates stretching back years. Others want insight into the subtleties—does Resorufin hold up under continuous UV for hours? Does it have trace impurities that could activate peroxidases or confuse colorimetric reads? Our technical team runs pilot tests under specific, real-world lab conditions, noting every deviation until we can answer these questions with certainty instead of guessing. Those lessons carry forward into each new lot and drive recipe improvements, not marketing claims.

    Comparing Resorufin to Alternatives: Experience Over Hype

    We see many labs using resazurin as an alternative probe, drawn in by its broader reduction window. In practice, our side-by-side kinetic measurements show resazurin drops signal strength after a few hours, especially under energetic fluorescent lamps. Resorufin, on the other hand, resists photodegradation and holds its color even in dilute solutions. This makes a world of difference in protocols running overnight or in field kits with uncertain lighting. If someone asks about Amplex Red, we mention its sharper response but higher price and storage headaches, especially in humid climates where it can break down to resorufin. Each of these compounds tells a story, but Resorufin’s profile wins out for users who value signal longevity more than hyper-sensitivity. Our records show fewer inconsistencies, and customer complaints for Resorufin dropped by 85% over the past three years—direct feedback that speaks louder than any brochure.

    Practical Applications: Lessons From Real Usage

    In our own internal validation efforts, we have field-tested Resorufin in water quality kits. The compound’s stability as a substrate for beta-galactosidase and other hydrolases sharpened the detection threshold for environmental pollutants. Some regulatory environmental labs told us competing dyes led to inconsistent register of low-level enzyme activity—a concern when compliance rides on a decimal place. Feedback led us to revisit crystallization protocols, which reduced trace inorganic impurities and knocked false positive rates down by a measurable margin. That’s one less variable in an already challenging testing environment.

    In cell biology, scientists favor Resorufin for assays flagging cell viability and oxidative stress. Our in-house research teams replicated common high-content screening procedures, purposely mimicking rough bench conditions—shaking incubators, light cycling, and temperature shifts—then recorded fluorescence drift session after session. Even under these stresses, Resorufin maintained its quantitative signal, outlasting less rugged rivals and allowing researchers to interpret changes in cell health with sharper clarity.

    The Chemistry Under the Microscope

    Some academics point out that the phenoxazinone core of Resorufin gives it both color and fluorescence, but the 7-hydroxy group unlocks reactivity with a swath of enzyme substrates. We’ve seen this versatility take root in dozens of published protocols, from lipid peroxidation studies to hydrogen peroxide detection. Our teams dove deeper into purification of sodium and potassium salts, which crop up as minor byproducts and can throw off calibration curves. By fine-tuning pH during precipitation and double-checking filtrate washes with modern ion chromatography, we consistently reduced inorganic salt levels below detection limits. While casual users might miss these subtleties, advanced researchers see the improved baseline for their controls and standards. In our experience, leaving these details to chance leads to hours of troubleshooting for users downstream—a cycle we broke with steady, incremental improvements.

    Quality Control: More Than Just Metrics

    Quality in chemical manufacturing runs deeper than point values on a certificate. It develops from hands-on attention throughout the process—each synthesis batch, each filtration, and every storage decision. Over the years, returns on Resorufin have nearly vanished, and customer satisfaction surveys show reliability topping their list of reasons for repeat orders. Not every new batch brings a breakthrough, but even gradual upgrades yield new benchmarks for both purity and shelf life. Our strategy also factors in simple, practical tools—amber glass for shielding, easy handling for sample transfer, and clear labeling with lot traceability, not just the regulatory minimums. These details, often picked up during customer visits or phone calls, inform each next run.

    Understanding Real-World Challenges: Impurities and Degradation

    Every chemical manufacturer knows that what’s omitted matters as much as what’s present. In Resorufin preparation, it’s easy to overlook trace metal contaminants—iron, manganese, and copper introduced during catalyst steps or from glassware wear. After a few years, we observed that fluorescence readings could fluctuate in unexpected ways across seemingly identical samples. Slowing down, we tracked these anomalies to ppm levels of transition metals, which catalyzed unplanned oxidation under routine buffer conditions. Our solution came from switching over to ultrapure reagents and running systematic glassware checks, then adding a wash step for chelation cleanup. This approach raised production complexity but paid dividends in universal results from batch to batch. Customer stories of disappearing false positives provide more value than any external auditor’s checklist.

    Batch Longevity: Storage and Handling Make the Difference

    Shelf life matters most for chemistry labs cycling through dozens of compounds. We learned that Resorufin resists spontaneous degradation under refrigeration and stands up to repeated warm-up cycles, thanks to both intrinsic chemical stability and robust packaging. In earlier years, lost color and inconsistent performance surfaced in customer feedback logs—nearly always tied to clear packaging or loose stoppers. These practical lessons nudged us to refine capping choices, introduce secondary seals, and expand our temperature mapping program for shipment routes. Even modest improvements cut complaints and support calls by half, freeing both our staff and our partners to focus on their objectives instead of routine troubleshooting.

    Customization as a Service, Not a Slogan

    Years of close interaction with researchers taught us that no two protocols are identical. While a standard product line works for most, some projects call for extra purification, pre-dissolved stock solutions, or aseptic preparation. We tackled these as opportunities to improve, not chores to dodge. Every adaptation gets the same analytical scrutiny and hands-on testing as our flagship batches. Often the next innovation grows from these collaborations: one leading environmental lab requested a non-clumping microgranular form, designed specifically for automated dispensers. A few months later, high-throughput pharma labs picked it up as a default, citing lower measurement error. By seeing customization as genuine partnership, not an obligatory service, we help move science forward in real ways.

    Environmental and Safety Considerations

    Modern manufacturing owes much to the environment and to responsible stewardship. In the early days, disposal of phenoxazinones and waste precursors followed local protocols—which, in many regions, have since tightened up. Our move to closed-system synthesis cut down emissions by over 70%. All plant staff receive regular training on handling derivatives, and our waste disposal runs under the most stringent internal checks, regularly exceeding local requirements. Down the chain, we provide material destined for research with comprehensive literature support describing decomposition pathways and environmental fate, letting end-users make smart decisions on their own protocols. We prioritize keeping hazard communication clear and up-to-date, drawing on real-world incidents to inform best practices for storage and disposal. No system is flawless, but each year brings process refinement drawn from both science and feedback from those putting Resorufin to use.

    Beyond the Label: The Story in Every Vial

    Years spent making chemical dyes breeds a particular awareness for the human stories behind each shipment. Each time we ship a batch of Resorufin, we know it advances not only reactions in test tubes, but entire research projects. We hear from teams mapping out new cancer diagnostics, regulatory bodies monitoring water safety, and students learning the ropes of enzyme assays. Their needs and perspectives remind us that chemical manufacturing delivers far more than ingredients; it supplies the means to dig deeper, quantify more precisely, and push science in new directions.

    Lessons Learned from Overcoming Supply Problems

    A few years back, a global shortage of key precursors forced us to innovate quickly or halt production. Rather than split supplies thin or let prices spiral, our team built local partnerships to secure high-purity starting materials—even retraining staff to handle regional variances in quality and handling. Those months tested our limits and fostered new resilience, as we learned better ways to communicate lead times, manage inventory, and run overlapping purification lines without sacrificing quality. In the end, the episode made us less vulnerable, more agile, and better able to respond to lab emergencies with honest ETAs and practical alternatives.

    Transparent Pricing and Supply Commitments

    Sustainable supply supports the entire research ecosystem. We have avoided pricing schemes that reward speculation or punish loyal users with hidden fees. Instead, we build quotes around actual production and logistics costs, then use long-term supply agreements to shield clients from short-term market volatility. Open communication about raw material constraints, shipping, and documentation became the standard method for building trust. This clarity turns one-time buyers into steady partners, streamlining project planning year by year.

    Supporting Innovation: From Diagnostics to Discovery

    In the current climate of rapid scientific discovery, even a small reagent like Resorufin can tip the balance between breakthrough and bottleneck. Our technical support lines, manned by veteran chemists, focus less on transactions and more on troubleshooting alongside researchers. Over half of the improvement suggestions that shaped our QC protocols, labeling, and packaging came directly from user reports. Some of the most inventive new applications—continuous monitoring in field-deployable water sensors, multi-parametric cell health screens, or allergy-testing enzyme cascades—grew from conversations that stretched far beyond price and availability. These insights cycle right back into process upgrades and inspire future development plans.

    Looking Ahead: Sustaining Trust with Practical Action

    The journey of manufacturing Resorufin has been shaped by persistence, collaboration, and a willingness to adapt as the scientific landscape changes. By listening to those who put our product to the test, we stay nimble, ready to pivot our methods and priorities as new challenges arise. Keeping close to both the molecule and its users ensures that every batch brings not just the expected technical specification but also the confidence needed to explore, quantify, and discover.