Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Fura 2-AM

    • Product Name Fura 2-AM
    • Alias Fura-2 acetoxymethyl ester
    • Einecs 104068-90-0
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    243347

    Product Name Fura 2-AM
    Chemical Formula C35H36N4O17
    Form Lyophilized powder
    Solubility DMSO
    Cell Permeability Cell-permeant
    Storage Temperature -20°C
    Usage Calcium indicator
    Purity Typically >95% (HPLC)
    Cas Number 108968-38-1
    Color Off-white to pale yellow
    Sensitivity High for Ca2+
    Application Fluorescence microscopy

    As an accredited Fura 2-AM factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Fura 2-AM is supplied in a small amber glass vial, containing 1 mg of lyophilized powder, with tamper-evident seal.
    Shipping Fura 2-AM is typically shipped on dry ice to maintain its stability, as it is temperature-sensitive. The chemical is provided in a sealed, light-protective container to prevent degradation. Shipping is done in compliance with regulations for hazardous materials, and includes necessary documentation for safe handling and delivery.
    Storage Fura 2-AM should be stored desiccated at –20°C, protected from light and moisture. It is highly sensitive to hydrolysis and light, so always keep it tightly sealed in an amber vial. For best results, store the powder or aliquoted solutions in small amounts to avoid repeated freeze-thaw cycles. Prepare and use solutions fresh to maintain optimal activity.
    Application of Fura 2-AM

    Applications of Fura 2-AM in Industrial Manufacturing

    Fura 2-AM serves as a specialized fluorescent calcium indicator, widely adopted across sectors requiring high-sensitivity intracellular calcium detection. As the original manufacturer, we supply this material in accordance with exacting industrial production needs, supporting downstream innovation for life sciences, pharmaceutical development, medical diagnostics, preclinical screening, and neuroscientific instrumentation assembly.

    1. Pharmaceutical Cell-Based Assay Development

    Drug discovery laboratories incorporate this chemical as a ratiometric calcium flux probe in high-throughput screening (HTS) platforms where reliable quantification of cellular response is essential. Researchers prefer this dye for multiplexed GPCR and ion channel modulation assays. By loading whole-cell monolayers or suspension cells with the indicator in DMSO-based buffers, specialists achieve rapid, reproducible signal output, enabling robust data for target validation and compound library profiling.

    Industry compliance standards

    • ICH Q2(R1): Validation of Analytical Procedures
    • 21 CFR Part 11 (for electronic records where applicable)
    • ISO 13485:2016 for diagnostic test development
    • USP <1043> Ancillary Materials for Cell, Gene, and Tissue-Engineered Products

    Typical usage ratio

    • Final loading concentration: 2–10 μM in cell assay wells
    • Depends on cell type density and membrane permeability; adjusted based on assay window and background

    Downstream process integration

    • Dissolve in DMSO or Pluronic F-127 before addition to assay buffers
    • Introduce into automated or manual plate handling prior to compound incubation
    • Compatible with 96-, 384-, and 1536-well HTS formats
    • Signal readout via fluorescence plate reader or confocal imaging systems

    Final product types

    • Calcium flux screening assay kits
    • Cell signaling characterization panels
    • Preclinical safety assessment HTS services
    • GPCR functional high-content cell models

    2. Life Science Research Reagents Manufacturing

    Major reagent houses and contract manufacturers use this fluorescent dye as a raw intermediate for producing ready-to-use live cell imaging kits. After formulation, the calcium indicator is included in bulk packaging lines or dispensed into unit-dose vials intended for laboratory and CRO customers. Formulation teams optimize for shelf stability, lyophilization compatibility, and extended light resistance, ensuring high performance in downstream research workflows.

    Industry compliance standards

    • ISO 9001:2015 for reagent manufacturing
    • REACH Regulation (EC) No 1907/2006 for raw material import to EU
    • GMP for Investigational Research Use Only (RUO) where designated
    • US OSHA Hazard Communication Standard (29 CFR 1910.1200)

    Typical usage ratio

    • Bulk solution: typically 1–5 mg per finished kit, standardized by lot
    • Mastermix preparations: 1–10 μM in working reagent vials
    • Ratios adjusted to meet customer specification sheets and BRD requirements

    Downstream process integration

    • Dissolve in anhydrous organic solvent or minimal aqueous buffer under inert atmosphere
    • Metered dispensing to mono-dose or multi-dose sterile vials
    • Co-packaged with calibrant buffers and cell loading reagents
    • Final QC by fluorescence spectrometry and HPLC identity validation

    Final product types

    • Cell calcium imaging reagent boxes
    • Live cell fluorescence microscopy kits
    • Custom indicator blends for calcium kinetic studies
    • Research-use consumables for microscopy and flow cytometry

    3. In Vitro Diagnostic (IVD) Kit Production

    Diagnostic manufacturers deploy this indicator as a critical functional component in automated analyzers designed for ex vivo calcium flux quantitation in clinical specimens or platelet function assays. Manufacturers require traceability for all chemical components and demand controlled impurity profiles. The dye is formulated under stringent batch release protocols and can be pre-mixed with sample diluents or lyophilized into analyzer cartridge wells, supporting high-throughput patient sample processing in hospital and laboratory settings.

    Industry compliance standards

    • IVDR (EU) 2017/746 for In Vitro Diagnostics
    • ISO 13485:2016 Medical Device QMS
    • FDA 21 CFR 820 Quality System Regulation
    • CLSI EP05-A3 for Evaluation of Precision

    Typical usage ratio

    • Ready-to-use cartridge: 1–3 μM per sample chamber
    • Stored in lyophilized or liquid stable form; precise ratio defined by cartridge microfluidics

    Downstream process integration

    • Pre-loading into microfluidic analyzer wells by automated filling
    • Integration with internal calibrants and quality controls
    • Sealed packaging with barcode and batch tracking
    • Post-manufacture validation through automated test runs with reference plasma or cell samples

    Final product types

    • Platelet function assay cartridges
    • Whole-blood calcium diagnostic cassettes
    • Automated bench-top analyzer reagents
    • IVD test strips for specialty diagnostic markets

    4. Neuroscience Optical Biosensor Fabrication

    Developers of optical biosensors and imaging systems use this calcium indicator as a core active sensing element in ratiometric fluorescent probes for neural activity. R&D teams integrate the compound into high-sensitivity sensor coatings or microinjection systems for use in brain slice preparations, cultured neurons, or in vivo preclinical animal research. The material must demonstrate low cytotoxicity, photostability, and predictable dissociation constants to capture robust signal transients during live neural event measurement.

    Industry compliance standards

    • Directive 2010/63/EU on Animal Use in Scientific Research (for in vivo applications)
    • GLP (Good Laboratory Practice) for preclinical protocols
    • Society for Neuroscience Ethical Guidelines
    • US NIH Guidelines for the Care and Use of Laboratory Animals

    Typical usage ratio

    • Neural tissue slices: 5–20 μM for acute slice incubation
    • In vivo microinjection: 10–50 μM, adjusted for tissue depth and experimental duration
    • Concentration fine-tuned for dye loading efficiency and background minimization

    Downstream process integration

    • Solubilized with Pluronic F-127 for tissue penetration
    • Loaded into microelectrode pipettes or microfluidic perfusion systems
    • Applied to acute slices or directly injected into brain regions under stereotaxic control
    • Fluorescence signals captured by high-speed confocal or multiphoton microscopes

    Final product types

    • Optical biosensor kits for neural activity
    • Pre-filled microinjection cartridges for neuroscience R&D
    • High-sensitivity imaging plates for research institutions
    • Advanced multi-photon neural imaging assemblies

    5. High-Content Screening Instrument Calibration

    Manufacturers of high-content imaging and screening platforms select this indicator for factory calibration of multi-wavelength excitation/emission systems. Engineering teams establish reference standards by embedding dye at specific concentrations onto calibration slides or within sealed microplates. This ensures consistent performance, instrument validation, and traceable fluorescence benchmarks for regulatory documentation and after-sales customer support worldwide.

    Industry compliance standards

    • ISO 8655 for laboratory instruments calibration
    • IEC 61010-2-081: Safety requirements for laboratory equipment
    • GMP calibration standards (where used in GMP-regulated QC environments)
    • NIST-traceable fluorescence calibrant certification

    Typical usage ratio

    • Microplate reference standards: 1–10 μM per well
    • Calibration slides: 2–20 μM matrixed by emission intensity requirements
    • Concentration adjusted for instrument sensitivity and photobleaching resistance needs

    Downstream process integration

    • Prepared as homogenous solutions or gels for spotted loading onto calibration substrate
    • Sealed under inert conditions to preserve fluorescence stability during warehousing and shipment
    • Integrated into calibration software protocols for automated performance check routines
    • Final validation documented with traceable calibration certificates

    Final product types

    • Factory-calibrated fluorescence microplates
    • Standardized reference slides for high-content imagers
    • Field-service calibration kits for distributed analyzers
    • Instrument validation packages for regulated laboratories
    Free Quote

    Competitive Fura 2-AM prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Fura 2-AM: A Reliable Calcium Indicator for Cell Imaging

    Direct Perspective from a Chemical Manufacturing Floor

    Every year brings fresh challenges in the laboratory. We've watched scientists push the boundaries of what’s possible in live cell imaging, and fluorescent calcium indicators pop up again and again in conversations. Fura 2-AM stands out, not because brands hype up the molecule, but because its behavior in hands-on, day-to-day research tasks earned real trust. We’ve put in years refining our batches, working to curb impurities and looking for consistency—critical steps when calcium signal data leaves little room for noise or artifacts. The AM ester form, favored for its permeability, reflects a practical solution to one of the oldest headaches in organismal biology.

    Why Consistency and Purity Become Non-Negotiable

    I still remember the frustration of seeing low yields or spotty cell loading with poorly handled esters. Any lab technician handling live cells wants their Fura 2-AM to dissolve smoothly, with no surprising residues, and to deliver clear separation once the ester gets cleaved inside the cytosol. We build every batch with this goal in mind. Each finished bottle comes off the line with its purity scrutinized by HPLC—no shortcuts.

    Raw calcium signals matter most when you compare conditions: stimulated versus resting, or wild type versus mutant. A spike is only as meaningful as the baseline you measured it from. If you’ve ever traced your problem with background noise back to sub-par product, you understand why lot-to-lot consistency gets so much attention in our QA meetings. Getting that consistency doesn’t happen by chance. Our team reviews every synthetic step, confirming every precursor before moving on. Incidents of hydrolysis, even at low levels, hurt Fura 2-AM’s signal. We insist on traceability at every stage.

    Technical Aspects that Directly Affect Research

    Researchers expect a defined λexc and λem—in this case, excitation at 340/380 nm and emission near 510 nm. For almost four decades, these wavelengths have set the standard for ratiometric calcium imaging. We don’t smooth over deviations; any batch with scrambled spectral properties goes straight to remediation. You can trace every powder back to its synthetic origin, right through the evaporation, crystallization, and freeze-drying stages. Each final container gets a certificate, but these papers only echo our hands-on checks.

    Solubility matters for Fura 2-AM, not only for convenience but for the success of loading protocols. Whether you introduce the dye with Pluronic F-127, use a mild detergent, or prepare it in DMSO before adding to cells, clumping simply wastes time and precious cells. We've adapted our formulation approach based on real-world feedback—if cell cultures struggle, batch records guide possible troubleshooting before researchers lose rare samples. Some formulations across the industry run into premature hydrolysis or unpredictable cellular uptake. Instead of masking these issues, we work to either eliminate them or flag them on every QC report.

    Comparative View: Fura 2-AM’s Place in Calcium Imaging

    Many labs still use Fura 2-AM despite a long list of other probes. Competing indicators, such as Fluo-4 or Indo-1, certainly have their strengths—no one in the field can deny that single-wavelength indicators simplify workflows or that red-shifted dyes can avoid overlaps with common cellular autofluorescence. From what we observe in orders and researcher correspondence, Fura 2-AM stays popular among those needing ratiometric quantification and tolerating moderate UV excitation. The value here is the dye’s ability to balance calcium buffering with clear emission shifts. A single-wavelength probe might look brighter under the microscope, but Fura 2-AM’s real utility comes in its clean comparison between loaded and unloaded states, even in difficult sample types.

    Others might market “no-wash” versions or modified esters. But for honest quantification in tricky live cells—especially where you have big swings in baseline calcium—Fura 2-AM’s noise-canceling ratio lets you skip guesswork. Some new probes push for increased sensitivity or compatibility with lower-cost optics. Researchers under tight grant budgets may weigh these alternatives, but when quantification and reproducibility count, Fura 2-AM consistently claims the top spot on experimental protocols.

    Usage in Practice: From Bench to Imaging Rig

    If you picture a typical plate-based Ca2+ imaging study, the lab tech starts with a stock in DMSO, often no bigger than 1 mM. Handling the powder means quick work; Fura 2-AM hydrolyzes with moisture, and even brief air contact makes a difference. The powder’s almost chalky appearance looks unremarkable, but how it disperses in solution can spell success or frustration later. We package every vial to reduce static and limit water ingress. Once in solution, users quickly dilute into their culture medium, sometimes with help from Pluronic agents. The cells soak for 30-45 minutes, at temperatures never straying far from ambient. After a wash, what’s left inside the cell carries the calcium-binding message forward towards the microscope or plate reader.

    Proliferative and differentiated cells sometimes load with different efficiency; old, unhealthy cultures take up less dye and show flatter responses, a problem we try to mitigate with both formulation and technical advice. Most cytosolic release gets verified using standard excitation switches. If the signals look faint, batch records and typical troubleshooting questions rule out storage, light exposure, and mixing techniques.

    Whole tissue sheets and slice preparations run up against uneven dye penetration, but Fura 2-AM, with tolerant loading protocols, can handle slow incubations or triple-wash sequences. We watch how new labs adapt our reference protocols to unique cells and tissue types, then fine-tune our workflow recommendations accordingly.

    What Matters to Cells Matters to Us

    Any dye with AM ester functionality carries a risk of spontaneous hydrolysis, and trained chemists look for clues during every handling step. We calibrate our humidity controls to a fraction of a percent on the line where batches get dried and sealed. Even the tiniest rise in water content flags our intervention—often replacing raw materials and extending pre-release reviews. As a manufacturer, nothing replaces direct testing in both buffer and cell lines. We run parallel cell loading reactions across every batch, using wild-type human fibroblasts and cardiac myocytes to probe possible hidden impurities or unexpected aggregation. Sometimes, a rare contaminant escapes traditional specs but shows up in odd loading curves. Instead of quietly discarding those batches, we study the side products, adjusting purification routes or synthetic starting points for future runs.

    Fura 2-AM’s cargo—the Fura-2 core—binds free Ca2+ with an affinity most appropriate for physiological ranges. This tuning keeps readings within reach for diverse experiments, from neuronal studies to contractile cell sheets. As demand shifts from single-dish validation to high-throughput screening, we continuously refine our lyophilization and vialing steps to support both small research groups and large facilities with robotic pipetting routines. Analytical staff test for photostability, targeting the wear and tear encountered by repeated excitation cycles, especially on older fluorescent plate readers.

    Safety by Design, Not Just Documentation

    Handling Fura 2-AM rarely leads to dangerous exposures if researchers respect standard laboratory hygiene. We reinforce this at every labeling and packaging step, anticipating user environments from undergraduate teaching labs to pharmaceutical scale-up suites. Our product labels, vials, and inserts remain durable under freezer storage, and we monitor every transport run for temperature excursions—even slight warming can push hydrolysis rates in the wrong direction. As we manufacture, we maintain negative pressure areas and high-efficiency filtration not just for our own personnel but to ensure every microgram of finished Fura 2-AM reflects high safety and purity standards.

    Incidents of mishandling usually trace back to rushed aliquoting or keeping DMSO stocks out at room temperature for too long. We work with supply chain partners to shorten times from line to freezer, and our technical staff remain on hand for troubleshooting, not just order fulfillment. This commitment to support cuts down wasted batches, supports new users, and upholds our responsibility for the product well after it leaves the warehouse.

    Ongoing Dialogue with the Scientific Community

    Responsiveness makes a difference as fields evolve. The influx of optogenetics, cardiac pacing technologies, and advanced microscopy calls for tighter tolerances, not just in basic purity but in every aspect of dye handling and labeling. Manufacturing staff regularly review published literature, technical support logs, and direct researcher correspondence to identify where even minor improvements will compound in scientific benefit. If a research group in biophysics reports a trend toward photobleaching at higher excitation cycles, we dig into our fluorescence decay records and sometimes retool a drying step or packaging material. If a stem cell group points out anomalies in cytosol cleavage across different donors, we investigate links between raw material batch and final biological profile.

    Our ongoing training for production chemists mirrors these evolving expectations. We invest in HPLC, NMR, LC-MS analyses, and cross-checks using internal and external reference standards. It’s not enough to hit a technical reference value on a sheet—every batch gets checks in a real-world biological context before release.

    Addressing Real-World Challenges

    Missteps often begin with a simple oversight: storing vials in frost-prone freezers, opening containers on humid days, or reusing DMSO stock too long. We engage labs right at introduction, sharing step-by-step handling advice drawn from both internal trials and field experiences, all informed by our process critiques. Sometimes, research groups implement new automation equipment only to find Fura 2-AM offers less flexibility than modern dyes in no-wash protocols. We don’t dismiss such limitations; instead, we keep lines open, offer alternative handling tips, and re-assess batches exposed to emerging robotic handling routines.

    Environmental conditions in the end-user lab differ from those in our controlled production space. Temperature, humidity, and even atmospheric composition impact stability during quick bench work. Recognizing these discrepancies, we adapt our packaging, storage recommendations, and lyophilization cycles to better mimic the most demanding usage contexts. Batches that don’t meet tight parameter windows are held back for internal review or reformulation.

    Fura 2-AM’s cell permeability via AM-ester technology creates flexibility for studying both adherent and suspension cells, brain slices, and isolated tissue strips. Yet, even the best dye won’t solve poor technique or sample prep. We meet this reality by openly sharing variables most prone to trouble—water content, temperature, loading time, and light exposure—so groups can avoid repeating costly mistakes.

    Future Directions: Sustainable and Open Practices

    Any chemical producer faces a balance: scaling high-quality synthesis while limiting environmental impact and ensuring every increment of increased supply doesn’t invite shortcuts. Our teams constantly scout for green solvents, alternative waste capture pathways, and energy-efficient drying methods. As global scrutiny on chemical safety and process transparency grows, we share our efforts and invite external audits. Reducing hazards in esterification reactions or improving trace contamination removal benefits not just our staff, but downstream users, animals, and ecosystems.

    We collaborate with collaborative partners and researchers at peer institutions, comparing side-by-side performance and gathering feedback on aging, handling, and imaging outcomes. These benchmarks refine our protocols, guide improvement investments, and keep our team attuned to shifts in research trend or regulatory climate. A batch of Fura 2-AM produced ten years ago set a high standard; today, it drives us to exceed it, responding to current and future scientific demands.

    Conclusions Rooted in Direct Experience

    Manufacturing Fura 2-AM for use in high-value research holds us to a level of reliability and transparency few industries match. Our staff take personal pride in every batch released, motivated not just by standards or sales, but by the knowledge that real-world outcomes—deep inside living cells—rely on choices made at every step of synthesis, purification, and packaging. We see the dye at work in labs around the world, adding data points to experiments that unlock new scientific understanding, from cardiac health to neurodegeneration. Each feedback loop from the field helps shape our future production methods and inspires constant attention to detail. In this way, Fura 2-AM represents not simply a product, but a shared commitment between manufacturer and researcher to build authentic insight, one experiment at a time.