Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

Acetone-D6

    • Product Name Acetone-D6
    • Alias ACETONE-D6
    • Einecs 203-852-3
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    838742

    Cas Number 666-52-4
    Molecular Formula C3D6O
    Molecular Weight 64.12 g/mol
    Appearance Colorless liquid
    Boiling Point 55.8 °C
    Melting Point -94.7 °C
    Density 0.872 g/mL at 25 °C
    Purity ≥ 99 atom % D
    Refractive Index 1.357 at 20 °C
    Synonyms Deuterated acetone, (CD3)2CO
    Solubility In Water Miscible
    Smiles CC(=O)C with all H replaced by D

    As an accredited Acetone-D6 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Acetone-D6 is supplied in a 100 mL amber glass bottle with a secure screw cap and tamper-evident seal.
    Shipping Acetone-D6 is shipped in tightly sealed containers to prevent moisture absorption and evaporation. It is classified as a flammable liquid and must be transported according to relevant regulations, including appropriate hazard labeling and documentation. Typically, it is packaged in approved glass bottles or metal cans, cushioned to avoid breakage during transit.
    Storage Acetone-D6 should be stored tightly closed in a cool, dry, and well-ventilated area away from sources of ignition, heat, and incompatible materials such as strong oxidizers. Protect from moisture and direct sunlight. Use only in chemical fume hoods and ground all containers. Store in tightly sealed amber bottles to prevent evaporation and contamination. Keep out of reach of unauthorized personnel.
    Application of Acetone-D6

    Applications of Acetone-D6 in Industrial Manufacturing

    As an experienced manufacturer specializing in deuterated solvents, we formulate and supply Acetone-D6 with high isotopic purity for critical analytical and pharmaceutical applications. Below, we highlight key industrial sectors actively using Acetone-D6, with a focus on technical standards, application rates, integration in established workflows, and end products supported by our clients worldwide.

    1. NMR Spectroscopy Solvent Production

    Analytical reagent manufacturers rely on Acetone-D6 as a deuterated solvent for high-resolution proton and carbon NMR analysis. The solvent’s deuterium enrichment minimizes background hydrogen signal, supporting research, QC, and release testing in pharmaceutical, chemical, and research laboratories operating under strict quality systems. Formulators must adjust usage based on required sample sensitivity, isotopic enrichment, and compatibility with target analytes. Industrial-scale manufacturing integrates Acetone-D6 into dedicated solvent blending and bottling lines under controlled atmospheres to preserve purity and prevent isotopic dilution.

    Industry compliance standards

    • ISO 17034 (Reference Material Producer Accreditation)
    • ISO/IEC 17025 (Testing and Calibration Laboratory Accreditation)
    • Ph. Eur., USP, and JP guidelines for NMR solvents (analytical grade)
    • ICH Q7 (GMP for Active Pharmaceutical Ingredients, analytical support materials)

    Typical usage ratio

    • 90%–100% v/v for deuterated solvent composition; volume adjusted per specific NMR tube loading and sample mass

    Downstream process integration

    • Enters solvent formulation and purification process following distillation and isotopic assay, proceeds to direct bottle filling in cleanroom environments

    Final product types

    • Deuterated NMR solvents in ampoules, screw-cap vials, sealed bottles for laboratory use
    • Ready-to-use NMR sample preparation kits

    2. Pharmaceutical Impurity Testing and Method Development

    Pharma R&D and QC laboratories use Acetone-D6 as a matrix for characterizing low-level impurities, process-related residuals, and active pharmaceutical ingredient (API) confirmation by NMR. The chemical’s isotopic profile ensures minimal hydrogen exchange, enhancing data reliability for drug registration and regulatory submissions. Formulation scientists select solvent volumes to optimize signal/noise and accommodate sample solubility, while keeping to validation requirements under GMP or GLP. Integration occurs during method development, impurity profiling, and, in some cases, release and stability testing operations.

    Industry compliance standards

    • ICH Q3A/B (Impurities in New Drug Substances/Products)
    • US FDA 21 CFR Part 211 (Current Good Manufacturing Practice for Finished Pharmaceuticals)
    • EP/USP/JP monographs for analytical reagents
    • GLP (Good Laboratory Practice) regulations

    Typical usage ratio

    • Solvent use generally at 0.5–1.0 mL per NMR sample, adapted to substance concentration and tube geometry

    Downstream process integration

    • Dispensed during analytical method validation, reference standard qualification, and batch-release impurity analysis by NMR

    Final product types

    • NMR-tested API reference standards with regulatory supporting data
    • Regulatory submission files with validated impurity spectra

    3. Stable Isotope Labeled Trace Analytics

    Producers of calibration standards and certified reference materials incorporate Acetone-D6 as an isotopically labeled internal standard in environmental, pharmaceutical, and toxicological trace analysis. The labeled compound enables accurate quantification by correcting for extraction or instrument variance, meeting the strict documentation and traceability needs of regulated testing labs. Dosing is set relative to analyte expectations and detection requirements. Acetone-D6 is introduced early in analytical sample preparation, prior to extraction or chromatographic separation, and co-detected by NMR or mass spectrometry as part of the calibration/control matrix.

    Industry compliance standards

    • ISO 17034/ISO Guide 34 (Reference Material Certification)
    • ISO 17025 (Testing Laboratories, quality control of reference materials)
    • EPA SW-846, OECD, and REACH guidelines for trace analysis
    • USP General Chapter <621> (Chromatography)

    Typical usage ratio

    • Spiked at 10–1000 μg/L (ppb–ppm), calculated against expected analyte concentration, with adjustment for method sensitivity

    Downstream process integration

    • Added during standard solution or calibration mix preparation; incorporated into QC sample manufacturing before distribution to analytical labs

    Final product types

    • Certified reference standards for regulatory laboratory testing
    • Internal standards for LC-MS, GC-MS, and NMR-based quantitative analysis kits

    4. Deuterium Isotope Exchange Research in Organic Synthesis

    Custom synthesis providers and academic research groups use Acetone-D6 as a deuterium donor in mechanistic, kinetic, and pathway elucidation studies. The strong C-D bonds inform site-specific labeling and allow tracking by NMR or mass spec. Additive levels and solvent concentrations are chosen based on substrate type, desired degree of labeling, and reaction compatibility. The material is typically introduced during initial reaction setup or as a quenching agent in isotope exchange protocols routed through glass-lined or inert atmosphere reactors. Downstream QC verifies labeling position and isotopic abundance in purified end-products for use in advanced studies.

    Industry compliance standards

    • ISO 9001 (Synthesis quality management systems)
    • GMP requirements for labeled research substances (if intended for pharma support)
    • Project-specific research protocols and institutional review guidelines
    • OECD GLP where applicable to reference material synthesis

    Typical usage ratio

    • Solvent or reagent concentration at 50–100 vol% depending on reaction type; volume scaled to substrate mass and labeling target

    Downstream process integration

    • Charged directly to the reactor during isotope exchange or mechanistic study set-up; isolated by subsequent purification (e.g., distillation, crystallization)

    Final product types

    • Deuterium-labeled organic molecules for mechanistic probes
    • Site-selectively labeled intermediates for pharmaceutical, chemical, or environmental tracer studies
    Free Quote

    Competitive Acetone-D6 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance