Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Dimethyl Popop

    • Product Name Dimethyl Popop
    • Alias Bis-MSB
    • Einecs 249-817-0
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    269167

    Chemical Name 1,4-Bis(1-phenylethyl)-2,5-dimethoxybenzene
    Common Name Dimethyl Popop
    Molecular Formula C24H26O2
    Molecular Weight 346.46 g/mol
    Cas Number 59669-45-9
    Appearance White to off-white powder
    Solubility Soluble in organic solvents such as ethanol and benzene
    Melting Point 93-95°C
    Fluorescence Emission Maximum 430 nm (in ethanol)
    Usage Scintillation fluor in radiation detection

    As an accredited Dimethyl Popop factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Amber glass bottle labeled "Dimethyl Popop, 25g." Secure screw cap, chemical hazard symbols, and manufacturer information are present on the label.
    Shipping Dimethyl Popop is shipped in tightly sealed containers made of chemically resistant materials to prevent contamination and moisture intrusion. Packages are clearly labeled according to regulatory standards, including hazard classifications. It is transported under controlled conditions, away from incompatible substances, with accompanying safety documentation to ensure safe and compliant handling during transit.
    Storage Dimethyl Popop should be stored in a tightly closed container, kept in a cool, dry, and well-ventilated area away from incompatible substances such as strong oxidizers. Protect it from light and moisture, and avoid sources of ignition. Clearly label the container, and ensure proper secondary containment to prevent spills. Always refer to the SDS for detailed storage recommendations.
    Application of Dimethyl Popop

    Applications of Dimethyl Popop in Industrial Manufacturing

    Dimethyl Popop serves as a specialty intermediate in several advanced industrial sectors. Our material undergoes strict in-house quality controls for reliable integration into downstream customer processes. Below are key application fields, each reflecting real-world commercial usage and the precise technical requirements encountered by end manufacturers.

    1. Scintillation Detector Manufacturing

    High-performance particle detection systems frequently require organic scintillators with custom emission profiles. Dimethyl Popop functions as a wavelength shifter in plastic or liquid scintillator fabrication, enhancing sensitivity and time resolution in advanced detector modules for physics research, nuclear safety, and medical imaging. Integrated during scintillator casting or mixing, it allows manufacturers to adjust photon yield and emission spectrum to strict detection requirements, while maintaining batch reproducibility and radiation hardness throughout the process chain.

    Industry compliance standards

    • ASTM E263–14 (Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Aluminum)
    • IAEA Safety Standards Series No. GSR Part 3 (Radiation Protection)
    • ISO 11929 (Determination of the characteristic limits for measurement of ionizing radiation)
    • Cleanroom requirements per ISO 14644-1 for assembly, where required

    Typical usage ratio

    • 0.01–0.2% w/w in organic solutions, with concentration optimized based on required light output and thickness of the matrix; elevated levels only for high-energy detectors

    Downstream process integration

    • Incorporated into monomeric solution or melted polymer before polymerization or casting; mixed with other fluors and solvents prior to molding or extrusion

    Final product types

    • Plastic scintillator rods and plates
    • Liquid scintillation cocktails for laboratory analyzers
    • Solid-state radiation detectors for medical imaging (PET, gamma cameras)
    • Detector arrays for high-energy physics experiments

    2. Environmental Analytical Consumables

    Laboratories producing specialized analytical kits for radioisotope quantification rely on wavelength shifters to increase the sensitivity of light detection in water or soil sample testing. The material’s high quantum efficiency and defined spectral shift profile allow for the precise calibration of photomultiplier tubes and the minimization of background noise, which is vital for compliance in environmental trace analysis. Direct addition to solvent blends during batch formulation supports consistent performance across kit lots, which undergo validation against regulatory protocols.

    Industry compliance standards

    • US EPA SW-846 Methods (Test Methods for Evaluating Solid Waste–Physical/Chemical Methods)
    • ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
    • OECD GLP Principles (Good Laboratory Practice for Chemicals)
    • EN ISO 5667-20 (Water quality — Sampling — Part 20)

    Typical usage ratio

    • 0.005–0.05% w/v, based on matrix composition and detection limits required for regulatory methodologies

    Downstream process integration

    • Blended into organic solvent cocktails during formulation; filtered and aliquoted per specific protocol batch; subjected to light emission calibration pre-packaging

    Final product types

    • Scintillation cocktail reagents for radiometric analysis
    • Premixed analytical vials for use in liquid scintillation counters
    • Calibration standards for tracer and isotope applications

    3. Medical Device Component Fabrication

    Dimethyl Popop contributes to the manufacture of internal optical components in certain diagnostic medical devices that require precise energy conversion for photodetection, such as positron emission tomography (PET) scanners. Incorporated during the formulation of the optically active layer or solid matrix, the material’s role includes stabilizing emission wavelength for consistent device calibration over repeated cycles. Integration requires adherence to stringent quality standards, including biocompatibility assurance for internal instrument parts that may contact reagents.

    Industry compliance standards

    • ISO 10993 series (Biological evaluation of medical devices)
    • ISO 13485 (Medical devices — Quality management systems)
    • RoHS/REACH for restricted substances
    • FDA 21 CFR 820 QSR (Quality System Regulation for Medical Devices, in US markets)

    Typical usage ratio

    • 0.01–0.1% by weight in device polymers, with trace levels carefully controlled to ensure consistent photodetection performance and non-reactivity

    Downstream process integration

    • Added during compounding or pre-molding stage of optical-grade plastics or coatings; homogeneously dispersed in resin prior to extrusion or injection molding

    Final product types

    • Scintillator panels and optical layers in PET/CT equipment
    • PMT-adjacent films and encapsulated detector modules
    • Medical imaging sensor blocks

    4. Industrial Safety Monitoring Devices

    In manufacturing of neutron or gamma radiation dosimeters for workplace safety, Dimethyl Popop is essential in cost-effective, reliable plastic-based sensor elements. Manufacturers incorporate it into fabricated polymeric substrates, optimizing detection capabilities for real-time exposure monitoring. The formulation process factors in regulatory mandates regarding radiation detection thresholds for occupational environments, ensuring units consistently meet minimum detection requirements post-fabrication and device assembly.

    Industry compliance standards

    • IEC 61526 (Radiation protection instrumentation — Measurement of personal dose equivalents)
    • EN 62387 (Passive integrating dosimetry systems for environmental and personal monitoring)
    • ISO 4037-3 (X and gamma reference radiations for calibrating dosimeters)
    • National standards per OSHA 29 CFR 1910.1096 (Ionizing Radiation, US Workplace Regulations)

    Typical usage ratio

    • 0.008–0.05% in prepared plastic matrices, with levels calibrated to maximize light yield without introducing background instability over device lifetime

    Downstream process integration

    • Introduced at polymer feedstock mixing stage; subjected to extrusion and physical shaping before device encapsulation and electronics integration

    Final product types

    • Personal radiation dosimeters
    • Environmental radiation monitoring badges
    • Industrial safety handheld counters and sensors

    5. Scientific Instrumentation Components

    Optical modules for laboratory-grade spectrometers and fluorescence measurement devices integrate Dimethyl Popop within their internal calibration kits or sample holders to generate reproducible emission for internal photodetector alignment or performance validation. Producers rely on its defined photophysical characteristics for strict standardization, ensuring each instrumentation piece meets calibration traceability and instrument QC benchmarks. The role as a wavelength standard guarantees device reproducibility and lifetime performance in line with manufacturer warranty commitments.

    Industry compliance standards

    • ISO/IEC 17025 (General requirements for laboratory calibration)
    • JIS K0050 (Japanese Standard for Spectrophotometry)
    • EN ISO 8655 (Piston-operated volumetric apparatus verification)
    • US NIST traceable calibration standards for light sources and detectors

    Typical usage ratio

    • 0.01–0.04% in solid sample holder matrices, or as specified by instrument manufacturers’ proprietary calibration guidelines

    Downstream process integration

    • Integrated during molding or lamination process for sample cups and internal calibration references; also dissolved in carrier for calibration kit assembly

    Final product types

    • Spectrometer calibration modules
    • Reference chips for fluorescence readers
    • Instrument QC panels for in-line quality verification
    Free Quote

    Competitive Dimethyl Popop prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance