Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

4-Methylumbelliferone

    • Product Name 4-Methylumbelliferone
    • Alias 4-MU
    • Einecs 215-746-6
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    990100

    Cas Number 90-33-5
    Molecular Formula C10H8O3
    Molecular Weight 176.17 g/mol
    Iupac Name 7-hydroxy-4-methylcoumarin
    Appearance White to off-white powder
    Melting Point 194-197°C
    Solubility In Water Slightly soluble
    Purity ≥98%
    Fluorescence Excitation Maximum 360 nm
    Fluorescence Emission Maximum 450 nm
    Storage Temperature 2-8°C
    Synonyms 4-MU, Hymecromone
    Density 1.33 g/cm³
    Ec Number 201-993-5

    As an accredited 4-Methylumbelliferone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The packaging for 4-Methylumbelliferone (25g) features a white plastic bottle with a secure blue screw cap and detailed labeling.
    Shipping 4-Methylumbelliferone is shipped in tightly sealed containers to prevent contamination and moisture exposure. The chemical is typically packed according to regulations for non-hazardous materials, with labeling for identification. Standard shipping methods are used unless specific temperature control is required. Always handle and store in a cool, dry place upon receipt.
    Storage 4-Methylumbelliferone should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible substances like strong oxidizing agents. Protect it from light as the compound is light-sensitive. Store at room temperature or as indicated on the supplier's label. Ensure the storage area is clearly labeled and used only for chemical storage.
    Application of 4-Methylumbelliferone

    Applications of 4-Methylumbelliferone in Industrial Manufacturing

    4-Methylumbelliferone is a specialty ingredient with key roles across analytical biochemistry, pharmaceutical synthesis, enzymatic assay kits, and clinical diagnostics. As an original material manufacturer, we support diverse industry clients with stable supply, technical data, and integration guidance. Below are the principal, application-specific industrial uses based on actual downstream consumption patterns.

    1. Enzyme Substrate for Clinical Biochemical Assay Kits

    Many in vitro diagnostic manufacturers use 4-Methylumbelliferone as a fluorogenic substrate in quantitative enzyme assays, particularly for β-glucuronidase, β-galactosidase, sulfatase, and phosphatase determinations. Its unique fluorescent properties allow high-sensitivity detection of enzyme activity in human body fluid samples. Laboratories integrate this material at the initial manufacturing stage for bulk formulation of automated analyzer reagents and specialized assay panels for clinical diagnostics.

    Industry compliance standards

    • ISO 13485:2016 for in vitro diagnostics manufacturing
    • IVDR (EU 2017/746) device raw material traceability
    • CLSI EP05 for assay precision validation
    • FDA 21 CFR 820 QMS (for US device market)

    Typical usage ratio

    • 0.05 to 5 mM in finished reagent solutions, adjusted to enzyme specificity and instrument range
    • Exact concentration set according to kit manufacturer's analytical sensitivity and dynamic range requirements

    Downstream process integration

    • Added during bulk reagent compounding stage under controlled conditions
    • Processed in liquid filling lines or lyophilized as substrate tablets/powders before device assembly
    • Strict lot tracking for batch-to-batch consistency

    Final product types

    • Automated clinical chemistry analyzer kits
    • Point-of-care diagnostic cartridges
    • Enzyme-linked fluorescence immunoassay kits
    • Calibration standards for traceable laboratory testing

    2. Pharmaceutical Intermediate for Choleretic Drug Synthesis

    The pharmaceutical sector deploys 4-Methylumbelliferone as an active pharmaceutical ingredient (API) or an intermediate in the industrial synthesis of choleretic drugs. Facilities precisely dose and monitor the input during multi-stage organic synthesis workflows for controlled production of regulated oral tablet formulations and hospital infusions. Quality control laboratories assess purity, polymorphism, and residual solvent content, ensuring compliance with pharmacopoeia monographs throughout the processing chain.

    Industry compliance standards

    • Good Manufacturing Practice (GMP) per ICH Q7
    • ChP (Chinese Pharmacopoeia) / JP (Japanese Pharmacopoeia) / EP (European Pharmacopoeia) monographs for 4-Methylumbelliferone
    • ICH Q3C for residual solvents
    • FDA DMF (Drug Master File, for US-regulated products)

    Typical usage ratio

    • Varies per synthesis route, typically 1.0–2.5 equivalents relative to coupling partner
    • Input quantity based on scale (hundreds of grams to hundreds of kilograms per batch)

    Downstream process integration

    • Charged into stepwise synthesis reactors under nitrogen protection
    • Isolated by crystallization before further conversion or direct tableting
    • Subject to in-process HPLC and FTIR testing for stage release

    Final product types

    • Prescription-grade choleretic tablets (e.g., Hymecromone 200 mg, 400 mg)
    • Hospital compound infusions
    • Pre-formulation granules for hospital compounding pharmacies
    • Regulatory document reference standards

    3. Research-Grade Fluorescent Marker Production

    Research reagent manufacturers rely on 4-Methylumbelliferone for high-purity applications in bioanalytical fluorescence tracing and cell-imaging studies. Its chemical structure enables labeling of sugar conjugates, nucleic acids, and peptides for visualization in academic and industrial R&D settings. In-house refiners process bulk lots to ultrapure grades and tailor the formulation for downstream conversion to conjugate probes and molecular assay standards.

    Industry compliance standards

    • ISO 9001-certified quality management for research chemicals
    • REACH Regulation (EC) No 1907/2006, Annex XVII for laboratory reagent safety
    • GHS/CLP labeling rules for chemical traceability
    • Purity verification per customer certificate of analysis (CoA) specifications

    Typical usage ratio

    • 5 μg/mL to 1 mg/mL in labeling reactions, optimized for target molecule concentration
    • Purification and formulation tailored for research-grade probe kits and reference standards

    Downstream process integration

    • Integrated into conjugation workflows for labeled glycosides and nucleotides
    • Pre-purified and lyophilized for long-term research storage
    • Packed into single-use or multi-use research vials in ISO class 7 cleanrooms

    Final product types

    • Fluorescent-labeled substrate libraries
    • Standard addition calibration solutions
    • Cell-imaging bioassay reagents
    • Custom high-purity fluorometric reference materials

    4. Raw Material for Food Quality Control and Residue Testing Kits

    Specialist manufacturers supply 4-Methylumbelliferone to food safety laboratories for use as a substrate in rapid detection kits targeting microbial contamination or pesticide residues. The compound's fluorescence under UV excitation supports sensitive readout of enzymatic or chemical reactions in processed food matrices. Laboratories require high batch consistency and certified impurity profiles before formulating single-use assay components for deployment in regulatory and factory settings.

    Industry compliance standards

    • ISO/IEC 17025 laboratory accreditation for food analysis
    • Codex Alimentarius on food testing reagents
    • EU Regulation (EC) No 882/2004 for official controls in food safety
    • US FDA GFSI food laboratory requirements

    Typical usage ratio

    • Approximately 0.1 to 1 mM in prepared single-use test ampoules, tuned according to matrix interference and detection target
    • Formulation design based on anticipated food or residue levels

    Downstream process integration

    • Incorporated into pre-mixed enzymatic assay kits during in-house liquid blending
    • Dispensed and sealed via automated filling for retail or laboratory package sizes
    • Subject to performance validation for each novel test matrix

    Final product types

    • Rapid enzyme-based food residue detection kits
    • Contamination control strip assays for dairy or fruit juice testing
    • Lateral-flow test cassettes for field or factory environments
    • Official food analysis reference substrates

    5. Quality Control Reference Standard in Analytical Laboratories

    Analytical and calibration laboratories use reference-grade 4-Methylumbelliferone to validate and quantify method performance for pharmaceutical, food, and environmental matrices. Stringent documentation and traceability govern both production and supply, supporting traceable calibration chains for HPLC, fluorimetry, and mass spectrometry equipment. Facilities specify high-purity lots, clear impurity fingerprinting, and stable packaging to prevent degradation during repeated QC analyses.

    Industry compliance standards

    • ISO 17034:2016 for reference material producers
    • USP Reference Standard Certification
    • EA-4/02 calibration certificate requirements
    • OECD Good Laboratory Practice (GLP) for analytical laboratories

    Typical usage ratio

    • Standard concentrations range from 1 ng/mL to 50 μg/mL in calibration protocols
    • Amount tailored per validated SOP and matrix complexity

    Downstream process integration

    • Prepared as stock calibration solutions by dissolution in methanol or buffer
    • Aliquoted into secondary containers for routine laboratory calibration
    • Used in daily system suitability and instrument qualification workflows

    Final product types

    • HPLC and UPLC method calibration standards
    • System suitability test mixtures
    • Spike-in recovery controls for matrix effect studies
    • Official pharmacopoeial reference lot shipments
    Free Quote

    Competitive 4-Methylumbelliferone prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Understanding 4-Methylumbelliferone From the Manufacturer's Bench

    The Chemistry and Quality That Matters

    In the business of specialty chemicals, few products draw as much attention in research circles as 4-Methylumbelliferone (often known as 4-MU or Hymecromone). Working daily with tons-scale quantities of this compound, we recognize more than its CAS number or bright blue fluorescence – we see its true nature under the lens of process controls, purity benchmarks, and the needs of real scientists pushing their projects forward. As chemists and technicians, our experience stretches from the reactor to the analytical lab. Through years of repeated synthesis, analysis, and trouble-shooting, we’ve seen how this molecule reveals the strengths and vulnerabilities of any manufacturer’s upstream equipment and quality ethos.

    4-Methylumbelliferone's core utility comes from its dual role: on one side, it’s a reliable, cost-effective diagnostic substrate in fluorescence-based enzymatic assays; on the other, it anchors several key intermediates in pharmaceutical and biochemical syntheses. What distinguishes our manufacturing operation is the deliberate engineering of every batch for low impurity levels. We push every run through HPLC and LC-MS checks not just to print out a certificate, but because we understand that even the smallest oxidative byproduct or isomeric impurity misleads research. It isn’t enough to hit a high assay value; it’s about clean spectra, batch after batch, so biologists don’t spend weeks chasing artefacts or dealing with variable activity.

    How We Approach Production of 4-Methylumbelliferone

    Let’s talk about the product itself. 4-Methylumbelliferone, model number UM4001 in our catalog, features a fluorescence peak that is sharp and strong, making it a gold standard in research kits for detecting glycosidase or glucuronidase activity. Chemically, the structure carries a methyl group at the 4-position of the umbelliferone core, creating a molecule that’s both stable and responsive in most aqueous buffers. Cheaper imitations usually cut corners with raw material grades or skip certain purification washes. Through feedback from both in-house and external labs, we take steps to keep batch moisture, trace metals, and residual solvents far below agreed-on tolerance limits.

    We run itself each reaction batch through a series of visual and instrumental tests. The pale crystalline powder may look unremarkable to the naked eye, but laboratory testing tells us the essential story. 4-Methylumbelliferone’s spectral purity directly impacts the sensitivity of quantitative fluorescence readings– a lesson we learned when several research groups approached us about ‘flicker’ signals in their fluorescence data while using competitive imports a few years ago. After investigating the matter, we traced the issue to trace fluorophore byproducts. From that point, our production team began routine fluorescence lifetime measurements and demanded chromatograms showing a signal-to-noise ratio above 98 percent for every released batch.

    Technical Specifications and What They Mean in Real Work

    UM4001 typically leaves our warehouse at 99.5%-plus purity by HPLC, with water content below 0.2 percent as measured by Karl Fischer titration. These numbers didn’t come from marketing decks – they’re the result of analytical bottlenecks, repeated tweaks to crystallization, and conversations with QC chemists who have to chase down every ‘ghost peak’ after a cyclization run. Purity isn’t just a checkbox. Even sub-one-percent impurity can include O-methylation byproducts, process acid residues, or dibenzofuran analogues, which sabotage sensitive downstream work. We document every deviation, not just because regulatory agencies expect it, but because it spares both us and our customers surprise headaches.

    For researchers using UM4001 in kinetic studies or forensic workflows, one major concern is reagent stability under both room temperature and refrigerated storage. Our formulation holds steady for over two years in a sealed, desiccated container, based on ongoing shelf-life studies. Ambient light does eventually lead to slow decomposition due to the extended conjugated system, so we use UV-protectant bottles in the packaging process – an adjustment that came directly from field feedback by microbiology users tired of seeing drift over time in control solutions.

    The Impact of Minor Details: Lessons from the Factory Floor

    We’ve lost count of how many times minor deviations in washing solvents or temperature profiles have led to visible changes in fluorescence output. These aren’t just technical footnotes: the way we wash away tert-butanol after recrystallization has shifted over years, based on full-spectrum IR results showing lingering alcohol peaks in early batches. Each process adjustment pairs with real consequences for enzymatic activity readouts and background interference in users' hands. No one wants to explain weird baseline shifts or unexplained signal dampening in peer-reviewed projects due to something as mundane as a poorly timed solvent switch. Every small habit at the plant – whether insisting on triple-filtered process water or using new glassware for the final recrystallization – saves troubleshooting in the research lab months later.

    It’s these lessons – often learned the hard way, through failed batches and after-hours analytical reports – that underline why technical prowess matters with a specialty fluorogenic product. Every gram tells a story from upstream material to finished vial. In making thousands of kilograms over the past decade, we’ve seen the ‘batch-to-batch consistency’ catchphrase only means something if every shift change is trained on the same painstaking routines, documented with the right analytical backup, and never left to just ‘good enough’. We still get calls from labs burned by inconsistent lots from ambiguous origins, occasionally sent our way to troubleshoot sticky product left behind in sample wells or unexplained color shifts.

    User Experience: Feedback That Shapes Every Detail

    Large-scale chemical manufacturing lives and dies by its relationships with laboratory users. Since our foundation, we’ve kept doors open to customers and research groups, inviting them to audit the process, run pilot vials, and critique anything off-spec. Once a global biotech firm flagged inconsistencies in fluorescence under different buffer conditions. Our R&D team worked side-by-side with their scientists to tease out subtle differences caused by carbonate buffer interactions. We altered the final rinse from DI water to trace-acidified water, eliminating the artifact for all subsequent production batches.

    Researchers in cytochemistry, enzymology, and environmental analysis have also called attention to the difference in response between our 4-Methylumbelliferone and lower-purity competitors. It’s not unusual for sample prep technicians to bat the issue back and forth with us over email or the phone – discussing everything from solubility in high-salt mixes to the persistence of slight yellow tinge in concentrated form. We use these exchanges as live feedback: direct troubleshooting becomes factory process notes. There’s nothing hypothetical about the problems research labs face, and we wouldn’t stay in business if we didn’t act on every valid complaint. The way the product dissolves, precipitates, and performs under demanding assay cycles all play into process changes.

    Applications Led by Real-World Results

    Across all chemical suppliers, 4-Methylumbelliferone appears routinely in academic papers, enzyme test kits, diagnostics labs, and pharmaceutical syntheses. Our main customer base draws from scientists using the compound for detection of β-glucuronidase activity – a crucial indicator in both clinical diagnostics and pharmaceutical screening. Analytical chemists turn to 4-MU for its bright, stable blue fluorescence at 450 nm after hydrolysis, which stands out clearly against common background noise in liquid systems.

    Quality control in our setting keeps an eye out for photochemical artifacts, since these can influence both the intensity and consistency of the assay signal. Several teams have shared challenges experienced with products from less meticulous sources, including erratic response curves and high baseline noise. Our rigorous control on both purity and water content contributes directly to reproducibility in those fields. We supply both research-scale glass vials and larger industrial packaging; in both forms, the material remains free-flowing with no caking or pinkish discoloration, which would otherwise indicate partial oxidation.

    For pharmaceutical intermediates, users often select our product for its readily derivatizable methyl group. The molecule’s structure provides a platform for specialized coupling reactions or as a stepping stone for more complex active substances. We’ve fielded queries from both medicinal chemists and production pharmacologists looking for documentation about minor isomer content or trace metals—concerns that we answer with every full factory run, providing not just compliance but detailed batch history. Our plant analytics link directly to customer confidence.

    Standing Out: What Makes Our Manufacturing Different

    Emphasizing in-house production, we avoid sub-contracting and clandestine blending that fast-moving distributors often practice. The product doesn’t just reflect assay value but is a testament to the technical staff, from reactor operators to analytical chemists, who together diagnose every possible problem and share it up the management chain. Every time an operator spots a cloudy filtrate or an unexpected orange hue, it translates into lab work, protocol review, and a shared lesson documented for the next batch.

    In a world where chemical catalogs swell with numerous offer sheets, anyone shopping for 4-Methylumbelliferone confronts a bewildering field of options: numerous grades, changing sources, and wide price differences. Real production differences matter more than catalog copy. Some suppliers quietly mix batches from several sources or mask slight discolorations with added sorbents. We’ve had to explain to end users how blended materials, though seemingly meeting ‘purity’ numbers, often show wider melting points and inconsistent response curves—a challenge in precise kinetic assays.

    Our approach focuses on no-nonsense transparency. We share analytical data, openly report internal investigations into off-spec events, and do not dump low-end material onto the market. Our rationale is simple: chasing quick volume by discounting out-of-grade material always comes back as lost confidence, tough phone calls, and missed reorders. Each run of UM4001 gets tracked by production shift, full analytical chain, and a unique batch code easily referenced by customers with a phone call or email.

    Environmental Perspective and Safety Considerations

    Handling 4-Methylumbelliferone in bulk doesn’t just mean moving drums and boxes. The compound’s relatively low toxicity, compared to some related coumarin derivatives, keeps general safety measures manageable. But we don’t get complacent. Any dust, especially in drying and milling stages, receives full containment and extraction controls to avoid respiratory exposure. Our protocols balance tight process control with staff safety, using sealed transfer vessels and real-time air quality monitors during major load-outs.

    Waste management earns just as much attention as quality control. Synthesis produces side streams containing minor aromatic byproducts and organic wash liquids; our plant channels all effluent through on-site solvent recovery and neutralization. By keeping close records on solvent cycles, distillation yields, and emissions, we provide traceable documentation not just to regulators but to users who demand full accountability from their suppliers. As pressure grows from all corners on chemical plant emissions, our plant updates handling and abatement technologies yearly, learning from both audits and third-party evaluations.

    Comparing 4-Methylumbelliferone with Other Fluorogenic Substrates

    Those involved in enzyme assay development know that alternative fluorogens, such as 4-methylumbelliferyl-β-D-glucuronide, AMC (7-amino-4-methylcoumarin), or fluorescein derivatives each come with distinct profiles. What keeps 4-MU a laboratory staple is its signal clarity, the reliability of excitation/emission profiles in aqueous phase, and broad compatibility with most commercial fluorescence plate readers. Some substrates give brighter initial signals or different color profiles, but they aren’t as stable under storage or are prone to decomposition when exposed to common organic solvents. Over years spent supporting method development, we’ve witnessed 4-MU outperform newer ‘hot’ compounds precisely because it resists hydrolysis and contamination across a wider pH and solvent range. That repeatable, trusted behavior matters more than promises of ‘brighter’ fluorogenic performance for most bench scientists.

    Pharmaceutical companies often require fluorogenic markers that will stand up to scale-up demands. Some alternative coumarins degrade or yield variable byproduct content at scale, often undetected until late in development. Through constant process improvement, tight supply chain oversight, and in-house trace impurity mapping, we keep UM4001 snugly within specification year-round.

    Anticipating and Solving Customer Challenges

    Bringing a specialty chemical to research and industrial users rarely unfolds smoothly. Real people, not lab robots, use every bottle. With 4-Methylumbelliferone, challenges usually pop up in two places: unexpected solubility changes (from batch variability or container conditions) or unexplained fluorescence artefacts (from handling or storage). Every year, one or two incidents prompt internal ‘blamestorms’ where we sift through logbooks, equipment maintenance, weather records, and operator notes searching for irregularities. Transparency with our customers builds trust, so we always circle back with answers—even if the culprit is something as old-fashioned as a cracked desiccant cartridge in one outgoing case.

    Solutions often mean redesigning processes. Last year, a case of subtle fluorescence drift across lots forced a change in the milling protocol to avoid trace metal pick-up from stainless steel. We track every outlier case; learning from mistakes turns into new SOPs and operator briefing notes. Site tours and collaborative QC checks are routine for large customers, and many improvements stem from real-world user suggestions rather than detached R&D brainstorming.

    Shipping can add to the story. During a humid summer, several export shipments flagged for minor moisture uptake prompted a complete overhaul of final packaging—the addition of humidity indicators in each box, more moisture-absorbent liners, and a tweak to inner-seal protocols. These concrete, measurable improvements mean that quality stays reliable not just inside our factory but in customer hands across the world.

    Looking Forward: Challenges and Innovations Ahead

    4-Methylumbelliferone continues to play a growing part in new diagnostic technologies and next-generation drug synthesis. As the expectations of both regulators and customers intensify around traceability, disclosure, and process safety, our plant sets ambitious targets to cut process residuals further, lower solvent footprints, and pursue greener synthetic routes. We experiment with new catalyst and solvent systems, eager to push both operational excellence and sustainable chemistry. Each change undergoes scrutiny by our best technicians and analytic chemists, tested for full interchangeability with long-standing batch records.

    As users look for documentation about every raw material, trace impurity, and environmental detail, we answer with full-run analytics and open lines for technical feedback. Over time, this compound has taught factories like ours patience, discipline, and the value of sharing knowledge up and down the supply chain. New challenges will surely arise, but every answer earned here builds strength in both product and reputation.

    From raw intermediate to finished, packed chemical, every container of UM4001 reflects the reality of chemical manufacturing: challenges met, mistakes learned from, and quality earned through daily discipline. The story of 4-Methylumbelliferone is more than a sequence of numbers or catalog listings – it is a testament to the collaboration between factory floor, analytical lab, and demanding researchers aiming for the next breakthrough.