HS Code |
902726 |
| Product Name | H-Ala-Pna HCl |
| Formula | C10H13ClN4O2 |
| Molecular Weight | 272.69 g/mol |
| Synonyms | L-Alanyl-p-nitroanilide hydrochloride |
| Appearance | White to off-white powder |
| Solubility | Soluble in water |
| Purity | ≥98% |
| Storage Temperature | 2-8°C |
| Cas Number | 3406-11-9 |
| Usage | Chromogenic substrate for protease activity assays |
| Inchi Key | JZEKWINIODKXAA-UHFFFAOYSA-N |
| Smiles | CC(C(=O)N)NC(=O)C1=CC=C(C=C1)[N+](=O)[O-].Cl |
| Melting Point | 221-225°C (dec.) |
| Ph | Neutral (when dissolved in water) |
| Hazard Statements | Irritant |
As an accredited H-Ala-Pna Hcl factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The H-Ala-Pna HCl is supplied in a tightly sealed amber glass vial, containing 100 mg of white to off-white powder. |
| Shipping | H-Ala-Pna HCl is shipped in a tightly sealed container to ensure stability and prevent contamination. It is transported under ambient or controlled temperature conditions, as recommended by chemical safety guidelines. Proper labeling and documentation accompany the shipment to comply with regulatory requirements and guarantee safe and secure delivery. |
| Storage | H-Ala-Pna HCl should be stored in a cool, dry place, protected from light and moisture. Keep it tightly sealed in its original container at 2–8°C (refrigerated) to maintain stability. Avoid freezing and exposure to air. Handle using appropriate protective equipment in a well-ventilated area. Store away from incompatible substances and keep out of reach of unauthorized personnel. |
Applications of H-Ala-Pna HCl in Industrial ManufacturingH-Ala-Pna HCl, an essential peptide substrate, plays a definitive role in multiple industrial segments where specific enzymatic interactions are critical to product performance, regulatory compliance, and consistent batch outcomes. The following sections detail its principal downstream applications in biochemical manufacturing, clinical diagnostics, pharmaceutical research, and food quality analysis. 1. Protease Activity Assays in Biomedical Enzyme ManufacturingEnzyme manufacturers depend on H-Ala-Pna HCl to quantify and validate serine protease activity. The substrate’s unique structure ensures rapid and measurable hydrolysis, providing sensitive calibration for trypsin, chymotrypsin, and other serine protease assays. Operators must maintain GMP-compliant handling to reduce any trace contamination, ensuring accuracy for end-use enzyme product release testing. H-Ala-Pna HCl typically dissolves directly in buffer prior to use, staged for integration into automated workflow analyzers. Manufacturers design specifications based on defined kinetic parameters, optimizing both throughput and traceability. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Chromogenic Assay Kits for Clinical DiagnosticsClinical laboratories utilize H-Ala-Pna HCl as a chromogenic substrate in diagnostic assays to determine plasma and serum protease activity, with a focus on disorders related to coagulation and trypsin-like activity. Kit assemblers must source GMP-grade material to meet ISO and IVDR requirements for in vitro diagnostics. Substrate handling and aliquoting procedures minimize degradation risks, influencing both kit stability and shelf life. These chromogenic assays serve a critical function in routine patient testing and specialty disorder panels. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Biopharmaceutical Research and Peptide MappingPharmaceutical development teams leverage H-Ala-Pna HCl for precise peptide mapping and to calibrate enzyme inhibitors during early-stage drug research. Its role in substrate-specific assays allows accurate kinetic profiling of novel biologic entities, directly influencing lead candidate selection and structure-effect studies. Strict adherence to cGMP and regulatory guidelines ensures all reagents qualify for downstream process development, batch release, and regulatory submissions. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Enzymatic Food Testing and Quality ControlFood safety laboratories and quality assurance teams use H-Ala-Pna HCl in enzymatic tests to evaluate protease levels in food and ingredient batches, especially for dairy and processed meat sectors. The substrate’s rapid chromogenic response supports real-time monitoring of protease-induced spoilage or adulteration. Compliance with local and international food additive standards is mandatory during use, with traceability for all assay stages. Product formulation adapts the substrate dosage to match sample matrix complexity and regulatory reporting limits. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive H-Ala-Pna Hcl prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
At our facility, every batch of H-Ala-Pna HCl starts with close attention to both the chemistry and the process. H-Ala-Pna HCl, known among peptide chemists for its N-terminal alanine and a para-nitroanilide group, has found solid ground in the toolbox of anyone working with protease assays and sequence-specific proteolytic studies. We understand the push for cleaner, more reliable chromogenic substrates. In day-to-day work, this means delivering a crystalline, consistently pure compound that supports precise and repeatable enzyme kinetics.
Demand for H-Ala-Pna HCl really comes from its clarity and speed in enzyme substrate assays. We've seen how rapid color development matters in screening and quantifying peptidase activity. Peptide researchers keep coming back for a product that liberates p-nitroaniline with strong absorption at 405 nm, making results visible and measurable fast. We find that reliable physical and chemical specs alone don’t cut it. It’s about real-world assay conditions, and that's where our process plays out—minimizing batch variance, keeping moisture content low, and hitting high purity thresholds by scraping off even faint colored impurities at the final step.
Any manufacturer can talk about purity, but we see the real test during peptide synthesis and product handling. H-Ala-Pna HCl reacts to careless moisture control and impure solvents, leading to false readings or enzyme inhibition in test runs. There's a reason we've committed to using only fresh, traceable starting materials. We avoid lengthy storage, always running new batches through TLC, HPLC, and spectral analysis before release. Once a scientist finds a substrate contaminated with hydrolysis byproduct or gets peak broadening on a column, months of project time go off-track. Our own R&D has taught us that the difference between reproducible reactions and headaches often comes down to keeping a tight grip on each purification step, not just ticking boxes on a standard protocol.
Customers usually ask about the appearance, melting point, water content, and typical batch sizes. We keep H-Ala-Pna HCl as a pale yellow crystalline powder, with a melting point generally falling between 183°C and 187°C after two full recrystallizations. Moisture content by Karl Fischer in our recent runs stays under 0.5%. Unlike some suppliers who rely on large, consolidated lots, we prefer handling multiple small batches. This lets us tighten quality checks and pull analytical samples from every segment of the product. Our experience tells us this is the most direct way to spot anomalies and head off trouble at the source.
On the usage front, enzymologists use H-Ala-Pna HCl as a chromogenic substrate for measuring aminopeptidase activity. We've seen its popularity in both manual cuvette assays and fully automated plate readers. The free para-nitroaniline forms a distinctive yellow color under neutral or slightly alkaline pH. These reactions need no fancy readout; a trusty spectrophotometer at A405 tells the whole story. As manufacturing partners, we get frequent firsthand feedback: lack of byproducts leads to sharper peaks, clearer activity curves, and confidence in quantitative comparisons.
In our labs and those of our customers, it's clear that handling simplicity matters. H-Ala-Pna HCl dissolves easily in distilled water, giving stable stocks at centrifuge-compatible concentrations. We package it in air-tight, light-protective bottles, always shipped with double-layer moisture-absorbing liners. In our trials and the feedback we hear, degradation by hydrolysis poses the chief threat. That's why we advocate for immediate aliquoting and refrigeration whenever possible. Our own lot stability studies show negligible loss of activity for at least nine months at 2–8°C, but once vials are unsealed, careful resealing counts the most.
Some researchers also try H-Ala-Pna HCl in different enzyme specificity screens and high-throughput formats. Each application asks for a product that will not interact poorly with common buffers like phosphate or Tris. Our batches perform with zero interference and no extra background coloration, as shown by side-by-side comparisons against commercial alternatives.
We’ve heard stories of researchers fighting against background absorbance or puzzling over strange behavior in negative controls. These headaches usually trace back to batch contamination: residual solvents, incomplete coupling, or dimers in the substrate. We operate on the principle that every removed contaminant brings the product closer to being invisible in a control setup. High-purity H-Ala-Pna HCl means you get one absorption peak—free from drift, haze, or secondary signals. Our lot certification doesn’t just look good on paper. We hand over full HPLC, NMR, and IR trace packets with every order, each trace matched to an internal reference from our own master library.
Routine pre-ship analyses check for heavy metals, especially since modern peptide chemistry can't tolerate surprise reactions at trace levels. Arsenic, lead, and mercury get screened out far below international pharmacopeia limits. We believe there’s no such thing as “acceptable” contamination—either a batch is clean or it isn’t.
Mistakes cost a lot more at scale. Our own missteps early on—like letting coupling steps run without vigilant pH checks, or working with aging starting materials—taught us hard lessons. Precipitation time, pH swings, and solvent washing all play a part in shaping the final purity. If something as simple as the crystallization temperature gets neglected, you end up with sticky solids or mother liquor contamination that won’t wash away. Reprocessing cuts into production time and pushes up cost, a problem for everyone down the chain.
Tracking back every minor impurity, we’ve modified routes and scrapped entire precursor lots if they show deviation. Years of documenting failures means we now GPS-tag every drum, bottle, and filtered batch, so tracing trouble is never a guessing game. After all, reproducibility drives reputation in this field.
A common issue in the market comes from off-color or photo-reacted batches. Some makers try to cut corners by rushing the oxidative cleavage step, which saves time but leaves behind colored byproducts that create background noise later. In our shop, workers record the exact exposure times to light and run each batch under controlled conditions, verifying absorbance on the spectrophotometer before grinding down the final product.
Unpleasant surprises pop up when operators skimp on protection from humidity and UV. That’s why we double-wrap all finished lots and recommend minimal light exposure even during weighing and sample prep. For anyone who’s been burned by photo-sensitive products wrecking a high-dollar assay plate, the logic speaks for itself.
Manufacturing isn’t just about keeping a formula running. The best feedback comes from our clients’ working labs, not just internal QA forms. We’ve had researchers call out early on for tighter batch certifications or ultra-low endotoxin labels, especially those running medical diagnostics or preclinical screening. So, our protocols shifted—adding second-pass HPLC runs for selected orders and ramping up our pyrogen testing. Each new user request becomes a checkpoint for refining our process, whether it means reducing solvent residues or supplying alternate vial sizes for different throughput levels.
Occasionally, a specific customer application triggers fresh research on our end. One protein screening group requested larger crystal forms for low-dusting pipetting; another, focused on forensic toxicology, needed non-reactive packaging for volatile sampling. These edge cases often reveal flaws in standard practices and drive micro-adjustments across the whole production line.
Shipping H-Ala-Pna HCl across seasons and continents puts another layer of challenge on us as the manufacturer. Our team listens closely to logistics partners. Summer heat, winter damp, and airport tarmac delays—every stage adds chances for product shift or spoilage. That’s why every outgoing lot comes bagged in thermal-wrap pouches and packed with fresh desiccant, not just a slip of indicator paper. Boxes get tested for moisture gain on long-haul flights and stacked for vibration testing during loading trials. If temperature-sensitive dyes in the cargo liner trigger, we swap out the whole shipment, not just the carton.
Feedback from export customers has helped us trust no outside support more than our own. Each international shipment gets tracked, with direct phone checks once deliveries land. Any signs of clumping or discoloration trigger an immediate replacement. Even when the product itself isn’t at fault, we see responsibility in making the process fail-safe.
Any enzyme substrate has its own quirks. H-Ala-Pna HCl brings distinct benefits and limitations compared to alternatives like H-Leu-Pna HCl or H-Gly-Pna HCl. Its N-terminal alanine ensures selective interaction with aminopeptidases that cleave X-Ala bonds, offering more targeted results for researchers screening for alanine-preferring enzymes. Our long-term clients often point out that substrates with bulkier N-end groups slow down reaction rates or obscure minor activity profiles, leading to misleading kinetic curves.
In the context of para-nitroanilide substrates overall, we see the best batch-to-batch reproducibility with H-Ala-Pna HCl. H-Leu-Pna or H-Phe-Pna can display minor solubility issues at higher concentrations, precipitating out or forming cloudy solutions that complicate assay setup. Users who have switched from longer or more hydrophobic peptide substrates notice much faster reaction clarity with H-Ala-Pna HCl, along with a lower threshold for visible yellow pigment development.
There’s also a cost argument. H-Ala-Pna HCl, being a single amino acid derivative, doesn’t carry the synthetic or purification burden of more elaborate oligopeptide substrates. This brings affordability for high-throughput screens and educational teaching labs. Some multi-residue pNA substrates pile on complexity that isn’t always needed for first-pass activity screens, adding both to price and troubleshooting headaches. In our production, minimalistic structure pays off: shorter chains mean fewer side reactions, easier purification, and faster fulfillment time.
Every process in the manufacture of peptide substrates has downstream consequences. We have revisited our solvent purification, crystallization, and waste neutralization steps with the environment in mind. Instead of relying on single-use glassware and disposable solvents, our lab techs now manage closed-loop recycling for wash stages and filter press condensates. Instead of sending spent solvents for incineration, we scrub, distill, and reuse for non-critical cleaning, minimizing hazardous discharge.
Staff training makes the biggest dent. Instead of the classic “batch ends, drain the vessel” mindset, our crew tracks each production stage digitally. If a process can be tuned to cut waste, or if a surprising byproduct can be isolated for in-house research, it gets flagged. This approach reduced our non-recoverable chemical output by about a third over the past two years. We see green chemistry not as a press release, but as a paycheck—less waste, safer workspaces, and cleaner water for the next production run.
Being a chemical manufacturer today involves blending established methodology with what’s next. Alongside our classic crystallization rigs and chromatography, we’ve phased in bench-top mass spectrometers and automated microplate readers. Faster feedback loops catch drift early and sharpen our process setup for each run. Our next investment aims at robotic weighing for filling and capping—reducing human skew while protecting product from incidental contamination.
Our hiring process prioritizes hands-on troubleshooting skills over paper credentials. Fresh grads bring digital know-how, but it’s the batch record and filter wrench that separate the reliable technician from the nice resume. Pairing young hires with production veterans shortens the learning curve and keeps attention where it matters: the chemistry itself.
H-Ala-Pna HCl is one small link in a chain of experiments that drive discoveries in biochemistry, diagnostics, drug discovery, and education. We see our impact ripple outward—not just in tested assays or clean data, but in every hour saved for a researcher who doesn’t have to troubleshoot unexpected batch variability.
Labs large and small place their reputation on the smallest batch, the least-visible peak. As producers, we respect that trust and focus every day on supplying a product that stands up to scrutiny, speeds up workflows, and leaves zero room for batch-to-batch surprises. We learn as much from customer results as from our own notebooks—each comment, complaint, or victory adds to our own best practices, guiding continual improvements through open dialogue and honest feedback.
The science of peptide substrates is only as strong as the weakest synthesis batch. H-Ala-Pna HCl benefits from purposeful production: selecting the right sequence, refining every purification, listening to lab feedback rather than relying on theoretical best practices. We keep this process close, hands-on, and ready to shift with new knowledge. The result isn’t just a fine powder in a bottle, but a dependable, widely trusted research material proven every week by the labs who order from us again and again.