Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Bisindolylmaleimide V

    • Product Name Bisindolylmaleimide V
    • Alias Ro 31-8220
    • Einecs 651-111-4
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    814035

    Product Name Bisindolylmaleimide V
    Cas Number 117992-61-9
    Molecular Formula C27H21N3O2
    Molecular Weight 419.48 g/mol
    Appearance Yellow to orange powder
    Solubility DMSO, methanol
    Purity ≥98% (HPLC)
    Storage Temperature -20°C
    Iupac Name 3,4'-Bis-1H-indol-3-yl-1H-pyrrole-2,5-dione
    Synonyms Ro 31-8220
    Usage Protein kinase C inhibitor
    Melting Point 273-274°C

    As an accredited Bisindolylmaleimide V factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Bisindolylmaleimide V is supplied in a 25 mg amber glass vial, sealed with a screw cap and labeled with product details.
    Shipping Bisindolylmaleimide V is shipped in tightly sealed containers under ambient conditions. The packaging ensures protection from moisture, light, and physical damage. It complies with standard chemical transport regulations and is labeled appropriately for safety. Expedited shipping options are available upon request to maintain sample integrity during transit.
    Storage Bisindolylmaleimide V should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and moisture. Keep the container tightly closed and properly labeled. Store at 2-8°C (refrigerated) to maintain stability. Avoid exposure to strong acids, bases, and oxidizing agents. Use appropriate protective equipment when handling, and follow local chemical safety regulations for storage and disposal.
    Application of Bisindolylmaleimide V

    Applications of Bisindolylmaleimide V in Industrial Manufacturing

    As a direct manufacturer, we supply Bisindolylmaleimide V for controlled applications in several specialized downstream sectors. Each sector applies this raw material under targeted conditions, following exact process requirements and compliance standards to achieve reproducible, high-grade end products.

    1. Protein Kinase Inhibitor Development for Research Use

    Pharmaceutical and life science companies use this raw material as a reference inhibitor during the drug discovery process, particularly targeting protein kinase C (PKC) modulation. Laboratories weigh Bisindolylmaleimide V with precise calibration to ensure reliable inhibition profiles in high-throughput screening assays. Controlled storage and batch tracing guarantee traceable origin, critical for GLP and pre-GMP R&D facilities. Integration in research setups demands high purity and stable supply for scale-up and reproducibility across biological evaluation pipelines.

    Industry compliance standards

    • OECD Principles of Good Laboratory Practice (GLP)
    • ISO 9001:2015 for quality management in testing materials
    • REACH Registration for industrial chemicals (EU)

    Typical usage ratio

    • Commonly dissolved at 1–10 μM final concentration in assay buffer per protein target requirements
    • Specific working concentrations decided according to kinase family and cellular model sensitivity

    Downstream process integration

    • Compound introduced after protein extraction and prior to enzyme reaction initiation
    • Added into automated liquid handling for dose-response or inhibitor validation experiments

    Final product types

    • Research-use-only small molecule inhibitor screening kits
    • Cell-based assay reagent sets for kinase pathway studies
    • Preclinical biological sample sets for kinase inhibitor profiling

    2. Advanced Biochemical Assay Formulations for Diagnostic Use

    Manufacturers of clinical diagnostic kits employ Bisindolylmaleimide V in the formulation of signal modulation agents and as a specific blocker in enzyme immunoassays. Sourcing requires validated certificates of analysis for impurity profiles and consistent batch performance. Integration into final reagents involves careful dilution to avoid non-specific interactions. Trace-level additions ensure diagnostic kit reliability, helping laboratories differentiate pathological signal pathways in regulated healthcare environments.

    Industry compliance standards

    • IVD Directive 98/79/EC (EU In Vitro Diagnostic Medical Devices)
    • ISO 13485:2016 for medical device quality systems
    • CLSI guidelines for clinical laboratory materials

    Typical usage ratio

    • Standard final assay concentration between 0.1μM–5μM according to target specificity
    • Optimization based on cross-reactivity and signal-to-noise evaluations in each kit

    Downstream process integration

    • Incorporated into lyophilized reagent vials during final reagent mass production
    • Dosed during end-stage mixer cycles for multi-component assay cocktail formulation

    Final product types

    • Enzyme-linked immunosorbent assay (ELISA) diagnostic plates
    • Clinical kinase activity diagnostic reagents
    • Specialty signaling pathway analysis kits for hospital and laboratory use

    3. Specialty Cell Biology and Signal Transduction Reagent Manufacturing

    Cell culture media and molecular biology reagent producers use our material as a signaling inhibitor, controlling phosphorylation events in primary and immortalized cell lines. Strict batch documentation and high-purity specification are critical for reproducible downstream cellular response measurements. Blending typically occurs in aseptic, closed systems to prevent contamination. Titration aligns with specific cell type response, ensuring precise control over experimental outcomes in cell signaling research and functional genomics.

    Industry compliance standards

    • USP <1043> Ancillary Materials for Cell, Gene, and Tissue-Engineered Products
    • ISO 14644 for cleanroom production/process environments
    • Certificate of Analysis specifying purity and impurity thresholds

    Typical usage ratio

    • 0.5–5 μM directly in cell culture media, adjusted for cell density and sensitivity
    • Scale-up possible for bulk media (0.01–0.1% w/v), fixed after preliminary cytotoxicity testing

    Downstream process integration

    • Added into basal media or buffer pre-sterilization
    • Measured through steps monitored by in-process controls for bioreactor or multiwell plate filling

    Final product types

    • Ready-to-use kinase inhibitor culture supplements
    • Cell line-specific signal pathway inhibitor cocktails
    • High-throughput screening cell culture systems for pharmaceutical R&D

    4. Analytical Reference Standard Manufacturing

    Producers of analytical standards rely on the well-defined physical and chemical properties of Bisindolylmaleimide V for calibration curves and QC reference. The material’s purity, isomeric integrity, and stability profiles are certified through advanced analytical testing. Homogeneous mixing and strict aliquoting are required to produce stable calibration standards that can sustain transport and long-term storage in the analytical chemistry supply chain. Full traceability from raw material logistics through accredited test methods underpins lot-to-lot consistency demanded by major analytical labs.

    Industry compliance standards

    • ISO/IEC 17025 for laboratory reference material production
    • USP and Ph. Eur. standards for chemical reference substances where applicable
    • ISO Guide 34 for reference material producers

    Typical usage ratio

    • Preparation as 1 mg/mL–10 mg/mL stock solution for instrument calibration
    • Working solution range dictated by target analyte quantitation method, typically 0.1–100 μg/mL

    Downstream process integration

    • Diluted and aliquoted during final standard vialing in accredited lab environments
    • Integrated into proficiency testing panel assembly or instrument validation kits

    Final product types

    • Certified reference materials for kinase inhibitor class compounds
    • Instrument calibration standards for HPLC, LC-MS, and plate reader systems
    • Quality control validation kits for academic and industrial analytical laboratories
    Free Quote

    Competitive Bisindolylmaleimide V prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance