Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing sales7@sinochem-nanjing.com 3389378665@qq.com
Follow us:

4-Nitrophenyl-Beta-D-Glucuronide

    • Product Name 4-Nitrophenyl-Beta-D-Glucuronide
    • Alias PNPG
    • Einecs 225-080-4
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry sales7@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    990212

    Product Name 4-Nitrophenyl-Beta-D-Glucuronide
    Cas Number 3767-28-0
    Molecular Formula C12H13NO10
    Molecular Weight 347.23
    Appearance White to off-white powder
    Melting Point 195-197°C
    Solubility Soluble in water
    Storage Temperature 2-8°C
    Purity ≥98%
    Synonyms p-Nitrophenyl β-D-glucuronide
    Chemical Class Glycoside
    Application Substrate for β-glucuronidase assays

    As an accredited 4-Nitrophenyl-Beta-D-Glucuronide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The packaging is a sealed amber glass bottle containing 1 gram of 4-Nitrophenyl-Beta-D-Glucuronide, clearly labeled with hazard information.
    Shipping 4-Nitrophenyl-Beta-D-Glucuronide is shipped in secure, leak-proof packaging suitable for chemicals. It is typically transported at ambient temperature, unless otherwise specified by the manufacturer. The product label includes identification and safety information, and all shipments comply with relevant regulations for laboratory chemicals to ensure safe delivery.
    Storage 4-Nitrophenyl-Beta-D-Glucuronide should be stored in a cool, dry, and well-ventilated place, tightly sealed in its original container. Protect it from light, moisture, and sources of ignition. Ideally, it should be kept at 2–8°C (refrigerated) and away from incompatible substances such as strong oxidizers or acids. Proper labeling and handling under laboratory safety guidelines are essential.
    Application of 4-Nitrophenyl-Beta-D-Glucuronide

    Applications of 4-Nitrophenyl-Beta-D-Glucuronide in Industrial Manufacturing

    4-Nitrophenyl-Beta-D-Glucuronide is a specialty glucuronide substrate widely utilized in industrial and laboratory-scale enzymatic detection and biochemical testing. Below we detail major industrial application scenarios, highlighting specific compliance standards, recommended processing ratios, technical integration points, and typical end products.

    1. Microbiological Detection Media Formulation

    Industrial and contract microbiology labs employ this substrate as a chromogenic reagent for the selective identification of Escherichia coli through beta-glucuronidase activity. In manufacturing processes, formulators add it to culture media powders or prepared plates to enable direct visual differentiation based on chromophore release upon enzymatic hydrolysis. Consistent substrate quality is essential for producing media products that meet regulatory criteria for food, water, and pharmaceutical testing sectors.

    Industry compliance standards

    • ISO 9308-1 (Water quality – Detection and enumeration of Escherichia coli and coliform bacteria)
    • FDA BAM (Bacteriological Analytical Manual) requirements for selective media
    • European Pharmacopoeia 2.6.13 (Microbiological examination of non-sterile products)
    • ISO 11133 (Preparation, production, storage and performance testing of culture media)

    Typical usage ratio

    • Concentration in final culture media: 50–75 mg per liter depending on matrix and customer test protocol
    • Ratio adjusted for plate vs. broth format to maintain detection sensitivity and minimize background

    Downstream process integration

    • Added during dry blend or liquid concentrate preparation stages of media manufacturing
    • Introduced prior to sterilization; stability ensures performance post-autoclaving
    • QC testing after blending to verify chromogenic response and compliance with referenced assay standards

    Final product types

    • Dehydrated chromogenic media powder for E. coli detection
    • Ready-prepared selective agar plates for food and water analysis
    • Pre-poured microbiological test tubes and dipslides for hygiene monitoring

    2. Quality Control of Water Testing Kits

    The substrate sees application in manufacturing rapid test kits for municipal and industrial water quality monitoring. Regulatory bodies require these detection kits to differentiate E. coli reliably in processed and raw water. The manufacturing and formulation teams integrate the substrate into test vials or strips to enable accurate, color-based test results compliant with international drinking water regulations.

    Industry compliance standards

    • ISO 9308-1 and ISO 9308-2 for drinking and bathing water quality
    • US EPA Method 1604 (Colilert Test)
    • EN 26461 (Detection of coliform bacteria and E. coli in water)
    • Drinking Water Directive (EU) 2020/2184 requirements on microbial quality

    Typical usage ratio

    • Typical concentration: 45–70 mg per test preparation depending on test volume and sensitivity specification
    • Adjusted to optimize detection limits for various water sample matrices, including potable and recreational sources

    Downstream process integration

    • Blended directly into reagent mixtures or lyophilized substrates in single-use test vials
    • Integrated during strip impregnation phase for rapid semi-quantitative detection formats
    • Subject to batch-validation protocols: color yield, negative/positive control response, and shelf-life analysis

    Final product types

    • Rapid water testing vials for E. coli and coliforms
    • Colorimetric bacteriological test strips
    • Pooled batch reagent kits for laboratory and field water analysis

    3. Research Biochemical Assays for Enzyme Kinetics

    Academic and industrial R&D laboratories use this substrate in the assay development of beta-glucuronidase enzyme activity. Manufacturing teams producing diagnostic assay kits source the substrate for precise quantification applications. Accurate dosing and purity are vital to ensure reproducible research outcomes, especially for investigating microbial metabolism, recombinant enzyme function, and metabolic biomarker discovery in drug and environmental studies.

    Industry compliance standards

    • IUPAC protocol recommendations for enzymatic substrate assays
    • OECD Guidelines for the Testing of Chemicals (Section 3: Degradation)
    • Good Laboratory Practice (GLP) regulations (21 CFR Part 58, OECD Principles)
    • Supplier batch COA validation for substrate identity and purity >98%

    Typical usage ratio

    • Functional range: 0.05–1.5 mM substrate per assay well, adjusted per enzyme source and expected activity
    • Optimized trial-and-error during kit manufacturing process validation

    Downstream process integration

    • Weighing into master mix compositions or pre-dispensing into microplate wells for ready-to-use kits
    • Stability tests at varying pH and buffer conditions as part of manufacturing QC process
    • Final product release only after confirming batch-to-batch consistency in chromophore yield

    Final product types

    • Biochemical assay kits for beta-glucuronidase research
    • Reference reagent sets for in vitro enzyme studies
    • Standardized microplate reagent packs for high-throughput screening

    4. Evaluation of Bioremediation Activity in Environmental Monitoring

    Environmental laboratories and contract service providers adopt the substrate for detection and monitoring of glucuronidase-positive microbial populations during land and water bioremediation projects. The raw material enters routine testing for assessing degradation of contaminants and evaluating natural attenuation processes in regulatory-mandated site investigations. Manufacturers formulate custom field and bench test products for reliable performance in diverse sample matrices.

    Industry compliance standards

    • ASTM D5245 (Detection of E. coli in soils and sewage sludges)
    • OECD Series on Testing and Assessment (Biodegradation Monitoring)
    • US EPA SW-846 Method 1681 (Bioremediation monitoring QA/QC)
    • Accredited laboratory SOPs for site-specific bioremediation

    Typical usage ratio

    • Standard addition: 60–85 mg per liter sample suspension or as specified by validated field protocol
    • Adjusted based on soil/sediment organic content and expected contaminant concentrations

    Downstream process integration

    • Mixed into extraction buffers or enrichment broths during sample processing step
    • Packaged as part of field-deployable test cartridges or powder blends
    • Ongoing batch validation for substrate stability in offsite sampling environments

    Final product types

    • Field monitoring test kits for soil and groundwater remediation
    • Enzyme indicator reagent bottles for environmental survey programs
    • Contract lab validation kits for quantitative reporting of site clean-up

    5. Pharmaceutical Industry Microbiological Quality Control

    Pharmaceutical manufacturers integrate the substrate into routine microbial testing protocols to ensure non-sterile product batches comply with pharmacopeial microbial limits. Formulation groups in media production units use this reagent in selective media formulations validated for release and in-process checks. The precise use parameters are stipulated by in-house SOPs matched to international pharmacopoeia specifications, with focus on traceability and identity of microbial contaminants.

    Industry compliance standards

    • USP <61> and <62> (Microbial Limits Tests)
    • European Pharmacopoeia 2.6.13 and 2.6.12
    • ICH Q7 (GMP for Active Pharmaceutical Ingredients)
    • ISO 14698 (Biocontamination control in cleanrooms and controlled environments)

    Typical usage ratio

    • Standardized levels: 40–65 mg/L in compliance with validated media lot protocols
    • Adjusted in consultation with QA to harmonize across solid and liquid testing platforms

    Downstream process integration

    • Added to media during the batch blending step monitored under validated cleanroom conditions
    • Stability checked following autoclaving and prior to sterile filling
    • Comprehensive in-process QC and dual-release by QA and QC departments

    Final product types

    • Selective agar plates for pharmaceutical manufacturing quality control
    • Sterile-dosed media vials for finished product release testing
    • Environmental monitoring cassettes for cleanroom routine screening

    6. Industrial Hygiene Testing Solutions

    Specialty industrial hygiene firms and food safety labs utilize this substrate to develop and produce site sampling kits, designed for rapid surface monitoring of E. coli in food processing, beverage, and public facility environments. Accurate substrate dosage during the production of swab kits and dip tests is critical for credibility of positive and negative controls in routine industrial audits and HACCP compliance checks.

    Industry compliance standards

    • ISO 7218 (General requirements for microbiology examination in the food chain)
    • FDA 21 CFR 110 (Current Good Manufacturing Practice in Manufacturing, Packing, or Holding Human Food)
    • Codex Alimentarius microbiological criteria for food
    • ISO 18593 (Horizontal methods for surface sampling)

    Typical usage ratio

    • Application range: 35–60 mg per swab, dipper, or surface rinse test kit—depending on matrix and detection protocol
    • Kit-specific adjustments made during final blending and test validation stage

    Downstream process integration

    • Pre-mixed with buffer solutions for swab pre-moistening or surface contact application
    • Incorporated in dry or lyophilized pads for portable field use
    • QC batch testing for rapid and reliable chromogenic response under end-user conditions

    Final product types

    • Food industry surface swab E. coli detection kits
    • Portable hygiene test cards for factory and retail environments
    • Waterproof dipstick kits for beverage plant routine monitoring
    Free Quote

    Competitive 4-Nitrophenyl-Beta-D-Glucuronide prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Understanding 4-Nitrophenyl-Beta-D-Glucuronide: Practical Insight from the Manufacturer’s Bench

    Introduction to 4-Nitrophenyl-Beta-D-Glucuronide

    Working from the production floor up, every batch of 4-Nitrophenyl-Beta-D-Glucuronide (sometimes referenced as pNP-Glucuronide, model: NPBG-7587) reflects years of hands-on experience in carbohydrate chemistry. We developed this compound by refining our synthesis and purification methods to meet the rigorous demands of enzymology and research labs. Those familiar with glucuronidase assays know that substrate reliability doesn’t come by accident; repeated synthesis trials, adjustments to temperature controls, and strict moisture management shape every lot we deliver.

    4-Nitrophenyl-Beta-D-Glucuronide reaches you as a pale-yellow crystalline powder, a step beyond ordinary intermediates or clumsily mixed analogs. We see the difference under the microscope and in the purity audits: a consistent, low-impurity content, with negligible contamination by positional isomers or degradation products. The product typically meets purity thresholds of ≥99%, a standard we track for each shipment batch, as confirmed by HPLC and NMR.

    How Labs Rely on pNP-Glucuronide

    We built our process on feedback from academic labs, diagnostic kit developers, and industrial enzyme manufacturers. This compound, with its nitrophenyl group, allows for straightforward colorimetric detection — a simple visual cue directly tied to glucuronidase activity. Once beta-glucuronidase acts on it, the reaction yields 4-nitrophenol, a compound turning bright yellow under basic conditions and offering an absorbance peak at 405 nm. This brings clarity to kinetic readings and eliminates most background noise, critical for analysts tracking enzyme deficiencies, drug metabolism, or microbial contamination.

    Researchers with long-term projects emphasized the importance of storage stability. 4-Nitrophenyl-Beta-D-Glucuronide produced in-house resists degradation under proper conditions. Our tight water activity thresholds and packaging standards — stainless steel tools, amber glass, desiccant packing — proved their value when returning customers reported no unexpected signal drift, even a year after delivery.

    Weighed and tested with the end use in mind, the substrate dissolves easily in most common buffers, especially phosphate-buffered saline and Tris-based systems. Technicians saving time and frustration by eliminating remixing steps or unnecessary sonication speak for the value of straightforward solubility.

    Standing Apart: Real Differences from Other Substrates and Vendors

    Direct competitors often market their version of 4-Nitrophenyl-Beta-D-Glucuronide using broad claims about purity or batch consistency. In practice, several stumbling blocks keep coming up in lab reports. First, we’ve observed that off-the-shelf imports sometimes ship with trace solvents or unreacted starting materials, which not only affect assay background but complicate downstream data processing.

    We monitor for process residuals — specifically residual methanol, dichloromethane, and inorganic salts — using both GC-MS and ion chromatography. Any batch exceeding the threshold gets pulled from distribution. This level of self-scrutiny arises not from regulatory demand but from repeated customer findings, where even minor impurity spikes ripple through high-volume screening assays.

    Our QA team approached another common industry pitfall: batch variability. It isn’t enough to certify “greater than 99%” by an outside lab — we run year-on-year trending analyses and reserve archive samples from every lot. This internal record-keeping lets us catch subtle shifts in physical or spectral properties, which can throw off calibration curves in kinetic runs. By tracking melting points, UV-Vis spectra, and loss on drying for each production lot, we aim for repeatable results at scale.

    Why Enzyme Substrate Quality Matters from a Manufacturer’s Lens

    Every synthesis step, from the initial glycosylation to purification, leaves a footprint on enzyme substrate quality. In-house, minor handling missteps — a humid day, a deviation in crystallization temperature — show up later as “shadow” peaks in chromatograms or surprise lag phases in enzyme assays. Those shadow peaks translate into head-scratching results in pharmacology testing, where pNP-Glucuronide serves as more than a textbook substrate: It’s used in newborn screening, liver function panels, and microbial diagnostics.

    Some alternative products on the market use different glycosyl donors or skip a recrystallization phase to reduce costs or accelerate production. We field routine questions from researchers facing unexplained background absorbance or slow hydrolysis rates, often traced back to such shortcuts. Our team counters this by maintaining an unbroken cold chain where temperature excursions stay tightly logged and humidity sensors flag any breach, ensuring each vial ships uncompromised.

    The temptation in commodity chemical manufacturing drifts toward bulk contracts and batch blending. Open conversations with large-scale end users, especially those developing diagnostic kits under tight regulatory oversight, underscored the real cost of chasing low price at the expense of reproducible results. No researcher wants to rerun a plate reader experiment because a substrate lot changed week to week, and no kit manufacturer welcomes field complaints about faint controls or noisy baseline readings.

    Formulation, Stability, and Handling—Things Only Producers Worry About

    Most users confront 4-Nitrophenyl-Beta-D-Glucuronide as a finished reagent. We, as manufacturers, navigate a different reality, wrestling with shelf life, moisture absorption, and photostability challenges. Water content, even below 0.5%, can start to degrade the glycosidic bond at room temperature, generating faint notes of nitrophenol in storage (which shows up as ghost signals during assay prep). By rewiring our drying process — implementing low pressure, gentle heat, and immediate inert atmosphere transfer — we saw those byproducts drop to barely measurable levels.

    Some researchers report inconsistent results when using raw, off-patent supply chain material, especially in high-throughput applications or clinical screening. Our view is clear: only source batches where the degradation profile fits a flat, consistent baseline. Photodegradation risks, overlooked in poorly packaged goods, alter signal strength by breaking down the chromogenic end group even before assay. Hence, our supply chain insists on UV-resistant packaging and staged storage, a detail that left more than a few kit partners thankful following unexpected shipment delays during warm-weather months.

    We fielded requests for both micro-scale and kilogram lots, especially from pharma partners scaling up screening efforts. Commodity producers sometimes compromise purity for scale; we reject this approach. Custom batch sizes — from multi-gram analytical bottles to kilogram drums — each get tailored drying and packing steps, a solution that reduces cross-contamination and batch-to-batch “drift.”

    Navigating Regulatory and Testing Demands

    4-Nitrophenyl-Beta-D-Glucuronide found its footing in regulated environments. Diagnostic and pharmaceutical end users flagged two critical factors: raw material traceability and consistent lot certification. In our facility, each batch number tracks backwards to ingredient lot codes, operator logs, and equipment calibration sheets, supporting GMP and ISO 9001:2015 requirements as a matter of routine.

    Some competitors offer broad “for research use only” labels, sidestepping the discipline necessary to support regulated end uses. Our answer: summarize key batch data (purity, contaminant profile, storage history) in the accompanying certificate, matched by signed documentation and archive retention, so even years after shipment, labs can reconstruct assay history if needed. A few years back, this approach spared a major neonatal diagnostic team a costly recall, as we provided archived QA documentation resolving questions around substrate stability and assay reproducibility.

    Model Choice and What We Learned from Iteration

    Early on, we saw room for improvement in available commercial grades. Collaborators pointed out that batch-to-batch pH changes complicated buffer preparation. By standardizing our purification steps and minimizing adventitious acid pick-up during storage, we locked in a narrow pH range and eliminated a nagging source of inter-experiment variability. Our “NPBG-7587” build reflects this discipline — a tight melting range (171–175°C) and solubility profile (soluble up to ~50 mg/mL in water at 37°C, subject to buffer additives).

    Another upgrade came in optical clarity. Trace colored contaminants always skew background readings in UV-Vis applications. With analytical attention focused on the chromophore’s exact peak, we tuned our filtration and crystallization steps to suppress yellow-brown residues that snuck past earlier generations of the process. The result shows up in customer feedback: less need for recalibration, more confidence in signal interpretation, especially for multiplexed or automated diagnostic environments.

    Application Knowledge We’ve Gained from Real Users

    Collaboration with academic partners brought out patterns that books often miss. For example, in environmental testing—tracking beta-glucuronidase in water samples—operators flagged matrix effects from unexpected sample constituents. Our quality group addressed this by running interference checks with heavy metal salts and humic acids, confirming the substrate’s performance doesn’t waver with modest contaminant loads.

    Pharma groups running UGT (UDP-glucuronosyltransferase) activity tests highlighted another challenge: background hydrolysis. Even minimal spontaneous breakdown at storage or room temperature conditions eroded signal-to-noise ratios. Our approach focused on both bulk synthesis cleanliness and packaging innovations, directly improving sensitivity in chromatographic and microplate settings. Real-world customer validation — not just internal QA — kept us driving iterative improvements.

    Throughout different industry segments, from food safety to microbiome analysis, project scientists described the benefit of batch consistency. This consistency allowed them to use the same calibration data set for extended periods, leverage spare stock during supplier slowdowns, and trust post-shipment lot documentation in audits — all points reinforcing that product strength goes well beyond the chemical formula.

    Assay Design: Partnering with Developers and Diagnostics Manufacturers

    Feedback from diagnostics and life science firms refined our approach to product support. Some labs reached out with troubleshooting requests as they scaled from bench-top development to automated high-throughput platforms. Flow path contamination, false positives, and even unexpected foam formation in photoactivatable media arose when lower-purity substrate entered the workflow.

    We shared the following key takeaways, developed through years of scale-up support:

    From Manufacturing Perspective: The Future of Chromogenic Beta-Glucuronide Substrates

    Demand for pNP-Glucuronide continues to grow, driven by broader microbiological testing, personalized medicine, and more complex environmental monitoring. Diagnostic groups push for tighter performance thresholds, lower detection limits, and more automated assay pipelines. Each trend brings manufacturing headaches — stricter contaminant targets, higher lot traceability, greater focus on ecological packaging, and the looming expectation for synthetic chemistry with diminished environmental load.

    Our research group doubled down on greener synthesis, aiming for lower solvent consumption, improved atom economy, and recovery of glycosyl donors. Testing waste streams for residual pNP-Glucuronide and optimizing stepwise yields, we achieved lower byproduct formation — a win-win for both purity and sustainability. Other producers often lag in such improvements, especially in smaller jurisdictions or secondary markets.

    Raw material procurement matters. Beta-D-glucuronic acid comes in many grades, and minute differences in starting impurity levels can echo down the production chain. We enforce tight supply chain controls, bringing in trusted vendors with documented pesticide and heavy metal screens. Our customers notice the resulting confidence in their own regulatory filings, especially in regions requiring pharmacopoeia compliance.

    Practical Tips from an In-House Production Perspective

    Frequent calls come from lab workers seeking guidance on storage, use, and troubleshooting unexpected assay results with pNP-Glucuronide. Taking these calls shapes our supplier role. A few direct lessons resurface year after year:

    4-Nitrophenyl-Beta-D-Glucuronide in Context: Respecting What the Market Needs

    Years spent refining production lines reveal: Reliability and transparency matter more than brochure promises. Whether for individual academic researchers running a single set of ELISA plates, or multinational diagnostics firms requiring tons of finished product, the fundamental needs stay the same — trusted chemical supply, clear batch history, and total accountability in testing records.

    By fixing pitfalls experienced in earlier market generations, and responding concretely to labs’ feedback on what really disrupts outcomes, we continue to adapt both our material and paperwork. Rare compounds like 4-Nitrophenyl-Beta-D-Glucuronide play pivotal roles in health screening and applied research; we never take our stewardship of its integrity lightly.

    One element stays true year over year: Listening to the lived experience of working scientists, industrial chemists, and quality officers leads to better product and service. Our part in the supply chain — bridging chemical synthesis, documentation, and technical support — only improves so long as we remain transparent about both problems faced and solutions earned by hands-on production.