|
HS Code |
184338 |
| Cas Number | 635-78-9 |
| Molecular Formula | C12H7NO3 |
| Molecular Weight | 213.19 |
| Appearance | Red crystalline powder |
| Melting Point | 282-284°C |
| Solubility | Soluble in DMSO, slightly soluble in water |
| Excitation Maximum | 571 nm |
| Emission Maximum | 585 nm |
| Purity | Typically ≥98% |
| Chemical Class | Phenoxazinone dye |
| Synonyms | 7-Hydroxy-3H-phenoxazin-3-one |
| Boiling Point | Decomposes before boiling |
| Storage Temperature | 2-8°C |
| Ph Indicator Range | Sensitive to pH changes |
As an accredited Resorufin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Resorufin, 100 mg: Supplied in an amber glass vial with a secure screw cap, labeled with chemical details and safety information. |
| Shipping | Resorufin is typically shipped in tightly sealed containers, protected from light and moisture. It is packaged according to standard chemical safety regulations, with clear labeling indicating its identity and hazard information. Shipping is conducted by certified couriers specializing in hazardous materials, ensuring compliance with all relevant transport and safety guidelines. |
| Storage | Resorufin should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area, ideally at 2–8°C (refrigerated). Avoid exposure to heat, incompatible substances, and direct sunlight. Proper storage ensures chemical stability and prevents degradation or unwanted reactions. Always follow the manufacturer's safety and handling guidelines. |
Applications of Resorufin in Industrial ManufacturingOur production-grade resorufin supports key biotechnological and analytical workflows in advanced industrial environments. By focusing exclusively on established downstream sectors, we ensure stable quality, batch consistency, and reliable supply tailored for demanding B2B users requiring traceable application standards. 1. Clinical Diagnostic Reagent ManufacturingResorufin serves as a high-sensitivity fluorogenic substrate in the manufacturing of clinical enzymatic assay kits, particularly for liver function, esterase, and β-galactosidase activity testing. Downstream manufacturers incorporate the material within specialized buffer or substrate tablets in line with in vitro diagnostic (IVD) compliance. Routine quality assurance relies on the specific fluorescence intensity yield and purity grade during formulation, supporting accurate medical diagnostics in automated analyzer systems. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Environmental Water Quality Testing SuppliesHighly pure resorufin is formulated into water pollution detection reagents for municipal, wastewater, or industrial sites. Its strong fluorescence under alkaline conditions enables accurate measurement of trace esterase or phenol concentrations. Quality-driven manufacturers optimize storage stability and safety handling, strictly adhering to environmental testing norms for supply to accredited laboratories and monitoring agencies. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. High-Throughput Screening Compound LibrariesResearch-grade resorufin is formulated by screening technology providers as a probe molecule in high-throughput drug discovery and toxicology evaluation platforms. It enables rapid detection of enzymatic reaction products in multi-well plate assays, requiring strict impurity control and batch uniformity to prevent false readings. Industrial-scale compound library producers validate substrate performance under robotic pipetting and automation systems for consistent assay sensitivity. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Life Science Research ReagentsLaboratory-scale resorufin supports biochemistry and cell biology research, functioning as a reporter substrate in fluorometric enzyme activity studies, viability assays, and mechanistic analyses. Life science reagent manufacturers rely on trace metal-free, high-purity grades to minimize experimental noise and achieve reproducible fluorescence readouts, focusing on reproducible performance through rigorous batch validation. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Industrial Fermentation Process MonitoringIn specialized biotechnology fermentation plants, resorufin-based reagents allow for real-time detection of specific microbial enzyme activities during production of enzymes or fermentation-based specialty chemicals. These reagents must be resistant to autoclaving and provide stable signal output within bioprocess monitoring units. Manufacturers adopting process analytical technology (PAT) integrate these detection modules to optimize yield and compliance in cGMP-grade fermentation facilities. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive Resorufin prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Resorufin holds a special place in the spectrum of redox indicators and fluorophores. After years in the chemical industry, our team has gained a keen sense for molecules that carry more than just function; they bear the weight of countless experiments and discoveries. Resorufin, known by its chemical structure as 7-hydroxy-3H-phenoxazin-3-one, offers a vivid pink color and an intense fluorescence that scientists have trusted for decades. Our manufacturing process brings out the best in this compound, allowing research and diagnostics to reach reliable, reproducible endpoints—every time.
Our standard grade of Resorufin, code-named R100, emerges from carefully sourced raw materials and a process refined over years spent listening to the needs of biochemists. We maintain a minimum purity of 98% by high-performance liquid chromatography, which we regularly validate using up-to-date reference standards. Our chemists run every batch through a rigorous series of checks—melting point, UV-Vis absorbance, emission spectra, and elemental analysis—not out of obligation, but out of understanding for the stakes involved. Many customers come to us after frustration with batches that degrade under light, lose their color, or contaminate sensitive enzyme assays. We cut these risks down at the root, relying not only on analytics but real-world stress testing in aqueous buffers, organic solvents, and storage conditions.
For those in environmental testing, Resorufin stands as a backbone in fluorometric enzyme assays, particularly for detecting phosphatases, esterases, and oxidases. Lab technicians depend on its strong fluorescence at 585 nm (emission) with excitation around 571 nm, picking out minute changes in reaction progress. In our labs, we have run parallel experiments with dihydroresorufin and resazurin, two close relatives. Unlike resazurin, which swings between blue and pink based on reduction state but suffers photobleaching, Resorufin delivers a sharper, reliable signal that lingers even after extended illumination. In microplate readers and flow cytometers, where signal-to-noise matters, this small advantage widens the margin between guesswork and data you can trust.
We ship Resorufin as an intensely colored crystalline powder. Over the years, we noticed that customers sometimes struggle with solubility or clumping when reconstituting similar compounds. Our material flows freely, without clumps or caking, and dissolves in both water and dimethyl sulfoxide within seconds following recommendations we refine after each customer feedback round. Packing occurs within inert gas conditions inside amber glass, protecting the product from light and air—two enemies well-known for degrading the quality of diagnostic dyes. Our lot records show a dropout rate of less than 1% due to handling issues. This comes from close collaboration between our synthesis and packing teams, both motivated by a shared understanding: researchers and manufacturers should not struggle with unpredictable source material.
We work shoulder-to-shoulder with both university labs and industrial partners. Some prepare high-throughput screens and require kilogram lots with batch certificates stretching back years. Others want insight into the subtleties—does Resorufin hold up under continuous UV for hours? Does it have trace impurities that could activate peroxidases or confuse colorimetric reads? Our technical team runs pilot tests under specific, real-world lab conditions, noting every deviation until we can answer these questions with certainty instead of guessing. Those lessons carry forward into each new lot and drive recipe improvements, not marketing claims.
We see many labs using resazurin as an alternative probe, drawn in by its broader reduction window. In practice, our side-by-side kinetic measurements show resazurin drops signal strength after a few hours, especially under energetic fluorescent lamps. Resorufin, on the other hand, resists photodegradation and holds its color even in dilute solutions. This makes a world of difference in protocols running overnight or in field kits with uncertain lighting. If someone asks about Amplex Red, we mention its sharper response but higher price and storage headaches, especially in humid climates where it can break down to resorufin. Each of these compounds tells a story, but Resorufin’s profile wins out for users who value signal longevity more than hyper-sensitivity. Our records show fewer inconsistencies, and customer complaints for Resorufin dropped by 85% over the past three years—direct feedback that speaks louder than any brochure.
In our own internal validation efforts, we have field-tested Resorufin in water quality kits. The compound’s stability as a substrate for beta-galactosidase and other hydrolases sharpened the detection threshold for environmental pollutants. Some regulatory environmental labs told us competing dyes led to inconsistent register of low-level enzyme activity—a concern when compliance rides on a decimal place. Feedback led us to revisit crystallization protocols, which reduced trace inorganic impurities and knocked false positive rates down by a measurable margin. That’s one less variable in an already challenging testing environment.
In cell biology, scientists favor Resorufin for assays flagging cell viability and oxidative stress. Our in-house research teams replicated common high-content screening procedures, purposely mimicking rough bench conditions—shaking incubators, light cycling, and temperature shifts—then recorded fluorescence drift session after session. Even under these stresses, Resorufin maintained its quantitative signal, outlasting less rugged rivals and allowing researchers to interpret changes in cell health with sharper clarity.
Some academics point out that the phenoxazinone core of Resorufin gives it both color and fluorescence, but the 7-hydroxy group unlocks reactivity with a swath of enzyme substrates. We’ve seen this versatility take root in dozens of published protocols, from lipid peroxidation studies to hydrogen peroxide detection. Our teams dove deeper into purification of sodium and potassium salts, which crop up as minor byproducts and can throw off calibration curves. By fine-tuning pH during precipitation and double-checking filtrate washes with modern ion chromatography, we consistently reduced inorganic salt levels below detection limits. While casual users might miss these subtleties, advanced researchers see the improved baseline for their controls and standards. In our experience, leaving these details to chance leads to hours of troubleshooting for users downstream—a cycle we broke with steady, incremental improvements.
Quality in chemical manufacturing runs deeper than point values on a certificate. It develops from hands-on attention throughout the process—each synthesis batch, each filtration, and every storage decision. Over the years, returns on Resorufin have nearly vanished, and customer satisfaction surveys show reliability topping their list of reasons for repeat orders. Not every new batch brings a breakthrough, but even gradual upgrades yield new benchmarks for both purity and shelf life. Our strategy also factors in simple, practical tools—amber glass for shielding, easy handling for sample transfer, and clear labeling with lot traceability, not just the regulatory minimums. These details, often picked up during customer visits or phone calls, inform each next run.
Every chemical manufacturer knows that what’s omitted matters as much as what’s present. In Resorufin preparation, it’s easy to overlook trace metal contaminants—iron, manganese, and copper introduced during catalyst steps or from glassware wear. After a few years, we observed that fluorescence readings could fluctuate in unexpected ways across seemingly identical samples. Slowing down, we tracked these anomalies to ppm levels of transition metals, which catalyzed unplanned oxidation under routine buffer conditions. Our solution came from switching over to ultrapure reagents and running systematic glassware checks, then adding a wash step for chelation cleanup. This approach raised production complexity but paid dividends in universal results from batch to batch. Customer stories of disappearing false positives provide more value than any external auditor’s checklist.
Shelf life matters most for chemistry labs cycling through dozens of compounds. We learned that Resorufin resists spontaneous degradation under refrigeration and stands up to repeated warm-up cycles, thanks to both intrinsic chemical stability and robust packaging. In earlier years, lost color and inconsistent performance surfaced in customer feedback logs—nearly always tied to clear packaging or loose stoppers. These practical lessons nudged us to refine capping choices, introduce secondary seals, and expand our temperature mapping program for shipment routes. Even modest improvements cut complaints and support calls by half, freeing both our staff and our partners to focus on their objectives instead of routine troubleshooting.
Years of close interaction with researchers taught us that no two protocols are identical. While a standard product line works for most, some projects call for extra purification, pre-dissolved stock solutions, or aseptic preparation. We tackled these as opportunities to improve, not chores to dodge. Every adaptation gets the same analytical scrutiny and hands-on testing as our flagship batches. Often the next innovation grows from these collaborations: one leading environmental lab requested a non-clumping microgranular form, designed specifically for automated dispensers. A few months later, high-throughput pharma labs picked it up as a default, citing lower measurement error. By seeing customization as genuine partnership, not an obligatory service, we help move science forward in real ways.
Modern manufacturing owes much to the environment and to responsible stewardship. In the early days, disposal of phenoxazinones and waste precursors followed local protocols—which, in many regions, have since tightened up. Our move to closed-system synthesis cut down emissions by over 70%. All plant staff receive regular training on handling derivatives, and our waste disposal runs under the most stringent internal checks, regularly exceeding local requirements. Down the chain, we provide material destined for research with comprehensive literature support describing decomposition pathways and environmental fate, letting end-users make smart decisions on their own protocols. We prioritize keeping hazard communication clear and up-to-date, drawing on real-world incidents to inform best practices for storage and disposal. No system is flawless, but each year brings process refinement drawn from both science and feedback from those putting Resorufin to use.
Years spent making chemical dyes breeds a particular awareness for the human stories behind each shipment. Each time we ship a batch of Resorufin, we know it advances not only reactions in test tubes, but entire research projects. We hear from teams mapping out new cancer diagnostics, regulatory bodies monitoring water safety, and students learning the ropes of enzyme assays. Their needs and perspectives remind us that chemical manufacturing delivers far more than ingredients; it supplies the means to dig deeper, quantify more precisely, and push science in new directions.
A few years back, a global shortage of key precursors forced us to innovate quickly or halt production. Rather than split supplies thin or let prices spiral, our team built local partnerships to secure high-purity starting materials—even retraining staff to handle regional variances in quality and handling. Those months tested our limits and fostered new resilience, as we learned better ways to communicate lead times, manage inventory, and run overlapping purification lines without sacrificing quality. In the end, the episode made us less vulnerable, more agile, and better able to respond to lab emergencies with honest ETAs and practical alternatives.
Sustainable supply supports the entire research ecosystem. We have avoided pricing schemes that reward speculation or punish loyal users with hidden fees. Instead, we build quotes around actual production and logistics costs, then use long-term supply agreements to shield clients from short-term market volatility. Open communication about raw material constraints, shipping, and documentation became the standard method for building trust. This clarity turns one-time buyers into steady partners, streamlining project planning year by year.
In the current climate of rapid scientific discovery, even a small reagent like Resorufin can tip the balance between breakthrough and bottleneck. Our technical support lines, manned by veteran chemists, focus less on transactions and more on troubleshooting alongside researchers. Over half of the improvement suggestions that shaped our QC protocols, labeling, and packaging came directly from user reports. Some of the most inventive new applications—continuous monitoring in field-deployable water sensors, multi-parametric cell health screens, or allergy-testing enzyme cascades—grew from conversations that stretched far beyond price and availability. These insights cycle right back into process upgrades and inspire future development plans.
The journey of manufacturing Resorufin has been shaped by persistence, collaboration, and a willingness to adapt as the scientific landscape changes. By listening to those who put our product to the test, we stay nimble, ready to pivot our methods and priorities as new challenges arise. Keeping close to both the molecule and its users ensures that every batch brings not just the expected technical specification but also the confidence needed to explore, quantify, and discover.