Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

4-Bromo-2-Fluorobenzylamine Hydrochloride

    • Product Name 4-Bromo-2-Fluorobenzylamine Hydrochloride
    • Alias 4-bromo-2-fluorobenzylamine HCl
    • Einecs 812-208-7
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    266495

    Product Name 4-Bromo-2-Fluorobenzylamine Hydrochloride
    Cas Number 1072952-27-4
    Molecular Formula C7H7BrFN·HCl
    Molecular Weight 240.50 g/mol
    Appearance White to off-white solid
    Melting Point 160-164°C
    Solubility Soluble in water
    Purity Typically ≥98%
    Storage Temperature 2-8°C
    Synonyms 2-Fluoro-4-bromobenzylamine hydrochloride
    Smiles NCc1ccc(Br)cc1F.Cl
    Inchikey ZNJCVQDRFNOHLL-UHFFFAOYSA-N
    Hazard Statements May cause skin and eye irritation

    As an accredited 4-Bromo-2-Fluorobenzylamine Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing White plastic bottle labeled "4-Bromo-2-Fluorobenzylamine Hydrochloride, 25g," with hazard symbols, lot number, and manufacturer's details.
    Shipping 4-Bromo-2-Fluorobenzylamine Hydrochloride is shipped in tightly sealed, chemical-resistant containers to prevent contamination and moisture ingress. It is packaged according to relevant hazardous material regulations, typically in compliance with UN and IATA guidelines. The package includes clear labeling, safety documentation (SDS), and temperature control instructions if required.
    Storage 4-Bromo-2-Fluorobenzylamine Hydrochloride should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers. Store at room temperature, typically between 15–25°C (59–77°F), and always follow local regulations and safety guidelines for handling chemical reagents.
    Application of 4-Bromo-2-Fluorobenzylamine Hydrochloride

    Applications of 4-Bromo-2-Fluorobenzylamine Hydrochloride in Industrial Manufacturing

    4-Bromo-2-Fluorobenzylamine Hydrochloride finds reliable industrial applications as a specialized intermediate in regulated sectors. Its unique chemical structure enables downstream producers to synthesize advanced pharmaceutical compounds, crop protection actives, and specialty materials. The following section provides an in-depth review of its established usage scenarios across the life sciences and chemical manufacturing landscape.

    1. Small-Molecule API Synthesis in Pharmaceutical Manufacturing

    This compound serves as a core building block for synthesizing next-generation small-molecule active pharmaceutical ingredients, especially within targeted oncology and central nervous system drug pipelines. Pharmaceutical formulation teams integrate it into heterocyclic condensation or reductive amination steps to construct complex molecular backbones, making it indispensable for medicinal chemistry groups developing patent-protected molecules. Adherence to validated GMP practices ensures traceability and consistent output.

    Industry compliance standards

    • ICH Q7 Good Manufacturing Practice for Active Pharmaceutical Ingredients
    • 21 CFR Part 210/211 (FDA cGMP for drugs)
    • European Pharmacopoeia monographs as applicable to finished API
    • USP General Chapter <464> Synthesis and Characterization

    Typical usage ratio

    • 0.5% – 3.2% molar equivalent relative to target API batch size, adjusted per synthetic route and impurity profile requirements

    Downstream process integration

    • Employed in the early- to mid-phase reaction sequence for introducing substituted benzylamine motifs, either in stepwise amide bond formation or reductive coupling processes, prior to crude purification and subsequent derivatization

    Final product types

    • Targeted anti-cancer small molecules
    • CNS-active pharmaceutical intermediates
    • Oral and parenteral API forms for late-stage clinical and commercial drug products

    2. Agrochemical Intermediate in Herbicide Synthesis

    Selective herbicide manufacturers rely on the compound as a key amine-functionalized precursor for assembling fluorinated aryl derivatives critical to modern agro-active molecules. Its electron-rich characteristics enhance specificity in forming stable amide linkages required in high-performance herbicide scaffolds, meeting stringent quality benchmarks for environmental safety and residue control in agriculture.

    Industry compliance standards

    • FAO/WHO Specifications (JMPS) for pesticide active ingredients
    • ISO 9001:2015 Quality Management for agrochemical intermediates
    • REACH Annex VIII (EU) for specialty chemical intermediates
    • EPA 40 CFR § 180 Agrochemical Tolerances where applicable

    Typical usage ratio

    • 2.0% – 5.5% (w/w) relative to total synthetic mass, fine-tuned for desired aryl substitution in the active ingredient

    Downstream process integration

    • Fed into amidation or nucleophilic substitution stages that generate the critical active core of pre-emergence selective herbicides; followed by isolation and crop-residue testing

    Final product types

    • Selective pre- and post-emergence herbicide actives
    • Formulated crop protection products for cereals and oilseeds
    • Bulk herbicide technicals destined for global agricultural markets

    3. Advanced Material Science—Functional Polymer Additives

    Innovators in material science incorporate this compound as a specialty modifier in fluorinated and brominated polymer networks requiring thermal and chemical resistance. Its controlled electrochemical profile permits covalent grafting onto backbone polymers, supporting applications such as ion-exchange membranes and specialty elastomers targeting harsh industrial processing environments.

    Industry compliance standards

    • ISO 14001 Environmental Management (polymer manufacturing)
    • RoHS Directive 2011/65/EU for restricted substances in electronics polymers
    • UL 94 Flammability standards for plastics
    • ASTM D638 Polymer mechanical property protocols

    Typical usage ratio

    • Trace to 1.2% (w/w) depending on degree of functionalization and target polymer characteristics; empirical adjustment determined by end-use mechanical/thermal property benchmarks

    Downstream process integration

    • Utilized during in-situ polymerization or post-polymer functionalization via covalent attachment to polymer chains, enhancing performance in formulated advanced materials

    Final product types

    • Ion-conductive membranes for chemical process industries
    • Specialty industrial elastomers
    • Advanced coatings and adhesives with halogenated backbones

    4. Specialty Chemical Synthesis for Diagnostic Reagent Manufacturing

    Diagnostic reagent producers employ the compound to introduce fluorobenzylamine groups onto assay or probe molecules, significantly improving specificity and signal stability in analytical detection chemistries. It integrates into the derivatization steps for markers in immunoassays and LC-MS applications where precision and lot-to-lot reproducibility under ISO 13485 are mandatory.

    Industry compliance standards

    • ISO 13485:2016 Medical Devices – Quality Management for IVD reagents
    • USP <1224> Transfer of Analytical Procedures
    • CLSI EP05-A3 Evaluation of Precision Performance of Quantitative Measurement Procedures
    • REACH registration for specialty reagents

    Typical usage ratio

    • Typically 0.05% – 0.8% (w/w) in derivatization stages, with adjustment according to probe density, background interference, and detection method sensitivity

    Downstream process integration

    • Introduced during direct covalent conjugation onto chromogenic or fluorogenic cores, or as a functional handle for assay probe immobilization, before purification and quality release

    Final product types

    • Immunoassay diagnostic kits
    • Fluorescent labeled detection reagents for life sciences
    • LC-MS analytical standards for quantitative bioanalysis
    Free Quote

    Competitive 4-Bromo-2-Fluorobenzylamine Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing 4-Bromo-2-Fluorobenzylamine Hydrochloride: Reliability Meets Precision in Fine Chemicals

    Our Approach to Fine Chemical Manufacturing

    Decades spent making specialty chemicals have taught us this: clean processes and attention to detail deliver the quality research and manufacturing teams need. Over the years, our chemists have learned that quality at the bench translates to reliable results in the lab and on the production floor. Every batch of 4-Bromo-2-Fluorobenzylamine Hydrochloride comes from this attitude. We do not try to be everything for everyone; we focus on what labs and production lines expect—consistent material for challenging projects. Researchers who work with halogenated benzylamines expect more than generic intermediates. That’s why attention to the route, solvent controls, and purification standards matters—each batch reflects this commitment.

    What Sets This Compound Apart

    The fine details in molecules often tell the story. 4-Bromo-2-Fluorobenzylamine Hydrochloride brings together a bromo group and a fluorine atom at the benzylamine core. This simple substitution makes it a crucial building block for synthesis work. The bromine atom at the para position gives chemists flexibility for palladium-catalyzed couplings or nucleophilic displacement reactions—routes that create new possibilities in pharmaceuticals and agrochemicals. The fluorine atom at the ortho position controls electronic properties and may influence metabolic stability when incorporated into drug candidates. No two halogenated benzylamines behave the same way. This compound’s patterning—the bromo and fluoro at 4 and 2—results in properties distinct from typical mono-substituted or other dihalogenated counterparts.

    We do not take short cuts in how we handle or prepare this material. Moisture content, crystalline form, and salt form all matter in downstream reactions. That is why we routinely monitor the hydrochloride salt formation and perform Karl Fischer titrations to keep water levels low. The color and strength of the final hydrochloride are watched batch-by-batch. The salt form translates to reliable solubility in organic and some aqueous solutions; it avoids some storage challenges of the free base.

    Practical Manufacturing Experience

    We learned the hard way early on— halogenated benzylamine precursors sometimes behave unpredictably during bromination or fluorination. Controlling impurities from byproduct isomers, particularly trace amounts of the 3-fluoro or 3-bromo analogs, doesn’t happen by accident. Each lot undergoes targeted purification steps, repeated recrystallizations, and close spectral analysis. We found that the presence of metal residues from catalyst use can spoil downstream reactions, so we adopted robust metal scavenging protocols years ago. The result: clean material without lurking contaminants that can interfere in scale-up or high-throughput screening applications.

    Static charge, hygroscopicity, and dusting posed headaches for packaging—one more way details matter. We choose antistatic liners and check bulk density to prevent clumping, so material dispenses easily in both research and pilot plant settings. Our staff logs each packaging run, and every unit gets a lot-specific certificate with NMR and HPLC traces attached. We believe giving researchers a transparent origin and analytical snapshot leads to fewer surprises at the bench.

    Performance and Versatility

    4-Bromo-2-Fluorobenzylamine Hydrochloride responds predictably in coupling reactions. Catalysis-focused chemists have told us that, compared to 4-bromo alone, this compound delivers smoother reaction kinetics in Suzuki-Miyaura or Buchwald-Hartwig steps, while the ortho fluorine offers a handle when tuning reactivity. Downstream amide coupling with carboxylic acids proceeds efficiently. The hydrochloride salt disperses well in common laboratory solvents such as dichloromethane, ethanol, and even some buffered water-miscible media. We tested this material repeatedly in the preparation of more complex amines, and found that side reactions from uncontrolled iodination or oxidative degradation can be minimized by paying attention to pH and light conditions during handling.

    Our material enables medicinal chemistry teams to test SAR (structure-activity relationship) quickly by providing a reliable, well-characterized scaffold. The combination of bromine for cross-coupling and fluorine for introducing metabolic stability means our 4-Bromo-2-Fluorobenzylamine Hydrochloride supports workflows for modern drug discovery. Synthetic chemists see direct value in substitutions at the amine position, using the hydrochloride salt as a starting point for derivatization. Researchers have reported improved yields compared to similar mono-substituted reagents, especially in cases where electron-rich aromatic rings typically lead to unwanted side products.

    Where This Compound Succeeds—And Why It Matters

    Some customers ask why use this specific combination—why not just a brominated or fluorinated analogue? In our experience, having both halogens provides a rarer set of electronic and steric features in the molecule. This is not only important for making intermediates for pharmaceuticals or crop protection agents, but also for specialty electronic materials where patterning affects downstream properties. Other substituted benzylamines often can’t stand in; their reactivity or stability differs in subtle but crucial ways. Our internal project files include several dozen examples—one transferred to scale-up because the dual halogen pattern avoided aromatic oxidation seen with single-substituent alternatives.

    Over the last five years, we have seen universities and pharmaceutical groups come back for this hydrochloride because it solves real problems at the bench: the crystalline form remains stable through shipping and short-term storage, and the salt avoids unpredictable behavior in scale-up. Minimizing batch-to-batch variation keeps projects moving forward, not on pause while purification issues get sorted out. Field feedback has reinforced our technical strategy to offer this hydrochloride salt rather than just the free base. Our team tracks degradation trends and physical observations to stay out front of stability challenges.

    Transparent Characterization and Oversight

    We take data seriously. Not just as a box-ticking exercise, but as part of our own risk management and pride of manufacture. Every gram ships with a matching lot record. For 4-Bromo-2-Fluorobenzylamine Hydrochloride, we rely on 1H and 19F NMR, as well as LC-MS and HPLC purity by multiple detection channels—not only by UV but also by mass and charged aerosol when relevant. Overlapping signals from closely related impurities receive particular scrutiny. Impurity profiles, water content, and melting points are retained long-term, so if a customer needs to re-run a project down the road, we can quickly compare to historical batches and provide peace of mind about process consistency.

    We saw situations in outsourced production where information about trace metals or minor byproducts disappears through the supply chain. Direct manufacturing means full control and visibility. If a customer asks for data beyond the norm—such as residual palladium, platinum, or silica content—we provide it from the retained samples that follow every production batch.

    Handling and Compatibility Insights From the Plant Floor

    Operating in real manufacturing environments, we learned the quirks that come with halogenated benzylamines. Exposure to ambient humidity, light, and even the type of stirring bar matter for batch success. Our packaging and logistics teams include desiccant and secondary containment based on seasonal climate patterns. We learned that hydroscopic caking can slow down dosing in automated lines, so we keep lot-specific reports on pourability and monitor for static buildup.

    On the chemistry side, effective use of this hydrochloride often depends on gentle warming or controlled-pH workups. In multi-gram and kilogram runs, we observed byproduct dimers appear under harsh basic conditions, so we recommend adding slowly to avoid localized high concentrations. The robust salt form—in contrast to the free base—lets labs avoid rapid discoloration or off-odors, especially during weighing or storage outside the glove box. That reliability has helped several academic partners keep their timelines on track, even during tight grant cycles.

    Real-World Differences: Benchmarking Against Other Benzylamines

    Questions come up about how 4-Bromo-2-Fluorobenzylamine Hydrochloride measures against alternatives. Compared to the 4-bromo or 2-fluoro monosubstituted versions, this compound offers greater synthetic flexibility—chemists can introduce functional handles via the bromine without losing the valuable fluorine. Unsubstituted benzylamines, and even methyl- or chloro-substituted options, can’t match the chemical tunability provided here. We ran parallel reactions with competitor products sourced from traders and third-party brokers. Variations in crystalline quality, batch purity, and impurity profiles—the sort of problems that keep a process chemist up at night—showed up in the most minor details: inconsistent NMR signals, untraceable discoloration, or trace solvents undetected by basic GC. In our product, transparency and control trump the cost-cutting steps found in external repackaging or untracked contract batches.

    We have also seen that matching the crystalline salt form to the needs of downstream chemistry avoids undetected cation exchange problems. For sensitive amination steps or protection group chemistry, starting with a consistent hydrochloride form helps reproducibility in later routes. Our customer files include improved overall synthesis yields of 5–10% on average versus protocols based on alternative free amine or oxalate salts. From a practical standpoint, the tight melting point range and white crystalline appearance give bench chemists confidence in project progress, avoiding delays caused by impurity remediation.

    Support for Innovation: Solutions We Offer

    Supporting customers goes beyond shipping orders. We field questions every month about reaction workups, detection of minor impurities, or even optimizing solvent choices for scale-up. Technical support from our synthesis staff, not just commercial representatives, bridges the gap from raw material to successful end product. We make site visits with pilot plant engineers to advise on mixing, dosing, or filtration steps when bringing our halogenated benzylamines into real-world campaigns. The product’s track record in cross-coupling and amide formation campaigns comes directly from feedback and experimental data, not just chemical theory.

    Material safety is another reality. Our in-house documentation covers reactivity with oxidants, storage guidance, and guidelines for handling under shift conditions. Because we produce every batch in-house, recalls or changes in raw material sourcing receive immediate attention. Drawing on years of continuous manufacturing means if regulatory documentation or export certificates require updating, we react without delay. Complying with REACH, TSCA, or other regulatory standards is not a bolt-on—it's tied into our batch records from day one.

    Looking Forward: Challenges and Sustainable Practices

    Manufacturing fine chemicals, especially halogenated aminobenzenes, brings challenges: waste solvent reduction, safe containment of brominated intermediates, and reducing residual metal catalyst in final product. Our site invests in closed-loop solvent recovery and advanced stepwise purification to minimize environmental impact. A task force inside our process engineering group tracks emissions, water use, and reagent life cycle to support our sustainability goals. Customers increasingly want traceability and data on manufacturing footprint, not just quality. Each improvement, whether it’s swapping to greener solvents or switching to smarter catalyst removal, comes from lessons learned directly on the floor.

    Continuous improvement does not just mean avoiding regulatory headaches. Chemists at our bench are rewarded for identifying ways to streamline, reduce waste, and improve reliability—practices that have a meaningful impact on cost and time-to-lab for our clients as a result.

    Commitment to Continuous Dialogue

    Our years of experience have convinced us: the best products arise from listening. Researchers who use 4-Bromo-2-Fluorobenzylamine Hydrochloride for years help us refine not only how we make it, but how we prepare, test, and deliver it. Their insights about storage, reaction performance, and scale-up headaches shape the changes we make in real time. Open phone lines and plain-talk documentation keep the conversation grounded, always focused on users’ results. For us, success with a demanding intermediate like this does not come from clever advertising or bulk inventory, but from old-fashioned diligence—attending to technical details, responding to data, and building mutual trust across each batch.

    Trusted Source for Critical Synthesis

    Every gram of 4-Bromo-2-Fluorobenzylamine Hydrochloride leaves our factory touched by this level of care. For those who seek confidence in their synthetic tools, this compound stands as a direct result of stable sourcing, deep in-house expertise, and a commitment to transparency at every step. We know chemistry does not forgive shortcuts, and neither do our users. That is why continuous improvement, data-backed assurance, and full process visibility guide everything we do—from raw material vetting to the last detail of the sealed shipment.