Chengjiang, Yuxi, Yunnan, China sales1@sinochem-nanjing.com
Follow us:

5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt

    • Product Name 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt
    • Alias X-Gluc
    • Mininmum Order 1 g
    • Factory Site Chengjiang, Yuxi, Yunnan, China
    • Price Inquiry sales1@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    236032

    Product Name 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt
    Abbreviation X-Gluc
    Cas Number 18656-96-7
    Molecular Formula C20H23BrClN2O8
    Molecular Weight 531.76 g/mol
    Appearance Powder
    Color White to off-white
    Solubility Soluble in water
    Storage Temperature 2-8°C
    Application Substrate for β-glucuronidase assays
    Synonyms X-GlcA Cyclohexylammonium Salt
    Sensitivity Light sensitive

    As an accredited 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The chemical is supplied in a 100 mg amber glass vial, tightly sealed, with tamper-evident cap and labeled for laboratory use.
    Shipping 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt is shipped at ambient temperature in a tightly sealed container. The product is protected from moisture and light, and is labeled according to safety and chemical regulations. Shipping includes appropriate documentation, and expedited delivery is recommended to preserve quality and ensure integrity of the chemical.
    Storage 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt should be stored at -20°C in a tightly sealed container, protected from light and moisture. Keep the chemical in a dry, well-ventilated area, away from incompatible substances. Allow the reagent to equilibrate to room temperature before opening to avoid condensation. Proper storage maintains its stability and prevents degradation.
    Application of 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt

    Applications of 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt in Industrial Manufacturing



    As a direct manufacturer of 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt, we focus on supporting downstream sectors that require high specificity and sensitivity for the detection and quantification of β-glucuronidase activity. Our production complies with international quality systems, and we tailor our processes to the requirements of our industrial clients across the following real-world applications.



    1. In Vitro Diagnostic Test Manufacturing



    Diagnostic reagent companies depend on this substrate to develop chromogenic media for rapid detection of Escherichia coli in clinical and food industry samples. Our product offers distinct color development, ensuring easy visualization and accurate colony differentiation during microbiological analysis. Formulators select the substrate concentration based on intended sensitivity, sample type, and matrix complexity, and maintain strict adherence to pharmacopoeial and in vitro diagnostic (IVD) standards.


    Industry compliance standards



    • European Pharmacopoeia (Ph. Eur.) reagent quality requirements

    • ISO 13485 Medical Devices Quality Management

    • IVDR (EU) 2017/746 for clinical diagnostic reagents

    • CLSI M50 guidelines for performance standards in chromogenic media


    Typical usage ratio



    • Commonly 50–200 mg/L in finished agar or broth medium, optimized for sample load and detection limits

    • Higher concentrations may be required for complex matrices; labs conduct pre-validation to finalize dosage


    Downstream process integration



    • Blended into selective agar or chromogenic broth during media compounding before sterilization (at 45–55 °C)

    • Stability ensured by adjusting pH and controlling autoclaving times

    • Integrated with ancillary selectivity agents and growth supplements to form complete media kits


    Final product types



    • Pre-poured chromogenic agar plates for pathogen screening

    • Dehydrated chromogenic media powders for on-site preparation

    • Ready-to-use liquid broth kits for environmental and clinical diagnostics



    2. Food and Beverage Microbial Testing Panel Production



    Global food safety laboratories and test kit manufacturers use this substrate in detection panels targeting coliforms and E. coli in processed foods, bottled water, and raw ingredients. The product's high signal-to-noise ratio permits clear colony identification, even in high-background matrices, while satisfying international food pathogen monitoring requirements.


    Industry compliance standards



    • ISO 4832 and ISO 16649-2 for enumeration of coliforms and E. coli

    • US FDA BAM (Bacteriological Analytical Manual) chromogenic test methods

    • GB 4789.38-2023 (China National Food Safety Standard)


    Typical usage ratio



    • Standard medium formulations: 100–180 mg/L, adjusted for product matrix and target detection threshold

    • Modifications in multi-enzyme substrates require proportionate adjustments to preserve selectivity


    Downstream process integration



    • Dispersed into powder blends for chromogenic detection plates used in routine QC labs

    • Added to partitioned wells or dipstick formats during test kit assembly

    • Protected in foil-pouch single-use sachets with inert carrier for field testing kits


    Final product types



    • Chromogenic test strips for on-site food factory screening

    • Premixed industrial coliform detection plates

    • Automated water and beverage testing panels for high-throughput analysis



    3. Environmental Monitoring & Water Quality Test Production



    Leading environmental monitoring firms rely on this substrate to indicate contamination by fecal bacteria in municipal water, recreational surface water, and effluent discharge. Shifts in color profile enable rapid field-based detection, supporting compliance with regulatory discharge limits and public health surveillance. Downstream use aligns with international environmental testing protocols and routine waterworks quality control procedures.


    Industry compliance standards



    • ISO 9308-1 for the enumeration of E. coli and coliforms in water

    • US EPA 1604 (Colilert® medium equivalency)

    • EN ISO 9308-2 for water testing laboratories in Europe


    Typical usage ratio



    • Solution or tablet forms: 80–150 mg/L in final volume, titrated to sensitivity requirements of source water

    • Low-background environments may allow use at the lower range; turbid water samples may require upper range


    Downstream process integration



    • Incorporated into self-dissolving tablets for on-site field testing kits assembled on automated filling lines

    • Blended into ready-to-use liquid test mediums for laboratory or on-site use

    • Packaged in multi-unit sealed vials with desiccant for extended shelf stability


    Final product types



    • Portable water testing sets for field inspections by environmental agencies

    • Commercial water treatment plant test kits used for compliance monitoring

    • Consumable reagents for environmental lab automation analyzers



    4. Biotechnology Custom Substrate Synthesis



    Biopharmaceutical research organizations and custom substrate suppliers integrate this compound as a structural core to develop novel chromogenic or fluorogenic markers used in enzyme-probe screening, enzyme engineering, and in process analytics for genetic and microbial engineering projects. Quality assurance and reproducibility remain critical, with strict conformance to biotechnological synthesis and laboratory use standards.


    Industry compliance standards



    • OECD Guidelines for the Testing of Chemicals, Section 3 (Biodegradation and Transformation)

    • ISO 9001:2015 for research and intermediate material production

    • Internal SOPs governed by GLP (Good Laboratory Practices) for lot traceability


    Typical usage ratio



    • Routinely 0.1–0.5 mmol/L for small-scale substrate libraries or probe development

    • For pilot-scale synthesis, ratio adjusted to achieve desired molar excess or specific chromophore intensity


    Downstream process integration



    • Reacted as a building block in high-purity probe synthesis on automated peptide or oligonucleotide synthesizers

    • Used in conjugation reactions for novel test reagent production

    • Stored under nitrogen and handled in light-protected vessels to maintain purity prior to custom application blending


    Final product types



    • Chromogenic enzyme substrates for high-content screening

    • Custom fluorogenic markers for gene editing assays

    • Specialty analytical reagents for bioengineering process monitoring

    Free Quote

    Competitive 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt: Insight from the Manufacturer

    An Introduction to the Product We Craft Every Day

    Producing 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt isn’t just about following a recipe. Every kilogram comes from careful process control, a tight selection of raw materials, and in-depth understanding of indoxyl-based chromogenic substrates. The chemistry behind it rewards consistency and attention to detail. As a manufacturer, we aim for each batch to deliver the same clear, reliable results that microbiologists and lab technicians expect, because inaccurate results cost more than just inconvenience—they set research and routine diagnostics back.

    In our facility, synthesis starts with thorough purification of precursors, since stray impurities at any step can ruin yield and quality. We invest in quality controls, monitoring for even minor deviations from expected color and solubility. Over the years, we’ve noticed the substrate’s unique structure—especially the position of bromine and chlorine atoms—plays a critical role in enzyme specificity, directly affecting how labs detect and differentiate β-glucuronidase activity. Blending cyclohexylammonium as the counterion improves the salt’s aqueous solubility over sodium or potassium forms. This supports more consistent reagent preparation, which suits high-throughput environments and reduces the risk of microplate variability.

    Specifications and Our Manufacturing Approach

    With this product, laboratories and kit developers often have strict application protocols and may request different mesh sizes or morphologies, depending on whether the substrate needs to dissolve rapidly or stay suspended longer during incubation. We offer a standard granule size range defined by years of feedback from culture media manufacturers and academic partners. This is practical for direct weighing without pre-grinding or sieving—a detail that reduces technician workload. While we keep moisture content controlled, guarding against degradation, we also focus on avoiding dustiness, since fine particles rarely flow or dissolve predictably.

    Most of our production runs use high-purity starting indoles and glycosides sourced from trusted upstream chemical suppliers with established analytical track records. At the end of each batch, we run several tests—not just simple melting point checks, but HPLC, spectrophotometry, and, for special orders, mass spectrometry—to confirm the absence of potentially interfering side-products. We know lot-to-lot consistency is vital, especially when customers standardize protocols across multiple labs or regions. The cyclohexylammonium salt is hygroscopic and best handled with dry-room conditions during bottling and packaging, so our production spaces are equipped to keep water activity low. This reduces lumping and assures longer shelf life in storage conditions commonly found in chemical storerooms.

    Application: How End Users Experience the Product

    In practice, customers use our 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt as a standard detection substrate in chromogenic media for microbial screening. It is most recognized for colony differentiation on plate-based culture methods, especially when identifying Escherichia coli and other β-glucuronidase-positive organisms within mixed samples. The clear blue color formed after enzymatic cleavage stands out even in complex matrices. Once added into a medium, lab staff no longer need to rely on off-white or hard-to-see color changes that can be too subtle in crowded plates. This kind of clear endpoint enables high-throughput screening and unambiguous results—laboratories save time by reducing the need for double-checking or confirmatory tests.

    Several partners in water testing tell us that, during routine compliance monitoring, this substrate has reduced operator errors. Fewer ambiguous color reactions help maintain regulatory reporting standards and avoid repeat analysis, so laboratories can stay ahead of audit demands. We learned that in food and beverage safety labs, substrate stability in dry-blend media ensures plates have a longer working life. That means restocking less frequently and holding the line against unnecessary wastage.

    Some biotechnologists integrate the compound into custom biosensor arrays, using the distinct blue precipitate as a sharp optical signal in both endpoint and real-time systems. These applications push the substrate out of routine microbiology into new diagnostic fields, often in research universities and medical device startups. We collaborate with some of these partners to tweak granule size or packaging to match their dispensing machines or cartridge-fill systems—details shaped by hands-on experience rather than only theoretical requirements.

    Differences from Similar Substrates and Variants

    Our product does not get confused with indoxyl-based substrates commonly found as sodium or potassium salts. Many off-the-shelf alternatives lack the cyclohexylammonium counterion, and this makes a real difference in bench performance, mostly around solubility and background clarity. Unlike less soluble forms that sometimes leave stubborn residues at the bottom of flasks or petri dishes, our salt dissolves quickly in standard solvent volumes, especially in buffered aqueous solutions. As someone making these compounds, I’ve seen firsthand how poor dissolution can block filtration setups or cause plates to lose transparency, delaying whole testing batches.

    Other synthetic variants may use 5-bromo-3-indolyl or 6-chloro-3-indolyl structures alone, but both lack the double-substituted specificity for certain microbial enzymes. This product’s affinity for β-glucuronidase means cleaner, more reliable endpoint color reactions—especially valuable in clinical, environmental, and food safety workflows with significant financial or safety impact. We chose this double halogenation because single-substituent analogs did not perform as well across the pH and temperature ranges found in typical media.

    We occasionally see inquiries regarding sodium salt variants, mainly due to price or supply preferences. Experience has taught us that sodium-based salts, while cheaper on paper, tend to absorb environmental moisture at a higher rate, sometimes clumping during storage or transit. Unlike the cyclohexylammonium-free versions, our salt holds together in variable humidity and does not develop the caking or yellowing we’ve encountered during long-term stock checks. That difference spells fewer complaints about undissolved material or short shelf life, issues that can snowball if undetected until a plate fails to develop.

    Some competitors push for high-purity grades at the expense of robust packaging, which often backfires if the compound is exposed to lab air or multiple dispensing cycles. We balance purity with packaging designed for real-world bench handling. That means bottles with reliable seals and light-blocking properties—details validated every time we pull historical samples from storage and test them alongside new batches. Legacy samples maintain their performance, reducing the risk of surprises during quality control retesting.

    Why the Details Matter: Real-World Lab Impact

    Precision in manufacturing isn’t just internal compliance; it translates into fewer headaches for our end users. When one lot fails, it isn’t an abstract number on a COA for us; it can force labs to repeat days of patient or environmental testing, delay product release, or put safety data at risk. By keeping synthesis and quality checks in-house, we’re closer to the source of any issue and can trace, troubleshoot, and fix it rapidly. Working alongside technical support teams, we track feedback—not just from distributors but also from scientists at government agencies, private companies, and universities.

    We have seen how minor formulation changes or undetected lot variation in the substrate can lead to false negatives or positives. This isn’t a theoretical risk—medical microbiology labs, for example, could release contaminated products, or public health labs might miss environmental outbreaks. Precision, reliability, and documentation matter most here. We’ve tuned our process over the years to cement a strong reputation with regulatory auditors as well as long-term clients.

    One story that comes to mind: a long-term customer brought a batch to us, complaining of color loss in stored media blends. Rather than blame an external factor, we pulled reference materials, retested exposed samples, adjusted desiccant levels in our packaging, and rolled out a rapid notification to everyone down the supply chain. This approach helped one water monitoring lab avoid regulatory fines by switching to the improved packs before any non-conformance reports surfaced—direct, concrete action based on knowing the product inside out.

    Supporting Results That Stand Up to Scrutiny

    Among the largest buyers of 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt are reference laboratories tied to regulatory agencies. Many conduct round-robin proficiency assessments to check comparability across many locations. Only substrates with consistent performance under those conditions maintain trust. Failing a ring test brings resupplies, audits, and lost time. By releasing batch reports, maintaining a well-documented production log, and offering real-time traceability, we allow our customers to focus on their own missions: public safety, food security, or scientific advancement.

    We believe the tight integration between our production and customer support teams helps prevent issues from snowballing. Every time a new lot comes off the line, our quality analysts review both historical and real-time data. We offer technical bulletins, troubleshooting tips, and customized application support when novel uses or unexpected results emerge. If a research group wants to adapt the compound for a novel application—such as smartphone-based biosensors, or point-of-care diagnostics—we’re able to tweak parameters to fit their requirements, because our synthesis is under control, not outsourced or generic.

    Looking Ahead: Challenges in the Field

    Chromogenic substrates once seemed like a simple, routine chemical—but with the increased scrutiny on results by regulators, labs need every edge in accuracy and reproducibility. We have seen issues with counterfeit or low-quality imports that cannot match analytical purity or dissolution rates, leading to failed batches. We combat this by marking our packaging with unique lot codes and tracking not only the finished goods but the raw material sources. Traceability down to raw component lots can make the difference when investigating unexpected performance dips.

    As more diagnostic platforms push toward automation and point-of-care, packaging and formulation need to adapt as well. Tablet, bead, or single-use formats are growing in demand; sticking to only bulk powder puts manufacturers behind the curve. Our team has started developing alternative delivery systems for high-consumption clients in automated media preparation. This requires altering some of our process controls and in-process checks to guarantee the final form performs identically to the traditional powder—even small shifts in granulation or binding agents influence how quickly media develops its color signature.

    One ongoing challenge is the growing pressure to minimize solvent waste and boost green chemistry in production. Our synthetic chemists review existing methods annually, looking for process steps where solvent recovery or reactant recycling can both drive down cost and lighten our environmental footprint. By sharing environmental data and supplying comprehensive product lifecycle information, we meet buying standards set by clients within the pharmaceutical and public health sectors.

    How Our Approach Reflects Direct Manufacturing Experience

    Unlike traders or generic repackagers, we own every step from inception to bottle. We track not just analysis but performance in media, taking pride in subtle optimizations that only become clear after years in the field. We stay involved after delivery, guiding customers from protocol development to in-process troubleshooting, and maintain strong feedback loops with regulatory auditors.

    The difference from resellers or third parties is pronounced—decisions about raw material sourcing, how to respond to global supply interruptions, and even which quality benchmarks to exceed, come directly from seeing real-life outcomes in laboratories. Customer visits to our plant often prompt new insights or adjustments, whether it’s about container size, labeling clarity, or batch-specific advice for work-up in custom assays.

    For us, 5-Bromo-6-Chloro-3-Indolyl-D-Glucuronide Cyclohexylammonium Salt isn’t just another product in a catalog—it’s a compound with decades of lessons behind each bottle. Each refinement reflects a blend of scientific rigor, technician feedback, and experience navigating supply chain bumps and changing regulatory landscapes. This commitment isn’t abstract—it lives in daily batch records, QC checks, and in every conversation with the labs that rely on our chemistry.

    Partnering for Better Outcomes

    At the end of each day, we remember these substrates support decisions about health, safety, and science—often in high-stakes or time-critical situations. Our ongoing collaborations with leading labs, regulatory agencies, and development partners help shape incremental improvements, such as one-off large-batch runs, custom sizing, or more robust packaging. Practical issues spotted in the lab—with granulation, solubility, or packaging—get tracked and addressed without looping through layers of distribution or translation.

    For those using the substrate beyond conventional applications—maybe in new instrumentation or for screening non-standard organisms—our doors are open to discuss real-world challenges. We put small pilot batches in the hands of innovators, then circle back with adjustments based on returned results. Being close to manufacture and field use, we reflect on each outcome and factor that back into process tweaks. That’s manufacturing driven not just by order books, but by a real partnership with science and safety at its core.