HS Code |
669960 |
| Chemical Name | Fluo 3-AM |
| Molecular Formula | C37H28F2N2O14 |
| Molecular Weight | 762.62 g/mol |
| Cas Number | 121714-22-5 |
| Excitation Maximum | 506 nm |
| Emission Maximum | 526 nm |
| Solubility | DMSO |
| Form | Lyophilized powder |
| Storage Temperature | -20°C |
| Usage | Calcium indicator |
| Cell Permeability | Cell-permeant |
| Color | Pale yellow to orange |
| Purity | Typically >95% (HPLC) |
| Synonyms | Fluo-3, acetoxymethyl ester |
| Light Sensitivity | Light-sensitive |
As an accredited (Fluo 3-AM) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Fluo 3-AM is packaged in a small amber glass vial containing 50 micrograms, with a secure screw cap and clear labeling. |
| Shipping | Fluo 3-AM is shipped in temperature-controlled packaging, typically on dry ice, to maintain its stability and prevent degradation. It is classified as a hazardous chemical, so shipping follows strict regulations, including proper labeling and documentation. Delivery times are minimized to ensure product integrity during transit. |
| Storage | Fluo 3-AM should be stored desiccated and protected from light at –20°C or below. The vial must be tightly sealed to prevent moisture absorption and degradation. Avoid repeated freeze-thaw cycles, and let the vial equilibrate to room temperature before opening to minimize condensation. Proper storage ensures stability and consistent fluorescence performance in calcium imaging experiments. |
Applications of Fluo 3-AM in Industrial ManufacturingFluo 3-AM serves as a specialized calcium ion indicator in the biopharmaceutical, cell research, diagnostics, and high-content screening sectors. As a direct manufacturer, we supply high-purity batches supporting precise end-use requirements, with consistent performance in validated downstream applications. Below, we detail the main industrial sectors utilizing this compound, highlighting standards, formulation practices, manufacturing processes, and finished goods integration. 1. Live Cell Calcium Imaging in Biopharmaceutical R&DResearchers rely on this calcium-sensitive fluorescent indicator for live cell imaging and intracellular calcium tracking in advanced drug discovery and pharmacological profiling. Used in both small molecule and biologic development pipelines, its AM ester form enables efficient cell loading and rapid workflow integration during high-throughput screening. Our production supports rigorous quality documentation for regulatory submissions and audit trails required by industry leaders. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Flow Cytometry Assays in Immunology ManufacturingIn immunological product pipelines, this fluorescent dye supports real-time monitoring of lymphocyte activation and intracellular signaling during flow cytometry-based quality control and contract assay development. Known for its proven compatibility with multi-color panel designs, it maintains sensitivity and reliable gating even when integrated into complex analytical workflows for immune cell phenotyping. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Calcium Signaling Analysis in Neuroscience Tool ProductionNeuroscience research instrument makers formulate buffer and imaging kits using this compound for detecting rapid calcium flux in neuronal cultures and brain slice preparations. It is recognized for supporting large-scale neuroactivity mapping and real-time pharmacological response profiling during both instrument calibration and commercial kit assembly, where trace purity and low batch variance are critical. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. High-Content Screening System ConsumablesManufacturers of automated high-content imaging systems integrate this fluorescent indicator as a critical reagent in consumable plate kits and validated protocols. Its reproducible fluorescence lifetime and broad compatibility with robotic liquid handlers facilitate direct adoption into QC-validated imaging runs, ensuring precise calcium detection during batch release of commercial plates and live cell consumables. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive (Fluo 3-AM) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Producing Fluo 3-AM brings us back to the needs that launched fluorescent cell imaging in modern laboratories. Every batch we produce reminds us: reliability in cellular fluorescence doesn’t happen by accident. We put real muscle behind technical consistency, batch reproducibility, and purity during the preparation of Fluo 3-AM. As a direct manufacturer, we observe firsthand how even minor changes in formulation impact detection results. We realized years ago that labs—big and small—use Fluo 3-AM to map real-time calcium flux in cells, demanding sharp sensitivity down to the sub-micromolar level. Researchers working with neurons, cardiomyocytes, and plant cells have relied on our batches to capture calcium transients during live-cell imaging, patch-clamp recordings, and high-content screening.
Producing Fluo 3-AM is not a generic run. This acetoxymethyl (AM) ester derivative of Fluo 3 transforms how labs observe dynamic calcium changes within live cells. The nonpolar AM ester allows Fluo 3-AM to slip effortlessly through cell membranes, in stark contrast to polar, membrane-impermeant forms. Once inside, endogenous esterases cleave the AM groups, yielding active Fluo 3 which binds Ca2+ ions and emits robust green fluorescence. We see tech staff run quality batches on HPLC, tracking purity, and making sure the molecule displays its hallmark excitation (∼506 nm) and emission (∼526 nm) peaks without background drift. Field feedback points out that batch-specific spectral purity determines signal-to-noise ratio, and subtle tweaks in the manufacturing process translate directly into background autofluorescence or poor cell loading. Our chemical engineers, always rooting out process drift, insist on fresh calibration and validation before every fill.
Down the years, our customers taught us not to cut corners. Labs working on confocal, flow cytometry, and plate-based imaging depend on Fluo 3-AM’s compatibility with different platforms. The format we manufacture has earned trust for its solubility in DMSO and Pluronic F-127, offering consistent results whether loading adherent or suspension cells. Researchers note faster dye loading and brighter calcium responses compared to older-generation dyes. This leap in responsiveness means that transient Ca2+ spikes in stimulated synapses or muscle contraction experiments never get missed. Every container is filled and shipped under low moisture and light, as performance quickly drops with water vapor and UV exposure. We built dedicated lines for aliquoting to minimize operator contact, preserving dye potency until it lands on the customer’s bench.
We’ve seen both new and veteran researchers weigh Fluo 3-AM against Rhod-2 and Fura-2 AM, all workhorses for calcium assays. Each dye stakes out its own territory, but distinctions affect daily research. Fluo 3-AM stains cytosolic calcium with sharp green fluorescence that avoids red-channel overlap, which means less crosstalk in multi-label experiments. Rhod-2 AM, for instance, targets mitochondria and emits in the red, but comes up short for anyone tracking rapid cytoplasmic Ca2+ shifts. Fura dyes deliver ratiometric data and stronger resistance to dye leakage, yet their UV excitation exposes cells to potential photodamage. Technicians regularly mention that Fluo 3-AM’s visible-range excitation spares equipment and cell viability during repetitive time-lapse studies.
We encourage direct feedback, whether from university core labs or pharma biologists running massive screening routines. Over the years, seasoned researchers highlighted some long-standing pain points with commercial batches elsewhere—erratic dye loading, batch-to-batch variability, and sudden signal drops. Our own experience drove us to standardize every step, from precursor synthesis to final lyophilization. For challenging cell types, such as primary neurons or plant protoplasts, minor changes in the formulation—like the ratio of AM ester to active acid—markedly change dye retention and background levels. Each customer troubleshooting call nudges us to adjust our process and packaging next time. Our in-house support team works alongside the synthesis crew, running side-by-side dye loading and calcium stimulation tests before every large shipment hits the road.
Producing Fluo 3-AM has taught us about the fragility of fine chemical logistics. The dye’s sensitivity to hydrolysis and oxidation cannot be overstated—left exposed to ambient air, it degrades fast, losing potency. That's why we've invested in argon-flushed ampoule filling lines for our highest-grade lots. We field-test each lot for its cell permeability and intracellular retention by loading sensitive cell models. Spec changes arise not by whim, but from the accumulated suggestions of scientists in the trenches. For example, after repeated requests, we began supplying includes small DMSO pre-dilution vials to help reconstitute fluo dyes without introducing water and risking premature hydrolysis. Such incremental tweaks only come from long-term engagement with research users, not distributors far from the bench.
The last five years brought a new wave of applications that stretch the original conception of Fluo 3-AM. High-content phenotypic screening, toxicity profiling, and neural network activity assays all bank on the quick, clear shifts in cytoplasmic calcium visualized by these dyes. Customer collaborations in cardiovascular research showed us how Fluo 3-AM can be cycled through hundreds of wells per hour for drug safety screens. Its dependable cell loading and low toxicity opened the door for lengthy, real-time recordings in sensitive cardiac and neural tissue explants. Working with agricultural research groups, we also tuned lot characteristics to match plant cell loading needs, identifying trace impurities that slow dye uptake or inject cytotoxicity during critical developmental windows.
Each production run presents familiar challenges. Small changes in reagent sources can bump up background fluorescence or reduce cell entry. We run in-house imaging tests on each lot, partnering with academic labs for third-party validation before large-scale release. Curious researchers often ask about our fluorescence intensity controls and impurity profiles. Instead of generic certificate printouts, we ship each lot with genuine testing data for common mammalian, yeast, and plant cell types. We learned that users prefer proof over promises—plots and microscope images tell the true story of how a dye performs. Of course, product purity and stability monitoring extend beyond the certification desk: our bench scientists routinely monitor old retained samples to flag shelf-life shifts and offer replacements before quality dips.
Fluo 3-AM, by its design, faces limitations just like every live-cell dye. Some cell types, especially those rich in efflux pumps, spit out dye quickly, losing signal strength. Our technical team recommends multi-step loading protocols or the use of pump inhibitors for these stubborn models, and we've witnessed firsthand how even slight tweaks can extend tracking windows. Other labs bumped into photobleaching or cytotoxicity at high concentrations—a reality in fast, repeated high-intensity imaging. This leads us to stress proper calibration in your setup, backed up by our cross-platform validation data. We listen to users, adapt our in-house handling guides and keep pushing to reduce residual hydrophobic impurities, aiming for minimal toxicity and consistent, strong fluorescence.
It’s easy for non-manufacturers to focus solely on purity certificates and spec sheets. As chemical makers, we scrutinize every step. Lyophilization must leave minimal moisture. Container sealing must preserve long-term stability, not just pass an initial shelf test. Cooling and shipping schedules respond to real-world weather delays that might swap performance for logistics convenience. We've engineered tamper-proof seals and extra-dark bottles following up direct user warnings about light leaks, choosing practical over pretty packaging. One poorly sealed vial can break trust built over years. We reward sharp-eyed users who flag even minor labeling confusion or packaging slips so we can tighten up every future shipment, down to the smallest lot.
As the actual manufacturer, controlling every operation grants us clarity and accountability impossible for resellers juggling dozens of supply sources. We react to real signals from the bench—feedback, shipment issues, and surprising research applications. Recent requests for larger economy sizes came from lab teams screening thousands of compounds. We implemented bulk packaging with improved vacuum desiccation just to address this need, refusing to offload excess moisture risk onto the end user. Direct batch inventory keeps us nimble: we investigate signal loss, cloudiness, or strange precipitation, drawing on archived lots, not stories from a distant wholesaler.
Emerging technology always spurs us to improve. Super-resolution microscopy and optogenetics now stretch our standards for photostability and spectral sharpness. User requests for multiplexed assays push us to test for crosstalk and fluorescence overlap between Fluo 3-AM and newer red and far-red indicators. Batch reproducibility isn’t just marketing—calcium kinetics vary lot by lot with even slight impurity changes, making our in-house chemists sweat the microdetails. We’re investigating novel esterase-cleavable designs to boost speed and cell retention, building on our direct manufacturing insight.
Standing behind Fluo 3-AM, we know every test, every lot, every container. We source, purify, and verify under the eyes of our own experts. We appreciate the users who trust their experiments to our dye and who push us for greater transparency, new forms, and ever higher standards. True, the work never feels finished, and small issues in dye loading or background fluorescence matter deeply to us. We treat each complaint, suggestion, and unusual use case as an opportunity to adapt our process—forging a better, more reliable essential tool for every scientist working to illuminate the mysteries of calcium signaling inside living cells.