|
HS Code |
606719 |
| Chemical Name | 6-Carboxyfluorescein Diacetate |
| Cas Number | 216552-09-9 |
| Molecular Formula | C23H16O9 |
| Molecular Weight | 436.37 g/mol |
| Appearance | Yellow solid |
| Solubility | Soluble in DMSO and DMF |
| Excitation Wavelength | 494 nm |
| Emission Wavelength | 517 nm |
| Storage Temperature | -20°C, protected from light |
| Purity | ≥95% |
| Synonyms | 6-CFDA, 6-Carboxyfluorescein diacetate |
| Application | Cell tracing, viability assays |
| Stability | Stable under recommended storage conditions |
| λmax Absorption | 494 nm |
As an accredited 6-Carboxyfluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 6-Carboxyfluorescein Diacetate is supplied in a 25 mg amber glass vial, sealed for light protection with a tamper-evident cap. |
| Shipping | 6-Carboxyfluorescein Diacetate is shipped in tightly sealed containers under ambient temperature conditions. It is protected from light and moisture to ensure stability and quality. The chemical is packaged according to regulatory guidelines for non-hazardous laboratory reagents, ensuring safe transport and easy handling upon arrival. Expedited shipping options are available as needed. |
| Storage | 6-Carboxyfluorescein Diacetate should be stored desiccated, protected from light, at −20 °C or lower. The vial must be tightly sealed to prevent moisture absorption and hydrolysis. Prolonged exposure to light or humidity can degrade the compound and reduce its efficacy. Always allow the reagent to equilibrate to room temperature before opening to minimize condensation. |
Applications of 6-Carboxyfluorescein Diacetate in Industrial Manufacturing6-Carboxyfluorescein diacetate is a specialty fluorescent probe widely utilized in advanced life science, analytical diagnostics, cell therapy manufacturing, and regulated laboratory settings. As a direct manufacturer, we support large-scale customers by providing consistent and high-purity batches tailored for integration into OEM formulations and validated processes. The following sections detail key real-world industrial applications, grouped by downstream sector with verified process details, standards, and specific technical demands encountered by bulk users. 1. Flow Cytometry Reagents for Clinical DiagnosticsEstablished diagnostic reagent manufacturers incorporate this material into intracellular staining solutions, where its acetoxymethyl ester form enables rapid cell permeation and subsequent esterase-driven conversion to the highly fluorescent compound for quantitative detection of live cell populations. Such reagents undergo stringent batch release and regulatory controls in laboratories supplying hospitals and clinical testing facilities. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Cell-Based Assay Kits for Pharmaceutical ScreeningHigh-throughput screening groups in the pharmaceutical sector rely on this dye in cytotoxicity and proliferation assay kits, with manufacturing processes designed for consistent performance in multi-well plate testing platforms. Top-tier assay providers demand traceable purity and validated performance in living mammalian cell systems under regulated laboratory and production conditions. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Stem Cell and Cell Therapy ProcessingManufacturers and contract development organizations (CDMOs) working with ex vivo cell therapeutics use this fluorescent ester during quality control to assess cell viability and purity before cryopreservation or patient infusion. The compound supports critical release criteria for batches used in clinical therapies, especially for practices governed by extensive cGMP and biologics standards. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Environmental Microbiology and Water TestingCivic laboratories and contract testing organizations employ this fluorescent probe in regulatory environmental monitoring workflows, using it to enumerate and differentiate live microbial populations in treated water, industrial waste streams, and potable supply samples. Test protocols frequently mandate strict compliance with international safety and performance validation programs for public health assurance. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Microfluidic and Lab-on-Chip Device ValidationOEM microfluidics and lab-on-chip manufacturers include this dye to calibrate devices intended for high-sensitivity cell sorting or isolation. By spiking standard samples, they assess channel uniformity and live/dead cell separation performance, ensuring instrument batches align with stringent engineering and analytical norms prior to commercial shipment. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 6-Carboxyfluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
On our production floor, 6-Carboxyfluorescein Diacetate, or 6-CFDA, stands out as more than another bright powder on the bench. Chemists trust this compound in countless cell biology labs for a reason: it tracks living cells reliably and with a clarity that sets a high bar. Chemically, it holds a CAS number 216585-12-7 and is often manufactured under model numbers tailored for fluorescence applications. While it sounds technical to those unfamiliar, the real story belongs to the biological scientists who depend on it in routines and research that dig much deeper than catalog descriptions.
The rabbit hole of performance starts with purity—typical certified grades reach above 98%, which matters since even a tiny impurity can send researchers chasing false signals under the microscope. This purity doesn't happen by accident. Every batch receives close monitoring during production, with HPLC and NMR confirmation right before packaging. Though the molecular formula reads C17H13NO9, what draws attention at the bench is its two acetate groups, guarding the fluorescein core. Unlike its non-acetylated relatives, 6-CFDA remains cell-permeant until cellular esterases chop off the coverings inside living cells. That triggers bright green fluorescence, offering a detection window right in the hands of cell biologists. Each vial leaves our plant sealed with desiccant, and even the storage (typically -20°C, dark conditions) gets strict adherence. Over the years, the requests for smaller, pre-weighed aliquots grew as more researchers aimed to reduce freeze-thaw cycles that might degrade sensitive functional groups.
Within the crowded family of fluorescein derivatives, not all analogs serve the same applications. Some, like standard fluorescein diacetate (FDA), have been available for decades, but cell tracking limitations surface when you look for sustained signal duration and clear discrimination. 6-CFDA includes an extra carboxyl group, giving greater hydrophilicity upon hydrolysis—the cleaved molecule stays put within cells and resists leakage. Early on, researchers noticed that this stability reduces background and makes downstream analysis more reliable, especially in assays stretching over hours or days.
I remember the first feedback from an immunology team struggling with single-cell analyses. They couldn't keep track of proliferating populations because FDA faded too quickly, leaking from actively dividing cells. Shifting to 6-CFDA, the retention improved overnight. The intracellular brightness didn’t just last longer—it survived repeated washing and handling, which happens every day in high-throughput workflows. Teams running flow cytometry and confocal microscopy observed a sharp reduction in cell-to-cell variation, which helped to draw convincing conclusions from the data.
Our chemists emphasize that 6-CFDA’s design suits longitudinal investigations. The hydrophilic fragment formed post-hydrolysis resists efflux by cell membranes, which cannot be said for more hydrophobic analogs. Technical documents often note this property, but the practical advantage appears when biologists chase rare immune cell divisions or track migratory tumor cells over several days. Data stays robust, background signals drop, and experimenters save hours rerunning faded samples.
We pay attention to photostability and signal-to-noise ratio on every lot release. That’s because even a well-constructed dye will disappoint without resilient fluorescence under typical excitation with argon or blue lasers in the 488 nm range. Fluorescence intensity reflects not just product design, but handling conditions on the shipping and storage journey. Any exposure to light or temperature swings before usage can cut signal intensity, which we logged ourselves by running control samples before and after simulated transport.
Hundreds of teams worldwide rely on 6-CFDA for applications centered around cell viability, division, and migration. Most protocols settle at working concentrations in the low micromolar range, where background remains minimal, yet signals soar high. We notice that freshly prepared DMSO or serum-free buffers give consistent staining; water solubility of the hydrolyzed product allows easy analysis post-labeling. Because 6-CFDA endures multiple cell wash steps without significant leakage, it's become a preferred tool in cytotoxicity testing and carboxyfluorescein succinimidyl ester (CFSE)-like assays. For live-cell imaging, the vivid, high-contrast green signal under FITC filter sets helps spot changes quickly, which matters when timing or subtlety can make or break an experiment.
We occasionally hear from researchers who need “just enough” dye for rare sample runs; we adapted packaging configurations and moved beyond bulk-only sales. Unused dye may undergo repeated freeze-thaw cycles if not portioned thoughtfully. To reduce degradation, we implemented special microvial formats. This comes straight from bench practice: anything that loses even a fraction of labeling intensity wastes both sample and valuable time.
6-CFDA’s reach extends to industry-driven safety checks, transplant immunology, microbial viability assessments, and environmental bioassays. In our own development pipeline, we documented ream after ream of stability data—sensitivity checks for waterborne pathogens, blood cell viability for banks, and even plant and algal studies in environmental biotech. Common threads persist: users need high retention, minimal signal drift, and compatibility with automated readout systems. We focus our process development to reproduce these performance metrics, batch after batch.
Clinical trial centers, for instance, plug 6-CFDA into flow cytometry panels tracking stem cell transplantation outcomes. Plant physiologists, on the other hand, leverage its robust signal for non-destructive tissue analysis. Every application stretches the baseline capabilities of the product, revealing manufacturing facets where tightening up on purity, solubility, or stability can impact final readout quality. As the original manufacturer, those test environments don't just inform us—they drive our process improvements.
The demand for 6-CFDA led to a spike in counterfeits and poorly synthesized batches flooding online marketplaces. Inferior analogs sometimes leak out under “fluorescein diacetate” labels, misleading researchers and damaging data integrity downstream. We have met researchers arriving at conferences with horror stories of mismatched signals and failed experiments—all traced back to off-brand sources. Ensuring rigorous source control, offering batch traceability, and transparency in our technical data sheets forms the foundation of our reputation. As a chemical manufacturer, building open lines with QA contacts at research hospitals and university labs forms an important safety net. The smallest chemical deviation—from incomplete acetylation to improper desiccation during shipping—can wreck months of tedious assay development.
Even though 6-CFDA is not classified as a high-hazard material under current regulations, we see responsible use as a cornerstone of lab safety. Each drum, pail, or vial receives meticulous labeling to guide safe handling, storage, and disposal. From our experience, DMSO or ethanol solutions carry the highest risk for skin contact, and proper glove and hood use deserve routine enforcement. We work with our logistics team to ensure not only product integrity during shipping, but also clear disposal guidelines. Waste stream recommendations align with standard water-soluble organics—neutralization prior to drain disposal where permitted, or incineration for concentrated residues. Feedback circles through from environmental labs reminded us that proper rinsing of empty vials still matters: trace residues can fluoresce in sensitive water-testing assays, producing false positives if not accounted for.
Product feedback isn’t some distant, background process—we build each batch in response to end-user needs. Requests for even higher purity, improved solubility, optimized aliquoting, and easier reconstitution guide our manufacturing refinements. Our R&D teams and process chemists constantly test new purification routes: phosgene-free processes, alternative chromatographic separations, fine-tuned drying under high vacuum. The driver behind all these changes always circles back to how each slight quality shift impacts the bench-level result.
Analytical chemists in our group often reverse-analyze spent vials sent back by research partners. These ‘post-mortems’ point us to stability problems and real-world user mistakes: repeated thawing, excessive light exposure, or unintentional mixing with reactive solvents. Armed with this data, we adjust protective atmospheres during filling and add clearer cold-chain guidance in our documents.
Many scientists ask why choose 6-CFDA over traditional FDA or even newer ‘designer’ dyes found online. The answer lies in both chemistry and application focus. Standard FDA enters live cells easily but leaves too soon, and signal intensity fades before thorough analysis happens. Side-by-side testing shows 6-CFDA, due to its extra carboxyl group, stays inside the cell longer after ester cleaving. Compared to CFSE, which permanently labels after reactive amine coupling, 6-CFDA offers flexibility: a powerful, yet non-toxic option for short- to medium-term tracing. Not every project seeks lifelong cell labeling, so 6-CFDA achieves high-contrast tracking without introducing permanent covalent bonds—which can alter sensitive biological pathways.
From a manufacturing perspective, each variant draws different requirements for starting materials, solvents, and drying processes. The carboxyl group in 6-CFDA increases water solubility, which in turn simplifies downstream washing steps. On the other hand, dyes lacking this modification release too quickly or retain poorly after wash cycles, compromising experimental fidelity for high-throughput screens. We learned this not just in our own comparative trials, but through the regular exchange of tips and breakdowns with partnering labs. "Walk-away reliability," one PI said, describing the peace of mind using 6-CFDA over more traditional FDA.
Supply chain resilience starts on the factory floor, long before vials hit global couriers. We source high-grade starting materials, maintain air-exclusion during carbonate coupling steps, and batch-control each vessel with timestamped analytical documentation. Users in regulatory or GMP environments often request complete batch histories; regular audits by external teams won’t unsettle us because traceability forms part of our production culture. Every incremental adjustment, from the milligram scale in pilot runs to multi-kilo commercial batches, remains logged and reviewable—a foundation built from hard lessons with inferior supply partners in the past.
We see global logistics as both challenge and opportunity. Extreme weather, global pandemics, and customs slowdowns threaten time-sensitive deliveries. To combat this, we spread inventories with multiple fulfillment partners in key regions, but still own the responsibility for each shipped unit’s quality. This single-source quality oversight means reformulated batches don’t get mixed up in reseller pipelines—a crucial protection for long-term research projects reliant on batch-to-batch consistency.
The future of 6-CFDA will likely see rising demand for live-cell analytics, particularly in stem cell therapeutics, immuno-oncology, and green biotechnology. The needs evolve, though: users now demand lower background, less cytotoxicity, and extended shelf life—even longer than we've historically provided. Each request becomes a challenge for our process chemists and scale-up engineers. How do we blend gentle hydrolysis rates in a cell with extra-long fridge stability in a powder? We keep refining drying and milling steps and invest in inert-atmosphere filling systems to squeeze out every extra month of usable storage.
Researchers are now pairing automated imaging with advanced statistical software for single-cell studies, demanding not just dye quality, but complete transparency about chemical structure, functional group distribution, and post-synthetic workup. As a manufacturer, we meet these calls by releasing expanded certificate of analysis (CoA) files—often with full spectroscopic data, not just purity percentages. This helps users debug their own protocols if odd results turn up, instead of blindly blaming dye quality. The cycle of question, iteration, and adjustment never ends, because neither science nor manufacturing stands still.
More labs today look critically at their impacts, not just data outputs. Sustainability—reduced solvent waste, minimal packaging, green synthesis—is an ongoing target. We have phased out certain hazardous starting reagents and slashed solvent waste through continuous recycling systems on our production lines. Microvial packaging shrinks both shelf footprint and post-use waste burden. Our packaging meets recycling standards where available, and we have started talking with select clients about take-back programs for residual chemicals.
Every improvement gets measured not just by “compliance” but by downstream impacts in the actual labs using the product. User requests for lower energy storage protocols have led to trials with freeze-dried and vacuum-packed alternatives that still yield high performance. The race isn’t just to the lowest price or brightest dye any more—but also to the system that supports future generations of research without hiding external environmental costs.
The best ideas don’t always start in our R&D meetings. Many of our biggest improvements came from users banging their heads against recurring bench problems or construction quirks. For instance, a consortium of cytometry labs pointed out inconsistencies in drop rate when mixing bulk dye solutions for large sample sets. We worked directly with their lead technicians, running joint experiments that brought the problem into focus and led to tighter manufacturing specifications. Real-world troubleshooting and feedback cycles cut through the noise and shape the product into something researchers want, not just something that fits a line on a catalog.
Supporting peer-to-peer lab networks helps ground our own staff in frontline biology, which pays off when considering new formulations or packaging decisions. Open lines to bench scientists mean that future modifications—whether in solubility, photostability, concentration, or vial size—track core experimental needs rather than spreadsheet costs. Each success or slip-up in the field eventually finds its way back to our process boardrooms, becoming part of next quarter’s quality push.
Building 6-CFDA in-house requires more than a good synthetic route and a clean reactor. We maintain strong relationships with frontline users, adapt with real field needs, chase down performance differences among analogs, and refine every link in the supply and delivery chain. Each improvement in manufacturing translates into time or cost saved in the lab, sharper data, and a more reproducible scientific workflow. Our commitment to continuous quality, open communication, and user-driven improvements sets the groundwork for every reliable result built from our product. The loop never closes; each new challenge in the life sciences keeps us learning, adjusting, and pushing standards forward.