HS Code |
102672 |
| Chemicalname | N,N-Diethyl-1,4-Phenylenediamine |
| Casnumber | 93-05-0 |
| Molecularformula | C10H16N2 |
| Molecularweight | 164.25 g/mol |
| Appearance | White to reddish crystalline solid |
| Meltingpoint | 48-52°C |
| Boilingpoint | 146-148°C at 16 mmHg |
| Solubility | Soluble in water and ethanol |
| Density | 1.02 g/cm³ |
| Odor | Amine-like |
| Ph | Basic, forms slightly alkaline solutions |
| Logp | 2.02 |
| Synonyms | N,N-Diethyl-p-phenylenediamine; DPD |
As an accredited N,N-Diethyl-1,4-Phenylenediamine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Brown glass bottle, tightly sealed, labeled with chemical name and hazard warnings. Contains 100 grams of N,N-Diethyl-1,4-Phenylenediamine. |
| Shipping | Shipping of N,N-Diethyl-1,4-Phenylenediamine should comply with applicable chemical transport regulations. The substance must be packed securely in tightly sealed, appropriately labeled containers, protected from moisture, heat, and incompatible materials. Shipping documentation should include hazard information, and personnel handling the shipment must use suitable protective equipment to ensure safe transport. |
| Storage | N,N-Diethyl-1,4-Phenylenediamine should be stored in a cool, dry, and well-ventilated area, away from heat, sparks, and open flame. Keep the container tightly closed and protected from light and moisture. Store separately from oxidizing agents and strong acids. Clearly label the container and ensure access is restricted to trained personnel. Handle with appropriate personal protective equipment. |
Applications of N,N-Diethyl-1,4-Phenylenediamine in Industrial ManufacturingN,N-Diethyl-1,4-Phenylenediamine serves as a specialty intermediate in select chemical manufacturing industries where its reactivity and performance characteristics support high-value product applications. Below we detail confirmed commercial use cases across multiple sectors, based on our direct supply to global manufacturers. 1. Analytical Reagents for Water Quality TestingThis compound is a critical raw material for formulating colorimetric reagents used in water analysis kits. Water treatment labs and environmental monitoring agencies use its stabilized salt forms in tests that determine chlorine concentration via the DPD (N,N-Diethyl-p-phenylenediamine) method. Purity and batch consistency are crucial for precise color development. Formulators usually blend this diamine with buffers and stabilizers in powder or tablet form, adjusting ratios based on the targeted measurement range and test method (free chlorine, total chlorine, chloramine detection). Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Dye and Pigment Intermediate ManufacturingAs a key aromatic amine, N,N-Diethyl-1,4-Phenylenediamine acts as a building block for synthesis of certain azo dyes and oxidative dye precursors. Dye manufacturers utilize its high purity grade in multi-step batch processes, where it undergoes controlled coupling with diazonium salts to produce vivid, stable coloring agents. Quality control focuses on trace impurity levels to prevent side reactions or unwanted by-product coloration, impacting textile and ink performance. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Polymerization Inhibitor and Stabilizer ProductionPolymer resin manufacturers use this diamine as an antioxidant and radical scavenger to formulate inhibitors that extend monomer shelf life or protect finished polymers from oxidative degradation. The compound’s reactivity profile supports the stabilization of acrylics, styrenics, and certain polyurethanes. Integration requires adherence to process safety standards, especially when combined with peroxides or other initiators in bulk storage and transport. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Photographic Chemical FormulationsPhoto industry suppliers employ this compound as a core reactant in color developer solutions for traditional photographic processing. The diamine’s pure form enables controlled oxidation during film or print development, yielding consistent tone and image clarity. Production batches must meet analytical assay specifications for photographic grade purity and minimize trace metals or reducing substances. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Diagnostic Reagent Synthesis for Clinical ChemistryMedical diagnostics manufacturers select this aromatic diamine as an active ingredient in enzyme-based analytical reagent kits. It acts as a chromogenic substrate forming measurable color in clinical tests, including certain hemoglobin or hydrogen peroxide assays. Stringent quality agreements require traceability, validated absence of interfering substances, and verification according to pharmacopoeial guidelines. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive N,N-Diethyl-1,4-Phenylenediamine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Manufacturing chemicals isn’t just a job for us—it’s a commitment that stems from understanding what goes on between batch steps, sacks of raw materials, and the demands of the various end-users who rely on us for consistency and quality. N,N-Diethyl-1,4-Phenylenediamine (CAS: 93-05-0), often called DPDA or DPD, finds its way into water analysis labs across the globe, serving a critical role that many industries could barely imagine doing without. Our decision to produce it in-house wasn’t born out of guesswork or hearsay, but rather on years of working hand-in-hand with water treatment specialists, research chemists, and quality managers who require not just purity, but the assurance of unbroken supply and reliable performance.
We don’t just repack drums coming from somewhere else and slap a sticker on the barrel. Every batch runs through our reactors and gets sampled by our own team. We use raw materials with established provenance, tracking lot numbers and documenting processing conditions from start to finish. This level of control means we catch slight color changes or trace impurities before they reach your equipment, because these small variances can dramatically alter test results. With a product like N,N-Diethyl-1,4-Phenylenediamine, especially in applications such as chlorine analysis, those differences make or break the accuracy of the DPD method. Precision isn’t a buzzword around here—it’s a requirement.
Handling the synthesis of N,N-Diethyl-1,4-Phenylenediamine takes more than technical skill. It takes the patience to make incremental changes, optimize reaction conditions, and resist the urge to cut corners. The molecule looks simple on paper—C10H16N2, aromatic ring, with amine groups para to one another and both substituted with ethyls. The reality on the production floor tells a different story. Even small shifts in temperature or pH during synthesis impact crystal structure and purity outcomes. We’ve learned this firsthand by keeping our process adjustments and outcomes logged, so each operator working a shift knows the difference between a routine run and one that could go sideways.
Our dedicated analytical team tests and certifies each batch. Quality checks rely mostly on UV-vis spectrometry, HPLC, and sometimes NMR, with reference standards sourced from trusted partners. This attention to analytical verification appeals particularly to customers who need trace-level reliability. In our experience, those who come from industries like water treatment, photometry, or textile processing notice the difference between material made by a manufacturer invested in the process and anonymous product commissioned from brokers or resellers.
We learned long ago that water utility operators, environmental researchers, or even contract analytical service providers don’t want surprises from their reagents. Nobody wants to recalibrate an entire set of photometers because a new tub of DPD reacts two shades lighter or darker. Our production protocols follow methods developed in collaboration with veteran chemists and real-world customers. Over the years, we standardized batch records, trained operators to spot off-spec intermediary, and invested in in-line analytics. All this to avoid the customer ever seeing those inconsistencies.
In practical terms, a lab bench technician can open our tub and know that last month’s results will match the current batch. Delivering that kind of trust requires deeper engagement than box-ticking audits or one-time certifications. We audit ourselves continuously—qualifying raw materials, validating cleaning procedures, tracking every bag out the door. If a customer calls with a technical question or an issue comes up in their end-use testing, we don’t send them to a help desk—we put them directly in touch with the chemist responsible for the batch.
We blend our process chemistry with market understanding. Specifications for N,N-Diethyl-1,4-Phenylenediamine differ by sector. Water testing customers often require a powder with high solubility and low background absorbance, since even a faint trace of colored impurity or poorly filtered solid can skew chlorine readings. Our standard offering prepares as fine, off-white crystalline powder, because we know that too much yellow or brown tint prompts rejections in sensitive colorimetric use. For certain photometric applications, customers look for a defined particle size so the powder dissolves rapidly and completely, avoiding clump formation in solution.
We keep heavy metal content under strict control, using only corrosion-resistant processing equipment. This precaution reduces cross-contamination. Each product container sports a batch number, packing date, and, where relevant, fits packaging into tamper-evident formats. For bulk shipments, lined drums or moisture-barrier bags block water uptake, preventing caking while in storage. Such packing doesn’t come from a catalog of options, but from years of feedback from users wrestling with humidity, exposure, and handling losses.
Our staff doesn’t just see DPD as a theoretical molecule, but as a workhorse in commercial and municipal labs. Our conversations with water quality professionals and field technicians shaped the routines behind each pack we supply. From tap water evaluation to swimming pool maintenance, DPD stands as a mainstay for free and total chlorine measurement. We’ve followed regulatory guidelines for reagent specification, spent time with photometric methods based on EPA and ISO standards, and even hosted site visits from customer labs vetting our facilities before approving our product for procurement.
Beyond chlorine testing, some clients pull our DPD for textile dye analysis or for use in oxidant screening in chemical production. Our plant engineers once fielded technical queries from a mining operation seeking to understand how our DPD held up against trace metal contamination. These hands-on, solution-oriented discussions have shaped how we refine post-processing steps, rinsing parameters, and storage procedures. When labs report an unusual result, we don’t read from a script—we dive into process logs, assay data, and sometimes even pull reserve samples for side-by-side comparison.
Anyone can claim to supply DPD. What our years in chemical manufacturing have taught us is that purity is only the surface. True value lies in traceability, reliability, and openness to feedback. Where others focus on maximizing profit by shaving off production steps or outsourcing synthesis, we direct our investment toward tighter process controls, training staff on the nuances of amine chemistry, and building long-term relationships with end-users and inspection agencies.
One big difference comes from the transparency we offer. Whether a customer requests a certificate of analysis, needs documentation on trace metals, or wants to inspect standardized test data, we open the records. Most resellers can tell you about their latest shipment; few can explain why a certain lot achieves a cleaner baseline absorbance or maintains stability for extended storage. We welcome those who want to know how raw inputs impact purity, or who want updated stability studies to back up their choice for a new procurement round.
Across our history, we’ve sampled DPD from a wide range of sources as part of a constant benchmarking routine. Occasionally, we encounter sources where bulk stock has foreign odor, greater tendency to tan, or slow dissolving rates in water. These subtle differences result from minute process deviations—choice of solvent, reaction times, quench method, or filtration setups. If a competitor’s DPD takes longer to dissolve or smells off, it points directly to uncontrolled synthesis variables or improper drying. High impurity content shows up as color drift in photometric applications. We’ve been able to avoid these pitfalls by maintaining a batch-specific tracking system, allowing for targeted root cause investigation when any anomaly arises.
Comparing operator feedback on real-world test bench experience means more than just chasing purity figures. We’ve delivered to hundreds of quality control teams who can immediately spot the improvement in repeatability and clarity when they replace inconsistent material. Our plant teams share regular updates on production runs, and we incorporate user suggestions back into our SOPs, so the person running tests in the field ends up with a powder that dissolves the way it should and remains consistent week after week.
The journey from bench-scale synthesis to full-scale production isn’t finished just because the product appears on a datasheet. In our line of work, keeping a finger on industry feedback and international standards remains part of daily routine. We retain detailed logs on each process adjustment and record why alterations worked or failed, whether tweaking crystal growth conditions or streamlining final drying steps. Every incident report—from discoloration concerns to background interference in chlorine detection—feeds back into our review cycle. This system improves response for all customers, not just the one who reported a particular issue.
New analytical techniques and customer applications keep us updating our own standards. When a customer proposes a tighter allowable tolerance, our technical managers check feasibility and initiate validation trials. Sometimes, we end up shifting a part of the protocol or upgrading instrumentation. Because we control the setup, we can make such improvements internally, without delays from contract labs or outside processors. Keeping production strictly under our own roof lets us respond quickly to evolving client needs, compliance requirements, or market shifts. Our aim is to serve with evidence-based adjustments driven by actual results, not marketing blurbs.
Manufacturing DPD with attention to safety and regulatory norms isn’t optional. The aromatic amine structure, though favored for its robust reactivity, carries handling risks if process hygiene slips. Our facility operates within local, state, and international chemical handling rules. Operators suit up for material transfer, ventilation systems run during synthesis, and spill control protocols engage if monitoring equipment flags unusual readings. We document incidents, track exposure levels, and update our staff on control measures regularly. Our intention here is not only risk reduction for our own personnel, but to pass along peace of mind to those who depend on us for clean, non-contaminated stock.
For buyers in the water treatment field, regulatory scrutiny doesn’t end at the plant gate; routine audits and compliance checks extend into their labs and sometimes all the way to the public served by water utilities. Providing documentation or product samples that stand up to these checks brings a real-world benefit. We bring this level of attention because we’ve seen the costs, both financial and reputational, when a product fails in use and corrective measures roll in. Prevention on the production line beats correction in the field every time.
Building reliability into a specialty chemical supply chain starts with knowing how vulnerable each critical step becomes under changing market conditions. Global events can squeeze access to precursors or specialty packaging. By holding key raw materials in reserve and setting up redundancy in approved suppliers, we defend against shipping delays or price volatility. Our direct relationships with key input providers allow us to verify each raw chemical’s integrity, so downstream purification and conversion steps don’t suffer from hidden contaminants.
Once, a global shortage of an amine precursor forced us to find new partners on short notice. By dedicating part of our workforce to source validation and rapid analytical checks—even running multiple pilot syntheses across candidate vendors—we kept the supply running. Experiences like these taught us that quick response and hands-on engineering beat paperwork layer after paperwork layer. This same proactive mentality filters down to the operators and packers who see it as their own responsibility to report problems and suggest fixes—long before issues could ever hit a customer’s bench.
We treat service as a two-way street, not a scripted transaction. Our technical team speaks directly with end users, because only then do we hear about issues not visible from the production line. We encourage field technicians, QC analysts, and lab managers to call in when a variable arises—even if it’s outside standard specification. If necessary, we can pull archive samples for parallel analysis and issue rapid reports. We view these interactions as a source of innovation, with informed customers helping guide gradual process improvements.
Our site tours, open audits, and close technical cooperation with client labs allow for candid feedback. We take pride in hosting customers for process walkthroughs, sharing not just shiny finished product but also highlighting the rigorous cleaning, monitoring, and changeover procedures between batches. Seeing the plant in operation is the quickest way for a buyer or evaluator to appreciate which aspects differentiate a manufacturer from a trading operation.
Supplying N,N-Diethyl-1,4-Phenylenediamine involves more than ferrying dry chemicals from one warehouse to another. Over time, our entire team—chemists, shift operators, analysts, packers, technical managers—have seen first-hand that creating a trustworthy reagent starts with getting the fundamentals right. Reliable access to high-quality chemical inputs, tight process verification, deep batch-specific traceability, and direct communication remain cornerstones of our approach. It’s not about cutting costs or chasing higher volumes, but doing the work carefully, open to continuous improvement, and always listening to those who use our product daily.
When clients stake their own results, professional reputation, and regulatory compliance on the material we deliver, we take their trust seriously. Our DPD powder doesn’t just move from pallet to instrument; it carries thousands of validation hours, feedback loops, and hands-on experience built right into each container. We look forward to keeping up this standard, welcoming the next questions from the lab bench, and remaining the reliable partner our customers have come to depend on.