HS Code |
936571 |
| Chemical Name | Ferroin |
| Full Name | 1,10-Phenanthroline iron(II) complex |
| Molecular Formula | [Fe(phen)3]2+ |
| Molar Mass | 692.56 g/mol |
| Appearance | Red-orange solution |
| Solubility In Water | Soluble |
| Use | Redox indicator |
| Color Of Oxidized Form | Pale blue |
| Color Of Reduced Form | Red |
| Stability | Stable in dark, decomposes in strong light |
| Cas Number | 14708-99-7 |
| Concentration In Solution | Typically 0.025 M |
| Sensitivity | Sensitive to oxidizing/reducing agents |
| Toxicology | Harmful if swallowed |
| Storage Conditions | Store in cool, dark place |
As an accredited Ferroin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Ferroin is supplied in a 100 mL amber glass bottle with a secure plastic cap, featuring clear hazard and usage labeling. |
| Shipping | Ferroin, a common redox indicator, should be shipped in tightly sealed containers to prevent contamination and degradation. It must be clearly labeled and protected from physical damage, excessive heat, and direct sunlight. Conform to applicable regulations for chemical transport, including appropriate documentation and packaging to ensure safety during transit. |
| Storage | Ferroin should be stored tightly sealed in a cool, dry, and well-ventilated area, away from light and incompatible substances such as strong oxidizers. The container should be clearly labeled and kept away from heat sources. It is important to avoid exposure to moisture and to handle the chemical using appropriate protective equipment to prevent contamination or deterioration. |
Applications of Ferroin in Industrial ManufacturingFerroin, as a 1,10-phenanthroline iron(II) complex, serves unique and highly specific roles in analytical, chemical synthesis, and quality control processes across multiple specialized industries. Our manufacturing experience ensures consistent purity and reliable supply for downstream users requiring precise formulation integration. Below, we outline authentic industrial application scenarios with detailed compliance and practical guidance. 1. Water Quality Testing Reagent ProductionIndustrial producers of reagent test kits utilize ferroin as a redox indicator for both manual and automated water analysis, where rapid and distinct color change endpoints determine chemical oxygen demand (COD) and other oxidant concentrations. The reagent formulation balances indicator stability against shelf-life and endpoint visibility under variable sample matrices. Production facilities incorporate rigorous contamination controls and batch standardization to meet regulatory mandates for traceable water analysis. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Teaching Chemical Reagent ManufacturingEducational reagent suppliers require highly stable ferroin solutions for use in laboratory instruction kits, particularly for redox titration demonstrations and instructional experiments on reaction kinetics. Formulation prioritizes long-term color retention, batch-to-batch consistency, and safe dilution for direct classroom use, ensuring compliance with chemical handling standards in academic and research settings. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Laboratory Analytical Indicator Solution ProductionSpecialty laboratory chemical manufacturers produce high-purity ferroin indicator solutions for use in complexometric analysis, colorimetric endpoint detection, and advanced titration protocols. Quality protocols require precise control of iron(II) to phenanthroline ratios, exclusion of iron(III) impurities, and meticulous packaging to support downstream applications in certified testing labs and quality control divisions within pharmaceutical and environmental sectors. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Research-Grade Chemical Kit AssemblyChemical kit assemblers integrate ferroin indicator solutions into research and diagnostic sets designed for kinetic studies such as Belousov-Zhabotinsky oscillating reaction experiments. Strict adherence to research chemical purity levels and complete documentation for trace element content are essential, supporting reproducibility in high-precision industrial R&D and academic research labs. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Pharmaceutical Quality Control Reagent ProductionPharmaceutical quality control laboratories use ferroin solutions as visual endpoint indicators for titration analysis of active pharmaceutical ingredients and excipients in accordance with pharmacopeial test methods. Manufacturing focuses on trace metal purity, consistent colorimetric response, and contamination-free bottling, with batch records supporting cGMP compliance throughout the supply chain. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive Ferroin prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Every production run brings new challenges in analytical chemistry, and our experience manufacturing Ferroin has taught us what makes this indicator truly stand out. Ferroin, or 1,10-phenanthroline iron(II) sulfate complex, is more than a redox indicator. In our facility, we focus on batch consistency, color clarity, and purity.
To us, Ferroin isn’t just a chemical solution; it’s a carefully crafted tool for analysts and researchers. Quality hinges on several factors: the strength of the ruby-red hues in its reduced state, the sharp transition to blue when oxidized, and the stability during storage and handling. Our most requested model is the 0.025 mol/L (0.025N) solution, favored for both classic titrations and research-grade experiments. We know from hands-on work that even slight variations in reagent concentration or purity will show in your titration endpoint. We keep tight control on the ratio of 1,10-phenanthroline to iron(II), since this chemistry underpins color sensitivity and oxidation-reduction reversibility.
Several decades of synthesis and packaging experience have shaped how we make Ferroin. We source high-grade 1,10-phenanthroline and iron(II) sulfate heptahydrate, dissolving them in deionized, filtered water under nitrogen. Careful exclusion of oxygen preserves iron in the Fe(II) oxidation state until you use it. Bottling in amber glass and purging with inert gas extend shelf life and preserve the sharp red color essential for endpoint clarity in titrations.
Shipping and storage can challenge the quality of many indicators. From lab feedback, we learned that exposure to air, light, or trace oxidants can dull the color and shift the response profile. We train our staff not just in batch synthesis but in every fine detail from capping bottles tightly to checking UV protection on every shipment. Mistakes here show up clearly in test results—a pale Ferroin solution reflects on everyone involved in the process. Our manufacturing team stands by each lot because quality control is integral, not adjunct.
In metallurgical analysis, water testing, and educational labs, Ferroin remains critically important. Common applications include its role as a redox indicator in the titration of iron(II) with cerium(IV) or dichromate. Technicians trust the sudden color change at the endpoint—a vivid shift from deep red to pale blue. Our largest industrial and academic customers rely on that transition because their analytical results depend on it. Laboratories using automatic titrators or manual burettes want the same reliability and visual sharpness, and batch after batch, our solution delivers.
Some clients working with environmental samples report strong resistance to interference, even in water or soil matrices with organic residues. That didn't come about by accident. During in-house validation, we exposed Ferroin to typical urban and rural water contaminants and measured its response precision. Our batches retained stable performance in various real-world matrices, which speaks to component purity and control over trace impurities.
Specialized users in chemical education appreciate the strong color response for lecture demonstrations—students, even in the farthest row, witness the sharp endpoint thanks to our focus on color yield. In research settings, our Ferroin provides confidence for kinetic studies of oscillating reactions—the classic Belousov-Zhabotinsky reaction being just one celebrated example. Loosely prepared or impure indicator solutions can dampen oscillations or blur the visual boundary—a problem avoided with a steady supply of well-made product.
Choosing the right indicator for redox titration requires more than habit. Some labs shift to diphenylamine sulfonate or starch-iodide systems, but the visual clarity of Ferroin often persuades analysts to return. Alternatives might provide adequate performance in specific settings, but feedback from our users highlights why they return to Ferroin: minimal subjective interpretation at the endpoint, resistance to photodegradation, and robust handling. We’ve heard from lab managers who switched after lower cost indicators introduced ambiguity and cost them in quality assurance workload.
Starch for iodometric titration yields a stark blue-black with iodine but misses in several metal-ion redox titrations where interference is strong or sample coloring obscures the signal. Diphenylamine sulfonate, while sensitive, tends to degrade faster in light and can require special care in storage and preparation. By contrast, our optimized Ferroin batch keeps for extended periods and maintains color response even under moderate laboratory handling. This saves time on re-standardization and lowers burden on laboratory SOP revisions.
We often field questions about using Ferroin solutions supplied by various traders or laboratories who make up “in-house” batches, sometimes titering from technical-grade materials. Those solutions seldom match the batch-to-batch reproducibility and pure color contrast we deliver. Our manufacturing runs use analytical and pharmacopoeia-grade inputs; lab-prepared concoctions or solutions made from technical-grade ingredients can include trace metals or by-products, muddying the red-blue transition and diminishing endpoint sharpness. In critical applications—such as pharmaceutical QA testing or regulatory laboratory audits—that uncertainty comes at a price. Analytical results swing, and repeatability suffers.
Most end users focus on concentration and volume, but we take special care with quality benchmarks that only show in routine testing. Each batch undergoes titration validation against standard cerium(IV) solutions to certify detection sensitivity and color transition at the benchmark endpoint. We measure pH and examine stability over several weeks under light and air to establish real-world handling durability. Spectroscopy on the finished product checks optical density and color profile at key wavelengths around 510 nm (for the ferrous complex) and in the 600-620 nm range (for the oxidized state). We work closely with our raw material suppliers, running joint impurity checks—especially for trace metal cations that may catalyze unwanted side reactions or dull the indicator’s sharpness.
For our standard solution (0.025 mol/L), accuracy of concentration comes down to careful, gravimetric addition at every step. We calibrate balances and validate volumetric glassware routinely. Feedback from our own and external laboratories has confirmed that our Ferroin solution gives clear, reliable color changes in both dilute and more concentrated titrations. This color transition remains unmistakable even when dealing with compounds prone to light scatter or colloidal suspension, which would otherwise harbor risk for ambiguity using lower-purity indicators.
Occasionally, advanced users request custom concentration ranges or bulk quantities for process analytics, industrial water treatment, or research projects. We handle these orders with special lot tracking and increased documentation, maintaining the same input purity and traceability. Our approach is not just about hitting a spec sheet—it’s grounded in collaboration with end users, providing flexibility without compromising the chemical performance.
Industry-wide, oxidation remains a challenge for storing iron(II) complexes. From years of troubleshooting alongside our clients, we recognized storage under nitrogen or argon, use of amber glass, and controlled temperature provide the longest shelf life. We issued firm handling guidelines—keep sealed, avoid warm storage areas, and never pour unused indicator back into the stock bottle. We reinforce with training, providing technical bulletins based not on theory but on direct feedback from real laboratory fieldwork.
A recurring problem among chemical suppliers involves incomplete dissolution or presence of suspended material. Sometimes this comes from suboptimal 1,10-phenanthroline quality or from careless mixing protocols. We invested in in-line filtration and high-shear mixing during production, then followed with final batch inspection under both transmitted and reflected light. Clear, particulate-free solution raises laboratory trust—and repeat orders prove it pays off.
For sustainability, some users express concern about environmental impact, especially when handling larger volumes. Our operation includes solvent management and waste minimization practices, avoiding unnecessary disposal of iron-rich solutions by encouraging titration on demand and supplying product in volumes sized for rapid turnover. Bottles, caps, and liners meet regional recycling requirements. Our plant manages ferrous and phenanthroline residues through verified waste streams, reducing risk of waterway contamination.
Our customer relationships run deeper than a single purchase. Detailed technical discussions with users—often analytical technicians and lead chemists—brought forward ideas that shaped our best practices. We learned that simple label improvements prevented mix-ups on crowded reagent shelves. QR codes on bottles now link to batch certificates and validation reports. Some educational partners wanted pre-measured ampules or pipette-friendly caps to reduce spillage; those features are now standard on select volumes. One feedback session with a government water analysis lab resulted in tighter batch variance specifications to tighten financial audit trails.
We regularly participate in proficiency-testing schemes using our own product, seeing firsthand how well our Ferroin stands up in interlaboratory comparisons. This keeps our team grounded; every test run tells us where quality meets expectation and where a tweak can deliver even greater reliability. Sharp feedback, often in the form of field test data, prompted us to boost trace metal screening and enhance bottle rinsing protocols—small improvements, but worth the effort when matrix effects are a concern.
Meeting analytical-grade requirements compels transparency and record-keeping. We generate batch certificates detailing production date, expiry forecasts, raw material certificates, and results from titrimetric standards. Regulatory compliance is more than paperwork—it comes from discipline at every step. Our plant’s procedures comply with ISO guidelines on chemical manufacture, and raw material traceability spans from supplier verification to final shipment logs. We’re not immune to inspections; in fact, our doors have welcomed auditors from educational institutions, environmental authorities, and pharmaceutical analysts.
We avoid cross-contamination scrupulously. Ferroin preparation runs in a dedicated suite, separated from dye or indicator production lines where color cross-over could threaten analytical purity. Technicians rotate between stations with clearly segregated clean-room attire, and every batch receives a double-check on both color and clarity before shipping. This layered vigilance finds its roots in audit results and user returns monitored over years, not just in policy manuals.
As a chemical manufacturer, our relationship with Ferroin is lived through regular production, quality testing, and support for end-users facing tight performance targets. From small batch runs for academic research to large industrial consignments, we measure product success by the feedback and repeat orders that follow. Claims about shelf stability, color consistency, and handling ease grew from repeated, real-world observation in laboratories, reinforced by internal and external validation.
Feedback loops are direct and sometimes blunt. One environmental water-testing site called out a lot where color response faded after six months in sunny window storage; we ran internal stress tests, confirmed light sensitivity above a certain threshold, and shifted to thicker amber glass and improved secondary packaging. That move improved not only product lifespan but also user satisfaction rates. At every production review, we bring up stories from the field—positive and negative—because we know today’s minor issue turns into tomorrow’s opportunity for improvement.
Manufacturing and supplying Ferroin does more than fill a catalog page—it challenges us to keep learning and testing. Each year, analytical expectations grow sharper, and detection limits drop. Users push indicators into new applications—micro-volume titrations, in-situ environmental monitoring, automated analyzers. We invest in R&D and collaborative trials, so that adjustments—whether in formulation, packaging, or documentation—take shape ahead of formal requests.
Growth in chemical manufacturing comes from genuine transparency, iterative improvement, and constant dialogue with our user base. That cycle drives the steady enhancement from each batch of Ferroin on our line. We carry lessons from every technical support call, lab visit, and audit report back to the production floor. Our reputation depends not just on selling a solution but on making sure that, in laboratories across the country and beyond, the simple but striking change from red to blue delivers clarity in every measurement.