HS Code |
279846 |
| Chemical Name | Fluorescein Diacetate |
| Synonyms | FDA, Fluorescein diethyl ester |
| Molecular Formula | C24H16O7 |
| Molecular Weight | 416.38 g/mol |
| Appearance | Light yellow to yellow powder |
| Solubility | Soluble in DMSO, acetone, and alcohol |
| Purity | ≥ 98% |
| Storage Temperature | -20°C, protected from light |
| Cas Number | 596-09-8 |
| λmax Absorption | 494 nm |
| Melting Point | 174-177°C |
| Usage | Cell viability and esterase activity assays |
As an accredited Fluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Fluorescein Diacetate is packaged in a 1-gram amber glass vial with a screw cap, labeled for laboratory use only. |
| Shipping | Fluorescein Diacetate should be shipped in a tightly sealed container, protected from light and moisture. It is typically transported at ambient temperature, unless otherwise specified. The package must comply with applicable chemical safety regulations, including labeling as a laboratory reagent and precautions to prevent exposure or spillage during transit. |
| Storage | Fluorescein Diacetate should be stored in a tightly sealed container, protected from light and moisture. Keep it at -20°C in a dry, well-ventilated area, away from incompatible substances such as strong oxidizing agents. Avoid repeated freeze-thaw cycles by aliquoting it into smaller portions and storing them properly to maintain chemical stability and effectiveness. |
Applications of Fluorescein Diacetate in Industrial ManufacturingFluorescein Diacetate supports a variety of critical downstream manufacturing sectors through its unique suitability for viability assays, quality assessment, and contamination monitoring. Drawing from our longtime production experience, we highlight below the principal industrial applications utilized by our clients, detailing integration methods, compliance frameworks, formulation guidance, and resulting end products. 1. Microbial Viability Assessment in BioprocessingBiomanufacturers apply this material extensively for evaluating live cell and microbial activity during production scale-up and quality checks. Its hydrolysis by active esterases in living cells generates a fluorescent signal, central to rapid assays for bioreactor health, contamination risk, and process consistency. Our formulation guidance reflects industry technical demand for reliable quantification—minimizing downstream batch loss and ensuring regulatory acceptance of the final biological product. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Plant Cell Viability Testing in Plant Tissue Culture ProductionCommercial plant tissue culture labs and agri-biotech operators depend on this compound for high-throughput monitoring of cell cultures used in micropropagation, varietal improvement, and mass propagation systems. Its selective fluorescence allows rapid identification of viable explants and calli, ensuring reliable propagation cycles and uniformity in massive plantlet production environments operating under phytosanitary supervision. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Environmental Water Quality and Wastewater TestingEnvironmental laboratories utilize this material to assess total microbial activity in drinking water, surface samples, and industrial effluents. The rapid live/dead discrimination supports regulatory compliance monitoring and process troubleshooting for municipal utilities, beverage processors, and regulated industrial dischargers. The raw material’s ability to quantify active biomass ensures timely corrective actions in water treatment and compliance with effluent standards globally. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Animal Cell-Based Cytotoxicity and Tissue Engineering QCPharmaceutical and biotechnological manufacturers incorporate this raw material into assay kits and custom viability protocols supporting preclinical tissue models, stem cell production, and regenerative medicine matrices. Its enzymatic hydrolysis mechanism gives researchers and manufacturers reliable live/dead readouts in biocompatibility testing, scaffold development, and monitoring cell-based constructs destined for advanced medical technologies. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Quality Control of Probiotic Formulations in Food and FeedLarge-scale probiotic manufacturers and food additive formulators employ this compound for batch-to-batch viability testing of lactic acid bacteria and yeast used in dairy, fermented foods, and animal nutrition products. Consistent application ensures adequate live cell counts in finished formulations, supporting both process validation and required health claims for global market exports. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive Fluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Years of hands-on production have shown us just how important purity, consistency, and raw material traceability are for research and industrial users alike. Our operations with Fluorescein Diacetate, known to many as FDA, reflect a commitment to high standards and reliability that began in the earliest stages of our manufacturing process. We craft this compound with a focus on the details that matter most to those running cell viability assays, microbial tests, or enzymatic activity screens. The science rests on precise outcomes, and every step in our process pushes toward that goal.
In our experience, success always ties back to how well each batch matches the last. Researchers rely on us when their models, controls, and experimental designs call for fluorescence with predictable intensity and minimal background signal. When results vary from lot to lot, the headaches pile up. No lab wants to rerun controls or calibrate new standards each time a bottle arrives. That’s why every shipment undergoes a full spectrum of quality tests. Each specification aligns with common requirements in the literature, but we go further—tracking critical raw material lots, auditing reaction conditions, and confirming end-product photostability by exposure trials.
Fluorescein Diacetate stands out because of its application in living cell studies. Once exposed to intracellular esterases, it releases fluorescein, yielding a strong green signal. We formulate our FDA for sharp conversion and minimal side reaction. From our own benchwork and the feedback of hundreds of research customers, several key differences have emerged between our product and the market average.
Not all FDA powders or solutions handle humidity or light equally well. We learned early on that trace water, sometimes from careless packaging, speeds up hydrolysis and ruins shelf life. So, each vial from our line gets packed under dry air, in amber glass, and under tightly monitored humidity conditions—none of this leaves to chance. Customers tell us that other sources sometimes ship FDA in clear bottles or even plastic, leading to headaches about storage and unexpected degradation. In our practice, we only supply lot-specific documents and retain internal samples for reference, which allows any questions about a batch to be answered with a direct comparison from retained product.
Purity can look good on paper but hide trouble in use. We focus on both chemical purity and functional performance. That means regular batches go through HPLC, UV-Vis, and TLC checks, but we don’t stop there. After we hit 98% or greater purity on HPLC, in-house technicians run enzymatic conversion tests to confirm ester cleavage and fluorescence yield. This last step has highlighted problems with competitor products in the past—particularly those relying on only one analytic technique or skipping conversion checks entirely. Using only a certificate of analysis from a supplier leaves too many questions open. We insist on real-world validation in our own labs before a product stamp ever goes on the package.
Based on years of feedback from academic and industrial customers, the main points of interest converge on a handful of batch characteristics. Purity (by HPLC), water content (from Karl Fischer titration), and residual solvent levels guide much of our in-house monitoring. The actual numbers vary depending on the application, but we lock in a minimum purity threshold above 98%. Lower levels of acetic acid derivative or oxidized byproducts matter, especially for those working in sensitive flow cytometry or confocal imaging platforms. Impurities, even in fractions of a percent, can kick up background signal and confound low-fluorescence hits.
Solubility in commonly used solvents like acetone or DMSO is another frequent focus. Inferior FDA sometimes clumps, resists dissolution, or leaves behind colored particulates, which throw off quantitation and render automated pipetting unreliable. We routinely dissolve samples to confirm full solubility and optical clarity. From years of direct customer troubleshooting, we’ve seen how subtle changes in formulation affect user outcomes. No matter how much a specification sheet claims, microscopic insoluble debris throws off sensitive spectrophotometers or microplate readers and leads to real confusion in end results.
Batch-to-batch consistency is never an afterthought in our production. Each time we produce FDA, results get tracked against historical controls, and outliers get flagged for additional investigation. This habit followed us from early days when small anomalies in fluorescence response led to investigations that revealed slight shifts in reagent quality or reaction time. Some manufacturers skip this level of attention, but experience has convinced us most issues start from the ground up—with reagent selection, purification routes, and drying protocols.
Purity guarantees need enforcement. Our in-house analytics check for every common contaminant that we have seen flagged in academic journals or industry reports. Each run through our synthesis plant ends with a high-resolution HPLC trace, ensuring impurities down to 0.1% are caught. We also listen closely to user reports—if an unusual artifact shows up under their fluorescence microscope, we take that seriously and revisit both the manufacturing conditions and packaging decisions on our end.
Packaging isn’t a minor detail. In our local climate, humidity levels swing drastically over the year, and we’ve observed how even short exposures during packaging can kick off unwanted reactions. All bottles get filled and sealed in a dedicated moisture-controlled area. For many of our international customers working in hotter, damper climates, even minor slips in packaging can compromise months of work. We choose borosilicate amber vials to reduce light transmission, and wrap every vial with a tamper-evident seal after nitrogen flush. Waste here is low, stability is long, complaints from the field are rare.
Every researcher asks how to store and handle FDA for maximum reliability. The science and our experience say two factors matter: keep it dry, keep it cool, and protect it from light. Through consultation with laboratory staff, we realized how refrigerator lights or repeated thaw cycles bring up the background noise over time. We prep packaging and batch sizes so labs can use up a bottle quickly, minimizing air exposure.
Our staff uses the same batches to check internal QC, test protocols, and provide support, logging feedback straight from usage. Only when a typical working solution performs as expected under weak and strong light, within the same emission window, do we approve a lot for shipping.
Cell viability assays account for most customer questions. After years assisting researchers, we see how many use FDA in parallel with Propidium Iodide or Calcein-AM. Rapid, reliable hydrolysis to fluorescein simplifies workflow during high-throughput screens. For instance, in plant viability checks, users often combine FDA staining with mechanical stress or chemical challenge studies. Our product enables robust detection even in stressed or metabolically altered samples, saving time spent troubleshooting unclear signals.
Microbiologists rely on FDA, too. It’s a popular choice for live/dead cell discrimination in environmental and water quality monitoring. Feedback from field crews told us that rugged, transportable packaging reduced headache, cutting down on bottle breakage during transport to remote sites. In food safety labs, where contamination must be flagged quickly, labs raised concerns with sources who used bulkier bottles or left out lot-specific performance data. In response, we shifted to lighter-weight vials, improved label clarity, and added QR-coded batch data access upon request.
Enzyme researchers use fluorescein diacetate for real-time activity tracking. Many look for minimal background esterase activity from the product itself after extended storage. We focus on flushing our equipment and testing for low-level byproducts that can exaggerate base-line readings and confound kinetic studies.
Across the world, high school and undergraduate teaching labs trust our FDA for introductory fluorescence microscopy experiments. Since many students have never handled a light-sensitive chemical, clear usage notes and robust packaging help keep accidents and wasted reagents to a minimum.
Some suppliers cut corners, producing FDA that sounds correct on paper but disappoints in actual use because of quick-and-dirty drying, minimal impurity checks, or budget packaging. Labs encounter inconsistent signal strength, rapid yellowing of the powder, or bottle-to-bottle fluorescence differences. We recognize that even with strong documentation, users seek real technical support and transparent data. Our team has noticed that most problems in the field come down to overlooked basics: weak batch monitoring, poor humidity control, lack of real-world usage validation, or subpar packaging.
Our response stems from open data sharing and customer partnerships. Every lot includes traceable batch info. Researchers wanting more data get direct access to our QC records. In cases where anomalies pop up, we retrieve reserved reference samples, perform a direct check, and share results openly. This transparency practice reduces finger-pointing and helps identify true causes—sometimes tied to unique end-user storage conditions, sometimes to our own processing tweaks.
Some labs want FDA dissolved for quicker mixing or automation. We supply anhydrous solutions as a special order, made in freshly dried acetone or DMSO, and packed to customer-chosen volume. Any order shipped as a solution leaves our facility only after all particulate checks, purity confirmation, and full inert gas flush. Evidence has shown that “ready-to-use” solutions perform best for teams needing high-throughput, with zero time lost to grinding, weighing, and inconsistent manual dissolving.
The market occasionally brings in cheaper substitutes, often of unknown provenance or variable dye loading. Years of customer feedback underscore how unpredictable results cost far more than the small savings from questionable sources. Signal drop-off, high backgrounds, filter mismatches, or rapid loss of dye activity tell the story. We maintain close dialogues with technical users, which lets us catch shifts in demand or new assay protocols early and adapt batch controls to meet those changing needs.
Every month brings an unusual customer request—alternate solvents, reduced packaging, special labeling, or targeted impurity thresholds. In academic consortia, where collaborative work spans multiple countries or climates, bulk containers have to withstand transit with zero spoilage. We’ve invested in inert gas packing lines, moisture detectors, and trackable shipping that logs any temperatures or shocks en route. When a university or industrial group wants an FDA batch handled in their own containers, we clean and validate every vessel under cGMP-like scrutiny, avoiding cross-contamination or memory effects.
In routine production, we sometimes get challenges from early adopters looking to expand FDA use in novel fields, from algae biotechnology to biofilm research in marine labs. These conversations shape our own process control. As research pushes FDA into more nuanced or demanding roles, from single-cell analysis to new automated imaging platforms, we adapt purification and validation strategies. That’s how we catch emerging needs long before they shift the typical specification profiles.
Shipping logistics matter. International clients face changing regulations and customs controls. We learned to inspect each shipment route, tweaking documentation and adapting packaging density and labeling. In some countries, customs agents want detailed purity track records; in others, short shelf life rules make fast shipping essential. Our export team keeps on top of global regulatory updates to prevent confiscated or delayed shipments.
Quality and safety demand more than just words. Yearly, we audit our processes, checking bulk solvent sourcing, cleanroom standards, and packaging supply chains. Cost pressures never push us to trade principle for margin, as dozens of mistake-driven situations in the wider industry regularly prove. Labs burned by unstable FDA return seeking predictable supply; that trust took years to earn, and we keep it with stubborn attention to foundation details.
Inside the plant, technicians track environmental shifts and batch outcomes daily, checking for subtle signs that could signal later problems. In rush seasons, we train extra hands, making sure every batch leaves with the same care as the first one off the line. Our technical staff are trained in both the manufacturing and the laboratory use of FDA, tightening feedback cycles between production and application.
Mistakes have led to progress. Early hiccups—a missed humidity spike, a mislabeled storage vial—taught us to redesign checkpoints, introduce electronic batch logs, and overhaul staff training. Each corrective action got built into the production process, tracked in long-term trend reviews, and shared internally as case studies to prevent recurrence.
Ongoing education connects us to researchers’ evolving needs. By following new literature, technical talks, and direct customer reporting, our team spots trends that hint at upcoming shifts in use. This keeps our practices proactive, rather than reactive, giving us a leg up should new protocols or end-use regulations develop.
Real trust in a reagent doesn’t come only from technical data sheets, but from observed, repeatable results in live assays. We observe, modify, and share these reliability stories with partners and customers, encouraging honest feedback, even when it’s tough to hear. Every insight helps us deliver a better product and improve the process for the long haul.
We recognize Fluorescein Diacetate’s role in advancing biological understanding and raising experimental reliability. Our practices come from years of experience handling, packaging, and troubleshooting with this versatile reagent. Labs that count on consistent, high-fidelity cell viability or enzyme assays shape the focus of our production cycle, driving continual improvement.
From basic research to applied environmental outreach, the usability and reliability of FDA depend on real integrity at the source. We affirm that high-quality chemicals start from genuine dedication and a constant pursuit of betterment—not from marketplace gimmicks or fleeting trends. Our doors stay open to customer questions, suggestions, and transparent dialogue about quality, application, or logistics. Every feedback cycle strengthens what we deliver and forges enduring partnerships based on mutual growth and scientific advancement.