|
HS Code |
113502 |
| Product Name | 4-Fluoro-3-Nitrobenzyl Bromide |
| Cas Number | 462070-20-4 |
| Molecular Formula | C7H5BrFNO2 |
| Molecular Weight | 234.02 g/mol |
| Appearance | Pale yellow to yellow solid |
| Melting Point | 53-56°C |
| Purity | Typically ≥98% |
| Solubility | Soluble in organic solvents (e.g., DMSO, DMF) |
| Smiles | C1=CC(=C(C=C1F)NO2)CBr |
| Inchi | InChI=1S/C7H5BrFNO2/c8-4-5-1-2-6(9)7(3-5)10(11)12/h1-3H,4H2 |
| Storage Temperature | 2-8°C (Refrigerated) |
| Synonyms | α-Bromo-4-fluoro-3-nitrotoluene |
As an accredited 4-Fluoro-3-Nitrobenzyl Bromide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Amber glass bottle containing 25g of 4-Fluoro-3-Nitrobenzyl Bromide, securely sealed with a screw cap and labeled with hazard warnings. |
| Shipping | 4-Fluoro-3-Nitrobenzyl Bromide is shipped in sealed, inert containers to prevent moisture and light exposure. It is labeled according to hazardous material regulations and handled with care due to its toxic and irritant properties. Compliance with national and international chemical shipping guidelines is strictly maintained during transit. |
| Storage | **4-Fluoro-3-Nitrobenzyl Bromide** should be stored in a tightly sealed container, away from moisture and light, in a cool, dry, and well-ventilated area, ideally at 2-8°C (refrigerator). It should be kept away from incompatible substances such as strong bases, strong oxidizing agents, and strong acids. Use appropriate personal protective equipment when handling to avoid exposure. |
Applications of 4-Fluoro-3-Nitrobenzyl Bromide in Industrial Manufacturing
1. Active Pharmaceutical Ingredient (API) Intermediate Synthesis
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Agrochemical Synthesis: Herbicide and Fungicide Intermediates
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Specialty Dye and Pigment Manufacturing
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Chemical Sensors and Analytical Reagents Production
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Advanced Polymer and Material Science Applications
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 4-Fluoro-3-Nitrobenzyl Bromide prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Producing 4-Fluoro-3-Nitrobenzyl Bromide has given us a practical sense of what precise aromatic substitution means for both the chemistry and the real-world uses of this compound. Our staff, with decades in benzyl halide synthesis, has handled each batch with the type of attention that only comes from understanding where the product ends up and why those details matter. From purity requirements, by-product profiles, to safe shipment, we recognize the value brought by each tailored specification.
During crystallization and drying, appearance stays consistent—white to off-white solid, showing we’ve met the standards a synthesis chemist expects. High-resolution spectra back each lot. Examined directly on the shop floor and cross-checked in quality labs, we see narrow melting ranges that reflect minimal side-product formation. Moisture content often comes up in formulations, so our process control keeps water below 0.1%. Purity by HPLC usually tops 98%, factored by practical separation during purification rather than just pushing numbers. This lets bench chemists rely on accurate molecular weights in yield calculations.
Experience shows laboratory requests are rarely arbitrary. The para-nitro or ortho-fluoro influence more than reactivity, impacting deactivation of the aromatic ring or nucleophilic substitution rates. In 4-fluoro-3-nitrobenzyl bromide’s case, we work with a benzene ring carrying both electron-withdrawing (nitro) and electron-withdrawing-but-less-aggressive (fluoro) groups at critical loci. This arrangement means activation for SN2 reactions occurs not just at the benzylic carbon, but also defines selectivity in downstream workups. The difference from simple benzyl bromide is distinct—the presence of both fluoro and nitro functional groups tune electron density and partway dictate both physical handling and chemical compatibility.
Academic teams and R&D chemists choose this molecule with conversion steps in mind. Beyond obvious arylation or amine functionalization, it provides an entry point for the building of fluorinated or nitroaromatic scaffolds, seen in agrochemical research, advanced materials, and the search for novel bioactive agents. Alkylation of sensitive heterocycles, selective deprotection strategies, and SN2 displacement reactions proceed smoothly, provided good process controls at our end and fresh, uncontaminated stock. We field regular questions on solvent compatibility, and based on long experience, advise dry DMF or DMSO when attacking with nucleophiles—avoiding protic solvents reduces side hydrolysis.
Working directly with pharmaceutical R&D means we’re sometimes asked to tweak parameters for downstream safety. Some labs request tailored lot sizes or one-off drum packaging. We know from experience that storage at low humidity and away from light keeps the product stable for longer periods, and we prepare all dispatches with this in mind. The hydrophilicity from the nitro group and increased metabolic stability from fluorination give drug developers reliable handles for further derivatization. This compound serves both core and side-chain modification steps, especially where existing commercial benzyl bromides either overreact or introduce unwanted impurities. The presence of fluorine expands the options for late-stage functionalization in medicinal chemistry efforts.
Watching side-by-side reactions in our pilot plant provides insight others might miss. Compare basic benzyl bromide to 4-fluoro-3-nitrobenzyl bromide: The electron-poor ring in the latter sharply reduces side reactions during nucleophilic substitution. Less electrophilic variants often linger in reaction mixtures, needing extra cleanup—resulting in more solvents used and lost time. The difference between ortho and para substitution isn’t just trivial; this specific substitution pattern blocks certain unwanted byproduct channels, lowering tarring and resin development. The NO2 group’s influence gives technicians a wider safety window when scaling up, as runaway exotherms become less likely under controlled additions of nucleophiles.
We see fewer requests for 4-fluorobenzyl bromide or 3-nitrobenzyl bromide by themselves. Combined, the dual functionalization improves selectivity for research teams, particularly in strategies where two chemical “handles” are needed. With drug synthesis, late-stage fluorination grows ever more important for metabolic stability profiling, and our experience shows a distinct preference among discovery chemists for pre-fluorinated intermediates.
Years of running aromatic halogenations and selective nitrations have shaped how we scale this compound. Each batch starts from fluoronitrotoluene, avoiding isomer mixtures via tight temperature control and reagent stoichiometry. Batch consistency only comes from direct attention to every filtration, wash, and crystallization stage—not just running to a setpoint and waiting for completion. Our reactors run jacketed and set at reduced pressure, since the solid product shows thermal sensitivity if held high for long periods. Bromination at the benzylic position gets finicky, so we keep side product bromination of the aromatic ring almost undetectable—lab GC spectra prove this out.
Drying brings its own challenge. Without careful watch, picking the right vacuum and heat rate leads to caking and tough post-processing, so we train technicians to spot telltale signs of surface hardening before it turns into a compaction headache. Because trace HBr and water bring down purity, our QC team works closely with each lot. No single monitoring stage guarantees purity—routine chromatography, melting point tracking, plus NMR and mass spec at critical steps ensure downstream users get the product profile they expect.
Working with benzyl bromides means real risk mitigation, not just on paper, and our protocols have evolved with firsthand incident reviews. We’ve added local exhaust and push for closed transfer where possible, keeping operators from routine exposure. Gloves, safety shields, and goggles aren’t suggestions. We teach all incoming operators about the effects of trace vapor or dust, as accidental skin or airborne exposure, even in small doses, can cause irritation. Over years, we’ve moved from open-top weighing to direct-from-drum feed when possible, believing those small shifts add up dramatically in reducing daily hazards.
Strong, pungent odors sometimes warn of process leaks. Prompt cleanup and restricted area maintenance beat any written policy. We depend on fresh ventilated spaces, replace filters on a schedule, and expect every worker to carry spill neutralizer, not just rely on central storage. Packaging aligns with real handling limits; we use double-bagging and containers rated for moisture and UV protection, knowing temperature excursions can ruin several drums overnight. Orders often come with specific shelf life requests; these are honored by batch dating and refraining from overstretching projected stability.
Quality in benzyl bromide derivatives never comes by accident. A blend of technology and diligence paves the way for consistent 4-fluoro-3-nitrobenzyl bromide. Raw materials are screened at intake for both isomer and trace contaminant levels. In-process sampling follows a checklist refined by years of missed yields and operator debriefs. We’ve scrapped batches when HPLC finds even a half-percent unknown peak. Modern NMR and LCMS give us direct confirmation for every lot before final approval. We keep a library of control spectra from every campaign, matching incoming analyte splits for regular comparison.
End use requirements dictate final QC standards. Drug and material labs expect documentation and independent third-party validation. We invest in regular method review and internal “blind” cross-checks—technicians sometimes retest “unknown” samples against previous lots, hunting any drift in spectra or melting points. That approach, demanded by clients with routine filings, spots subtle changes before they become compliance issues. Trace metals are checked after requests from clients needing catalyst-free pools. We’ve reduced them to single-digit ppm. Experience shows these steps keep nonconformities off the table and help researchers meet regulatory and patent defense thresholds.
Real-use logistics rarely fit theoretical models. Customers order from sub-gram vials to small drums, depending on research intensity or campaign scale. We’ve found triple-seal liners perform best for moisture exclusion. Labels go beyond a simple name; every drum ships with direct reference spectra, traceable lot codes, and confirmed QC signatures. In regions with high humidity, we coordinate cold chain options—even arranging storage at customers’ sites ahead of time to prevent degradation. Transport testing combines vibration, heat, and light exposure—once we learned the hard way, after an overseas shipment lost prime product to a cracked seal under tropical heat.
Each client prioritizes slightly different documentation. Some demand chromatograms attached to every drum, others want NMR or MS hard copies with periodic analysis routines. We maintain digital libraries but also keep hard-bound lab books for every production run, reviewed regularly and stored by date and lot number. Any deviation triggers full batch review and, if necessary, targeted customer notification well ahead of shipment, rather than at the border or during receiving. This approach minimizes unplanned downtime, a frequent pain point in global manufacturing supply chains.
Working with regulated clients, we keep full transparency in lot origins and control steps. Batch records, spectra, and analytical data archives remain on hand for all clients demanding audit-ready evidence. Certificates of Analysis match shipment lots—never mixed or generalized. Some labs require prior notification before batch runs, especially if modified raw materials or new synthesis routes are proposed. Decade-long relationships with compliance officers on the client end remind us to keep revalidation routines regular and documentation ready for review at any stage. A missed documentation step doesn’t just risk a failed delivery, but impacts team credibility and downstream research budgets.
Sustaining reliable production takes more than standard operating procedures. In our plant, we assign batch custodians—one expert follows the compound from raw intake through packaging. If a pump or filter behaves oddly, that technician investigates, keeping a running log. This practice has forced us to identify, trace, and fix bottlenecks before they become lost batches. It’s not just the operations manuals that guide us, but lived experience and a knowledge base built by teams who have faced, and solved, recurring issues. Technical meetings review every missed yield or impurity spike, drawing on plant data and cross-site expertise from others who have faced the same reactions and analytical hiccups.
Every now and then, research partners push for changes in the synthetic approach to accommodate new reagents or downstream protocols. We conduct controlled trials, cross-referencing yield, safety margin, and isolated product quality. Not all tweaks succeed—sometimes byproduct profiles worsen, or scale-up energy costs rise. Adjustments are data-driven, supported by thorough analysis rather than hopeful trial-and-error. Retrospective reviews catch trends across years, not just the last batch. Disaster is most often averted not by a single person’s call, but by an experienced group aware of the nuances in every production stage.
We routinely seek end-user feedback to shape future batches and improve formulations. Researchers comment on solubility, stability, and handling quirks; we take those directly to our process team and formulate adjustments where possible. Whether customers raise concerns about flow rates for automated reactors, dust formation during open transfer, or even labeling language, each point enters our review cycle. We’ve made real changes based on these discussions—lower-dust blends, rapid-melt granulation for quick charge to reactors, or custom bottle necks for glovebox work. Innovation comes as much from these communication loops as from in-house development.
Production processes keep evolving as new analytical tools and reactor controls come online. Our team prioritizes continuous learning, attending technical sessions, and updating SOPs based on validated evidence. We remain open to new purification and packaging technologies, always seeking ways to boost quality, efficiency, and environmental safety. Our job grows along with our customers’ expectations and breakthroughs, giving meaning and purpose to every gram shipped.
Our work as a manufacturer means each lot of 4-fluoro-3-nitrobenzyl bromide reflects both long-term chemical knowledge and a practical awareness of how labs need materials. Every kilogram, every vial—and even every rejected batch—stands as proof of a production process that never stays still or gets stuck in old ways. We adapt and improve, keeping reliability at the forefront. Our experience tells us where short-cuts hurt and where real gains can be made for chemists relying on this material to advance their work. That unwavering focus on substance, safety, and communication drives what we do, differentiates us from traders, and supports a higher level of trust in our products.