HS Code |
490565 |
| Product Name | Glycylglycine Hydrochloride |
| Chemical Formula | C4H9ClN2O3 |
| Cas Number | 695-20-7 |
| Molecular Weight | 168.58 g/mol |
| Appearance | White crystalline powder |
| Solubility In Water | Soluble |
| Melting Point | 220-225°C (dec.) |
| Storage Temperature | 2-8°C |
| Ph 1 Solution | 3.5-4.5 |
| Ec Number | 211-794-2 |
As an accredited Glycylglycine Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Glycylglycine Hydrochloride, 100g, supplied in a tightly sealed amber glass bottle with a tamper-evident cap and clear labeling. |
| Shipping | Glycylglycine Hydrochloride is shipped in tightly sealed containers to protect against moisture and contamination. It should be transported at ambient temperature, away from direct sunlight and incompatible substances. Packaging complies with chemical safety regulations, ensuring the product’s integrity during transit. Handle with care according to standard chemical shipping guidelines. |
| Storage | Glycylglycine Hydrochloride should be stored in a tightly closed container, in a cool, dry, and well-ventilated area. Protect it from moisture, direct sunlight, and sources of heat or ignition. Store at room temperature, typically between 15–25°C (59–77°F). Keep away from incompatible substances such as strong oxidizers. Ensure proper labeling and access only to trained personnel. |
Applications of Glycylglycine Hydrochloride in Industrial ManufacturingAs an original manufacturer specializing in the production of Glycylglycine Hydrochloride, we supply this high-purity raw material to established sectors where its buffering properties and chemical stability support critical downstream processes. Explore the precise industrial uses adopted by leading producers in life sciences, bioprocessing, and specialty formulations. Each application reflects direct integration into certified production environments, with relevant standards, recommended formulation ratios, operation stages, and typical finished product types. 1. Bioscience Laboratory Buffer ProductionMajor biochemical reagent and buffer manufacturers rely on Glycylglycine Hydrochloride in the formulation of zwitterionic buffer systems used for pH control in protein and enzyme experiments. Due to its well-characterized buffering capacity near neutral pH, the material plays a role in both routine and advanced laboratory assays for life sciences. Its consistent performance under stringent analytical conditions supports accurate reproducibility in critical research applications where certification and traceability are mandatory. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Cell Culture Media ManufacturingProducers of highly specialized cell culture media include Glycylglycine Hydrochloride as a non-toxic pH stabilizer for mammalian and microbial cultivation systems, particularly for sensitive bioproduction applications. It ensures consistent biochemical environments by buffering changes throughout cell growth cycles, directly contributing to the control of cellular metabolism. Use centers on processes where trace contaminants and pH shifts critically impact yield and reproducibility of biologics and advanced cell therapies. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Diagnostic Reagent and In Vitro Diagnostic (IVD) Kit ManufacturingIVD manufacturers utilize Glycylglycine Hydrochloride to maintain the stability and activity of enzymes, antibodies, and detection molecules in diagnostic tests. Its absence of interfering ions and well-controlled pH buffering make it suitable for enzyme-linked immunosorbent assays (ELISA), clinical chemistry kits, and point-of-care detection systems. Ensuring reproducible test accuracy and batch-to-batch uniformity relies on the compliant sourcing and homogenous incorporation of this raw material. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Protein Purification and Bioprocessing SolutionsDownstream bioprocessing facilities specializing in protein therapeutics and research reagents select Glycylglycine Hydrochloride as a solubilization and elution buffer component in chromatographic separation and purification lines. Its controlled ionic strength and compatibility with stabilizing additives aid in optimizing target yield and purity during affinity, size-exclusion, and ion-exchange processing. This application demands adherence to multi-stage traceability, with detailed batch segregation and analytical documentation. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Electrophoresis and Analytical Gel PreparationChemical suppliers for molecular biology and proteomics workflows deploy Glycylglycine Hydrochloride as a stabilizing buffer in polyacrylamide and agarose gel systems for electrophoresis. Its presence ensures accurate pH maintenance and minimizes background interference during protein or nucleic acid separation, especially in high-sensitivity or gradient gel systems. The formulation must adhere to strict documentation and trace chemical purity to prevent spurious results in gel-based bio-analytical processes. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive Glycylglycine Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Glycylglycine Hydrochloride has played a quiet but vital role in our production lines for years. As a direct manufacturer, we get a close look at how subtle differences in purity or consistency change your lab results. Our team pays special attention to sourcing raw materials, managing synthesis conditions, and carrying out purification to lock in quality with every batch. Glycylglycine Hydrochloride, with the chemical formula C4H9ClN2O3, stands out as a buffer and building block in biochemistry and molecular biology labs the world over.
Model GG-HCL appears as a white crystalline powder, with a typical assay above 99%. Moisture is controlled below 1%. We target low heavy metal content, with total impurities commonly kept under 50 ppm. Particle size matters during dissolution and measurement, so our milling achieves a consistent fine texture, free-flowing and easy to dissolve in aqueous media. Customers mention our product dissolves within a minute without stubborn clumps. Each lot receives batch-level documentation on identity and purity, facilitated by our in-house HPLC and titration analytics.
Most customers approach us to solve a buffer challenge. Glycylglycine Hydrochloride handles pH ranges just outside the sweet spot of other popular buffer systems, making it useful for enzyme studies, protein purification, and molecular diagnostics. Biochemists rely on it for its stable buffering between pH 2.5 and 3.0, as it holds ion strength predictably over time, even when working in open bench conditions. Students and postdocs tend to appreciate how it avoids forming insoluble complexes with common metal ions.
Labs using Glycylglycine Hydrochloride often compare it with its parent compound, Glycylglycine (the neutral form). Adding hydrochloride widens the product’s solubility and fine-tunes its buffering properties for acid-side applications. In diagnostics, we see this compound stand up to repeated heating and cooling cycles, keeping the solution clear and stable even after several freeze-thaw routines—important for folks running PCR or cold-chain dependent methods.
Our chemists take pride in keeping rare contamination events at bay. We mix starting amino acids under automated, audited conditions. We monitor pH and reaction temperature in real time. Each batch undergoes sequential filtration, followed by a final recrystallization step, to keep out sodium, potassium, and transition ions—the contaminants most likely to interfere with sensitive biological work. Our QC staff pulls dozens of random samples during packaging to confirm product meets or surpasses published benchmarks for color, odor, solubility, and residual solvents.
High-purity reagents leave no room for guesswork. Lower-grade Glycylglycine Hydrochloride shows up in the lab as cloudy stock solutions, unexplained enzyme inhibition, and unpredictable pH drift. We have seen firsthand how rigorous purification helps labs avoid failed runs—saving time, rare enzyme stocks, and funding. Our product is trusted by teams calibrating new diagnostic assays; they lean on its repeatable buffering, which supports consistent signal detection and sharp protein bands in electrophoresis. Researchers mention far fewer repeat runs when using fresh packs of our material compared to generic imports.
Many scientists ask us how Glycylglycine Hydrochloride stacks up against HEPES, Tris, or phosphate buffers. Each has a unique pH range and interacts differently with proteins. Where Tris can disrupt certain enzymatic activities and HEPES carries risks of metal contamination, our product stands out with minimal interaction in metalloprotease or metalloenzyme work. Labs working with sensitive proteins, especially those with post-translational modifications, appreciate the inertness of the Glycylglycine backbone. The hydrochloride form helps maintain solubility in complex mixtures and avoids precipitation, a common problem with phosphate-based buffers in high-calcium or magnesium solutions.
Volume requirements shift dramatically between academia, biotech firms, and industrial customers. Small benchtop protein studies may need only a hundred grams a year. Contract research outfits or manufacturing sites buy Glycylglycine Hydrochloride in 25 kg drums, seeking the same quality they see in analytical vials. For larger-scale applications, we fill orders by the ton and work with partners to meet unique filtration, particle size, or packaging needs. Some vaccine developers need sterile, pre-weighed aliquots, while food and beverage producers favor traditional industrial packaging.
Our facility supports flexible scheduling, allowing custom lots to be synthesized according to customer project timelines. This approach delivers just-in-time stock solutions for time-sensitive clinical trials or urgent research pivots. Honesty about lead times and batch turnover keeps our planning efficient, with no shortchanging on specifications or compliance.
Lab managers demand traceability on every lot. Each container carries a batch number painted right onto the drum or bottle—never just on a sticker—linking it directly to a full documentation trail. Electronic copies provide chemical signatures, GC-MS profiles, and physical inspection logs. We maintain archived retain samples for every batch so that, if any customer question or audit arises, we can compare materials side-by-side and provide rapid answers.
Our quality control staff cross-train across synthesis, packaging, and release testing. They know what customer complaints often sound like and what small issues snowball into major problems. Our lab personnel review recent returns quarterly, searching out even the smallest shifts in purity, pH stability, or solubility to spot process drift before it affects a customer’s project. Long-term stability studies back up shelf life claims, offering confidence in storage even under challenging climate conditions.
Glycylglycine Hydrochloride works well in more than molecular biology labs. Analytical labs use it as a reference material in titrations and calibrations, since its defined composition gives predictable results year after year. Some food laboratories include it during amino acid analysis, relying on its compatibility with sensitive LC-MS and HPLC methods. In pharma manufacturing, process engineers have incorporated Glycylglycine Hydrochloride during purification stages, taking advantage of its chemical stability and low reactivity.
We field regular questions about the best practices for handling and storing Glycylglycine Hydrochloride. The product ships in tightly sealed containers to keep out air and moisture, with each pail lined and double-bagged. During hot months or in humid climates, we recommend storage in dry cabinets above the lab bench or in temperature-controlled areas. Detailed SDS documents accompany each shipment, describing the straightforward handling steps favored by our own in-house safety teams. Standard PPE and basic chemical hygiene suffice during routine use. Our staff reinforces the habit of weighing the reagent quickly, closing the lid, and storing it away—simple steps that guard against clumping and loss of potency.
Our plant receives feedback and optimization requests from academic users, biotech teams, and pharmaceutical developers around the world. Open channels for feedback give us a direct sense of shifting research needs, and we regularly run pilot test lots for new applications. In recent years, several groups running high-throughput screening asked for enhanced solubility—our lab staff worked overtime tweaking crystallization and drying parameters, eventually shipping a custom-fitted product within weeks. Others struggled with contamination picking up during transport in the summer, prompting us to add improved inner bagging and vacuum-sealing options that now come standard for export orders.
Countries regulate chemicals in different ways, and developers working in diagnostics or finished pharma goods require extra documentation. Our technical staff maintains up-to-date details on regulatory requirements from the United States to Japan and the European Union. Batches intended for regulated markets ship with certificates of analysis, full traceability records, and clear statements on residual solvents, allergens, and bio-origin. We keep digital certifications on file in anticipation of random audits or supplier qualification visits, reducing the stress for customers managing complex compliance requirements.
Maintaining compliance calls for ongoing review and improvement, so our technical committee meets every quarter to audit internal procedures against external requirements. We join international industry quality groups, adapting our documentation and plant hygiene to fit best-practice standards seen at leading suppliers globally.
Some experimental designs reveal subtle shortcomings in general-purpose reagents. Labs running time-sensitive enzyme assays have discovered that small contaminant ions can either accelerate or suppress reactions in unexpected ways. Glycylglycine Hydrochloride, when synthesized to ultra-high-purity, stays out of the way, avoiding confounding results. Teams working on thermostable polymerases during PCR cycles credit our product with reducing baseline drift and shoring up repeatability when results determine publication success or failure.
Many clinical trial groups ask for documentation supporting viral and endotoxin controls. Our reagent batches undergo frequent testing and are packaged to avoid post-production contamination. This safeguards their pipelines, especially when protocols specify strict traceability for every secondary reagent. The integrity of research outcomes depends not just on individuals at the bench, but on every hand that touches that batch—ours included.
We operate a pilot plant at our main site, where senior scientists work together with process engineers to trial new reaction routes, purification media, and enhanced monitoring tools. Results feed straight into our production lines. Investments in real-time monitoring equipment—inline pH probes, filter particle counters, automated temperature controls—give us precise feedback that helps tighten up batch consistency. We record and analyze deviations, working them into future batch protocols.
We sponsor projects at local universities, including method development and advanced analytics. Insights from that work lead to better detection of trace byproducts, giving our customers more confidence in their results. It helps us identify real-world testing conditions not found in the academic literature. Recent collaborations revealed unique metal complexation issues under extreme pH, spurring tweaks to our ion-exchange steps to further reduce contaminant profiles.
Direct lines with procurement teams and lab managers have sharpened our sense for the issues that matter most. Over the years, we’ve witnessed the way a clear flow of product and documentation speeds up research or slows it down. Labs in remote locations spoke up about transit time gaps, so we built up regional warehouses and trained local technical representatives to offer real-time support, address emergent issues, or coordinate quick swaps in rare cases where a shipment falls short.
We regard every repeat order as a sign that our formula and process keep up with the needs of busy, solution-focused research units. On rare occasions, customers have flagged packaging faults or off-color batches. We treat these lessons as valuable, updating both internal training and supplier engagement standards. No batch leaves the plant unless lab-tested against a reference standard and a random sample opened and redissolved by QC chemists.
Manufacturing efficiency sits alongside environmental goals. Our facility continually invests in water-recycling systems, closed-loop steam heating, and chemical recovery programs. We recover byproducts and reprofile them into new chemical streams wherever possible. Glycylglycine Hydrochloride production, by design, produces few hazardous byproducts, and staff maintain strict control over effluent treatment.
We transitioned packaging to largely recyclable, lightweight materials, reducing landfill impact and simplifying handling for customers. Sourcing favors suppliers that demonstrate equally strong environmental practices—sourcing amino acids from established, traceable networks. Waste audits every year inform our next set of environmental performance goals and keep us answerable to direct customer queries on green manufacturing metrics.
Fast-changing markets and research priorities push our supply chain toward more agile responses. We rolled out continuous online tracking tools, letting customers follow shipments from plant to door. Unexpected delays or customs bottlenecks receive personal calls from our logistics team. Our lab dispatch offers rapid lot confirmation, replacement shipments, and technical troubleshooting based on customer call logs and feedback notes.
We measure our performance not just by volume shipped, but by how smoothly research teams move to publication and new product releases. Every new batch presents lessons; every unique customer request leaves a mark on our next round of process improvements. We stay focused on providing a steady, predictable supply of high-purity Glycylglycine Hydrochloride so customers concentrate on what matters most—the next scientific breakthrough or reliable production run.