Chengjiang, Yuxi, Yunnan, China sales1@sinochem-nanjing.com
Follow us:

Cholesterol N-Valerate

    • Product Name Cholesterol N-Valerate
    • Alias Cholesteryl pentanoate
    • Einecs 256-886-5
    • Mininmum Order 1 g
    • Factory Site Chengjiang, Yuxi, Yunnan, China
    • Price Inquiry sales1@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    607728

    Productname Cholesterol N-Valerate
    Casnumber 604-09-1
    Molecularformula C32H54O2
    Molecularweight 470.76 g/mol
    Appearance White to off-white powder
    Meltingpoint 94-98°C
    Solubility Insoluble in water; soluble in organic solvents
    Storagetemperature 2-8°C
    Purity Typically ≥98%
    Synonyms Cholesteryl pentanoate
    Iupacname cholest-5-en-3β-yl pentanoate
    Smiles CCCCC(=O)O[C@H]1CC[C@@H]2[C@]1(CC[C@H]3[C@H]2CC=C4[C@@]3(CC[C@@H](C4)OCCCCC)C)C

    As an accredited Cholesterol N-Valerate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Cholesterol N-Valerate, 1 gram, supplied in a clear glass vial with screw cap, labeled with product details and safety information.
    Shipping Cholesterol N-Valerate is shipped in secure, sealed containers, typically under ambient temperature unless otherwise specified. Packaging complies with chemical safety regulations to prevent leaks or contamination. Accompanying documentation includes safety data sheets and labeling in accordance with transport guidelines for non-hazardous laboratory chemicals. Handle with care during transit and storage.
    Storage Cholesterol N-Valerate should be stored in a tightly sealed container, protected from light and moisture. Keep it at a temperature of 2-8°C (refrigerated) and in a well-ventilated area. Store away from incompatible substances, such as strong acids, bases, and oxidizing agents, to maintain stability and prevent decomposition. Always handle using appropriate laboratory safety protocols.
    Application of Cholesterol N-Valerate

    Applications of Cholesterol N-Valerate in Industrial Manufacturing



    Cholesterol N-Valerate finds specialized applications as a functional intermediate and ingredient in several advanced manufacturing sectors. As direct producers of this compound, we support industries that require defined cholesterol ester profiles for process performance, regulatory compliance, and specific product attributes. Below are the key downstream applications, each reflecting actual industrial demand and usage patterns.



    1. Liposome and Nanocarrier Formulation (Pharmaceuticals)



    Pharmaceutical manufacturers use Cholesterol N-Valerate to customize the membrane characteristics of liposomes and nanoscale drug carriers, focusing on encapsulation efficiency, controlled payload release, and enhanced stability for parenteral formulations. By adjusting the cholesterol ester composition, formulators control vesicle rigidity and permeability for products that target precise bioavailability profiles during pre-clinical and commercial production runs.


    Industry compliance standards



    • USP Liposome Injection Monograph

    • ICH Q7 Good Manufacturing Practice for Active Pharmaceutical Ingredients

    • European Pharmacopoeia 10.0 — General Monographs for Excipients

    • FDA 21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals


    Typical usage ratio



    • 1%–12% w/w of total lipid phase; formulators adjust concentration depending on desired rigidity, drug loading, and release kinetics for each drug product line.


    Downstream process integration



    • Raw material addition during lipid film hydration or solvent injection stage; incorporated with phospholipids before hydration or ethanol injection to facilitate uniform ester and phospholipid mixing while minimizing degradation during downstream size-reduction steps (extrusion and sonication).


    Final product types



    • Liposomal anticancer injectables

    • Nanoscale vaccine carriers

    • Ophthalmic liposome suspensions

    • Subcutaneous long-acting injectable depots



    2. Cosmetic Emulsion Stabilizers (Skincare and Cosmetics)



    Personal care and cosmetic companies integrate Cholesterol N-Valerate to replicate natural skin lipid fractions, particularly in premium moisturizers and barrier creams aimed at sensitive skin types. This ester serves both as an emollient and as a membrane-structuring agent, which supports stable emulsions and enhances the delivery of actives such as ceramides and fatty acids. Manufacturers value its precise melting characteristics and ability to improve spreadability without clogging skin pores.


    Industry compliance standards



    • EU Regulation (EC) No 1223/2009 on Cosmetic Products

    • ISO 22716: Cosmetics — Good Manufacturing Practices

    • CTFA (INCI) Ingredient Guidelines

    • Japanese Standards of Quasi-drug Ingredients


    Typical usage ratio



    • 0.2%–4.0% w/w in oil phase; lower inclusion levels for leave-on facial creams, higher for barrier repair formulations.


    Downstream process integration



    • Added during oil phase preparation, typically melted with fatty alcohols and other esters before emulsification; precise temperature control at 60–75°C ensures thorough mixing and prevents hydrolysis during homogenization.


    Final product types



    • Dermo-cosmetic restorative creams

    • Premium facial emulsions targeting sensitive or compromised skin

    • Barrier repair balms and ointments

    • Anti-aging night masks referencing stratum corneum biomimicry



    3. Veterinary Injectable Carriers



    Animal health product manufacturers use Cholesterol N-Valerate as a specialized carrier component in veterinary injectable formulations, particularly for long-acting hormone or anti-parasitic preparations. Its ester form extends release kinetics and maintains suspension stability, which is critical for livestock health products requiring less frequent dosing. Quality parameters must account for injectable-grade purity and endotoxin control due to the risk profile of veterinary parenterals.


    Industry compliance standards



    • Ph. Eur. 10 — Substances for Veterinary Use

    • VICH GL18 — Good Manufacturing Practice for Active Pharmaceutical Ingredients in Veterinary Medicinal Products

    • US FDA Center for Veterinary Medicine (CVM) Injectable Adjuvant Guidance

    • China Veterinary Pharmacopoeia (CVP)


    Typical usage ratio



    • 0.5%–6% w/w of lipid phase; precise level based on the active molecule’s stability and release objectives in livestock or companion animal formulations.


    Downstream process integration



    • Integrated during lipid-solubilization and aqueous phase emulsification, followed by sterile filtration and aseptic filling to preserve ester functionality and sterility.


    Final product types



    • Veterinary extended-release hormone injectables

    • Parenteral anthelmintic depot formulations

    • Intramammary veterinary suspensions for dairy cattle



    4. Research Biochemical Reagents for Membrane Studies



    Specialty biochemical manufacturers source Cholesterol N-Valerate as a control lipid for the construction of artificial membranes in laboratory settings. This compound aids in the simulation of esterified cholesterol behavior in biophysical assays, patch-clamp experiments, and protein interaction studies, providing precise control over membrane fluidity and physicochemical properties relevant for academic, pharmaceutical, and bioscience R&D.


    Industry compliance standards



    • ISO 9001:2015 for Laboratory Chemicals

    • OECD Good Laboratory Practice (GLP) Principles

    • IUPAC Nomenclature and Purity Standards for Research Chemicals

    • REACH Annex XVII (if shipped to EU-based academic sites)


    Typical usage ratio



    • 0.1%–10% molar ratio of total reconstituted lipid in artificial membrane systems; levels vary to explore effects on bilayer properties.


    Downstream process integration



    • Used during vesicle, planar lipid bilayer, or supported membrane preparation procedures, directly mixed with high-purity phospholipids before thin-film hydration or solvent evaporation.


    Final product types



    • Artificial plasma membrane models for ion channel research

    • Reference standard vesicles for drug transporter assays

    • Reconstituted receptor-lipid complexes for biosensor studies

    • Custom liposome kits for laboratory research



    5. Nutraceutical Microencapsulation Systems



    Certain nutraceutical product manufacturers incorporate Cholesterol N-Valerate into complex lipid matrices for the microencapsulation of sensitive bioactives such as fat-soluble vitamins, phytosterols, and carotenoids. This compound helps create multi-layered, oxidation-resistant capsules, which improve ingredient shelf life and targeted release, especially under challenging storage and gastrointestinal conditions.


    Industry compliance standards



    • USDA National Organic Program Standards (if applied in organic formulations)

    • FDA GRAS (Generally Recognized as Safe) Notification Process for Food Ingredients

    • EU Regulation (EC) No 1333/2008 on Food Additives

    • FSSC 22000 Food Safety System Certification for ingredient supply


    Typical usage ratio



    • 0.5%–3% w/w based on total encapsulated oil or bioactive payload; selection depends on core ingredient solubility and stability needs.


    Downstream process integration



    • Incorporated into solubilized lipid phase before microencapsulation step, such as spray-drying, spray-cooling, or coacervation, to ensure even ester distribution and performance throughout capsule formation.


    Final product types



    • Microencapsulated vitamin D3 and E beadlets

    • Powdered omega-3 and phytosterol nutraceutical blends

    • Premix granules for dietary supplement use

    Free Quote

    Competitive Cholesterol N-Valerate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing Cholesterol N-Valerate: A Deep Dive from the Manufacturer’s Perspective

    What Sets Cholesterol N-Valerate Apart in the Lab and Industry

    Every batch of Cholesterol N-Valerate that leaves our facility echoes the value of direct manufacturing expertise. We have worked with cholesterol derivatives for decades, and watching end-users struggle with incomplete or inconsistent esters from unproven sources spurred us to dig deeper than just hitting purity specs. Our Cholesterol N-Valerate reflects this focus—in every lot we deliver, you can see the clarity and consistency that stem from process control, not shortcuts.

    On our floors, synthesis starts with rigorously verified cholesterol, matched to a specific quality profile based on long-standing relationships with veterinary suppliers and animal product processors. This base cholesterol undergoes precise esterification with n-valeric acid, using carefully controlled batch conditions—timing, pressure, and pH never left to guesswork. Skilled technicians log every parameter, not just to pass audits, but because they have learned from years of trial and error the difference bad data makes: the sharp drop in yields, the days lost to rework. The product, as a result, carries a consistency in melting range and color that users notice in the flask, not just in the analyst’s report.

    This hands-on approach pays off for clients. Formulators in pharmaceutical R&D, cosmetics, and analytical reference labs keep reaching out to us because they remember batches that behaved unexpectedly and caused timelines to slip. Many derivatives on the market nominally fit Cholesterol N-Valerate’s structure, but those not produced with strict process discipline show up in the lab as waxy residues, odd odors, or instability. That happens when someone uses lower-grade cholesterol, cuts corners on washing the final product, or tolerates small solvent residues. Over the years, we have traced countless “unexplained” failures in customer projects to one-off producers who didn’t watch the esterification or post-purification steps closely enough.

    Model and Specifications: What We Have Learned Matters

    Chemists ask for Cholesterol N-Valerate by its CAS number and structural fingerprint, but they remember us for what shows up in the bottle. We have standardized our principal model to reflect the needs of both high-throughput pharmaceutical screening and specialized academic research—producing solid, off-white to pale yellow flakes that resist clumping and flow readily. Typical purity exceeds 98 percent by HPLC; we see to it that the melting range remains tight, usually checked against a certified reference. Our internal QC profiles for byproducts, water, and residual solvents go beyond the handful of parameters listed in the literature. We retain control samples and spectral data for years, because mistakes discovered in downstream formulations often trace back to overlooked impurity spikes.

    Our specifications didn’t appear overnight. We collect feedback from long-term clients, many of whom are national lab technicians, industry chemists, and university professors who build their protocols on the reliability of reference materials. Reproducibility—batch to batch, year after year—matters to them. On the manufacturing side, this has led us to tighten our purification sequence, combining repeated crystallization with vacuum drying and multi-stage filtration. People in the know ask if the product’s odor is faint or sharp, a sign of how original cholesterol has been processed and whether any valeric acid lingers. Analytical chemists have confirmed that our product sits well in LC-MS and GC-MS protocols, generating clean profiles and predictable retention times, even at trace analysis levels.

    Usage: Why Quality Drives Results in Applications

    Users rarely get introduced to Cholesterol N-Valerate through a Google search or catalog browsing. Most come to it for one of two reasons: they want a building block for cholesterol-labeled probes in cell biology, or they need an ester with a defined chain length for biochemical or analytical work. In cell membrane studies, Cholesterol N-Valerate integrates into vesicles or monolayers, serving as both a model membrane component and a tracer for metabolic fate studies. In drug discovery, its structure acts as a hydrophobic tag, enabling the creation of analogues or probes that keep the cholesterol core but let chemists tune lipophilicity and chain length.

    We have shipped to teams modifying lipid nanoparticles for mRNA delivery, and learned from long-form discussions with researchers working on enzyme substrate selectivity. They appreciated that our Cholesterol N-Valerate’s well-characterized impurities and consistent melting point removed one variable from their already complex screens. In mass spectrometry, we’ve seen users rely on our material to benchmark fragmentation patterns—subtle differences in prep quality can shift the fingerprint, creating headaches for anyone comparing results across years or between sites.

    Cosmetic chemists order from us for a different reason. Their focus is on incorporating the ester into formulations where texture, spreadability, and long-term stability matter. If trace solvent or excess acid remains, it can trigger discoloration or off-smells in cream or lotion bases. Our direct control over purification has allowed these chemists to hit tight timelines for scale-up and regulatory filing, with fewer setbacks.

    Academic users with tight grant budgets have told us, candidly, that the best deal for Cholesterol N-Valerate isn’t always the one with the lowest unit price. Failure in a membrane simulation or an analytical run can mean weeks lost, not to mention wasted downstream reagents and the risk to student projects or publications. They keep coming back to us because, over dozens of lots, they see lot numbers and documentation that match their reference runs, reducing the stress of troubleshooting unexplained data.

    Differences from Other Cholesterol Esters and Lookalikes

    What sets Cholesterol N-Valerate apart is not just a five-carbon chain on the cholesterol molecule, but the suite of properties this brings for both the user and the manufacturer. Esters of cholesterol—such as oleate, palmitate, acetate, and linoleate—show regular use in research and industry, but each carries its own quirks. Cholesterol N-Valerate fills the middle ground: it resists oxidation better than unsaturated esters like the linoleate or oleate, making it a more stable option for formulations that will spend time on the shelf or undergo heating. In contrast, acetate esters burn off or degrade under conditions that N-Valerate handles with poise, a fact proven in multiple extractables and leachables studies.

    We maintain stocks of other cholesterol esters for comparative testing and often run long-term stability studies side by side. Where palmitate or stearate esters show up as brittle solids or form soft waxes, Cholesterol N-Valerate consistently appears with a powdery texture that disperses easily into both organic solvents and oil-based creams. This may sound minor, but in the blending tanks and vials of our customers, it adds up. Lab techs repeatedly confirm faster solubilization, less batch-to-batch variation in particle size, and less clogging of filters or pipettes.

    On the analytical side, we have observed that contaminants in lower-quality esters mimic the mass spectral patterns and IR spectra of Cholesterol N-Valerate, but not perfectly. Well-trained eyes pick up on small tailing peaks or extra thermal events, especially when derivatives are synthesized from cholesterol that came from less reputable suppliers or shortcuts in acid activation. Market feedback pointed out that esters from “trader” intermediaries rarely stand up to extensive cross-site QA—one researcher recounted how an undocumented contaminant delayed a major lipidomics project until the source was traced back to an poorly-synthesized ester.

    Practical Experience: Manufacturing Challenges, Solutions, and Outcomes

    As a direct manufacturer, we have lived through many of the challenges that separate reliable Cholesterol N-Valerate producers from the rest. Each kilogram produced relies on more than just stainless reactors—success builds on well-structured protocols for sourcing, processing, and verifying cholesterol at every step. Because we use animal-derived cholesterol, our team constantly audits incoming batches for contaminants like pesticides and drugs, not to mention animal-byproduct trace elements. We address these concerns directly with multi-stage purification that does not rely only on single-point column chromatography; we found small impurities can pass through a single step, and catch unsuspecting users downstream. We run elemental analysis on each lot, checking for heavy metals and nitrogenous residues, particularly since these can escape notice in routine IR or UV checks.

    Once esterification begins, process reliability turns into a question of people and time. The crew works in staggered shifts to monitor small sub-batches. This slows production, but avoids the yield losses and quality compromises that come from oversized runs. Untrained labor—common in cut-rate manufacturing—misses endpoint detection, resulting in a higher percentage of unreacted cholesterol or over-acidified product. We have documented how small changes in temperature, pressure, and agitation shift the product profile sharply. By tracking every step, our process chemists avoid the “gray zone” that haunts less careful suppliers: the ambiguous material that nowhere matches a spec but also doesn’t warrant rejection, causing friction downstream.

    After reaction and neutralization, purification turns critical. Each batch passes through multiple solvent rinses, not just the bare minimum. Too many market samples retain traces of acidic or basic catalyst that can trigger false responses in biological assays or damage expensive instruments. Vacuum drying at controlled temperature represents one of our key innovations—we have optimized protocols over years, balancing speed with the need to preserve cholesterol’s sensitive structure. The resulting product holds up on long-term storage, free from the breakdown or yellowing that many academic users report with discount esters.

    Shipping and packaging represent another critical juncture neglected by most traders. Our team only fills in pre-cleaned, inert containers; we draw on years of data about which cap and liner types best prevent moisture ingress or static charge buildup, preserving the product during long overseas hauls. We track inventory age rigorously—any product older than our maximum recommended shelf life gets re-analyzed or disposed, never forwarded to end-users based on cost alone. Many of our repeat customers now specify our packaging or labeling standards in their purchase orders, a sign that transparency and consistency matter on their end as well.

    Why Direct Manufacturer Input Changes the End-User Experience

    Chemists engaged in method development or formulation want more than a COA. They call or email with specifics: Is this lot within two degrees Celsius of the last? Can you guarantee peroxides below a certain level? Do you have NMR or HRMS on file to confirm? Years spent fielding such questions have shaped the way we operate—our lab teams know that speed and specificity matter, document every run, and flag any deviation before the product ever leaves. Where second-layer traders offer vague histories, we provide clear, direct linking of lot numbers, records of storage conditions, and even feedback from previous clients using that batch.

    A recent example involved a pharmaceutical partner needing Cholesterol N-Valerate for combination with radiolabelled materials. Their previous source provided a product that froze out as oily droplets, fouled glassware, and gave inconsistent results on TLC. Our direct involvement in both synthesis and documentation traced their issues to a higher-than-documented valeric acid content compounded by residual solvents from column elution. Within a week, we processed a tighter-recrystallized batch, validated it on both HPLC and GC-MS, and supplied a matched certificate referencing historical assays. Their published work, as a result, cited not just the structure but the lot traceability and documentation. This story is one among many where robust manufacturer involvement made the difference between delay and breakthrough.

    We also work closely with regulatory-affairs teams among our partners. For cosmetic and OTC-drug companies, regulatory landscape can be less forgiving than pure chemical research. We support compliance by offering full traceability documentation, sharing our protocols for animal-origin material handling and exclusion of restricted substances. Our in-house records support fast turnaround for government audits, which has allowed downstream users to secure new approvals in key markets without the stress of protracted supplier negotiations. In an environment where recalls or compliance slip-ups cost real money and reputation, we focus on risk reduction—not just selling kilograms.

    Moving Forward: Sustained Improvement Based on Real-World Feedback

    We see each order of Cholesterol N-Valerate not just as another transaction, but as part of a sustained feedback loop with the scientific community. Scientists send back reports of odd behaviors, product performance, and even new applications. A university proteomics lab once informed us of subtle spectral shifts during high-volume lipid extraction—after back-and-forth discussions and sample runs, we identified and removed a rare byproduct, modifying our purification steps for the next batch. These discussions extend the boundaries of what Cholesterol N-Valerate can achieve, pushing us to tighter quality thresholds and improved analytics.

    Through seminars and site visits, we collect hands-on feedback from teams in biology, analytical chemistry, and industrial product design. Their experiences tell us which performance metrics actually matter in practice—solubility curves, stability during freeze-thaw cycles, odor retention under UV, and others that only arise during extended projects. This continual dialogue helps us refine both production and documentation. While others compete on price, we have chosen to compete on understanding—the in-lab experience, the need for predictable outcomes, the daily realities of method development, and the risks that come from material inconsistencies.

    We are committed to sharing methodological insights and supporting new researchers entering the field. Providing in-depth technical documentation, spectra, and sample data on request, and hosting annual training workshops for analysts, helps us build direct relationships with the next generation of scientists. We are focused on cultivating trust through openness and attention to detail.

    Conclusion: Why Direct Manufacturing Delivers More Than a Product

    Being present at every step of making Cholesterol N-Valerate has shown us the difference between transactional selling and true partnership with labs and manufacturers. From animal-sourced cholesterol verification, esterification process control, to attentive shipping and support, our process is shaped by what end-users need for real, reproducible science. Challenges will always arise as clients push into new applications and tighter specs, but we keep refining our process based on open communication and verified results.

    Cholesterol N-Valerate stands not as just another catalog item, but as the result of daily diligence, a record of feedback from global labs, and the outcome of a manufacturer who cares about what happens after the bottle lands in your hands. In our experience, the difference between a “good enough” batch and a reliable one is all the work that happens before the order is ever placed—work we undertake every day.