|
HS Code |
913130 |
| Productname | 4-Aminoantipyrine Hydrochloride |
| Casnumber | 1147-88-2 |
| Molecularformula | C11H14N3O·HCl |
| Molecularweight | 239.71 g/mol |
| Appearance | White to off-white crystalline powder |
| Solubility | Soluble in water |
| Meltingpoint | 191-193°C (decomposes) |
| Purity | Typically ≥98% |
| Storageconditions | Store at room temperature, keep container tightly closed |
| Synonyms | 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazolin-5-one hydrochloride |
As an accredited 4-Aminoantipyrine Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 250g of 4-Aminoantipyrine Hydrochloride, packed in a tightly sealed amber glass bottle with tamper-evident cap and clear labeling. |
| Shipping | 4-Aminoantipyrine Hydrochloride is shipped in tightly sealed containers, protected from light and moisture to ensure stability. It is packed according to chemical safety regulations, labeled with hazard information, and cushioned to prevent breakage or leaks during transit. Appropriate documentation and handling instructions accompany each shipment for safe and compliant delivery. |
| Storage | 4-Aminoantipyrine Hydrochloride should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from moisture and incompatible substances such as strong oxidizers. Protect from light and heat. Ensure chemical is kept at room temperature and handle using appropriate safety precautions, including personal protective equipment to avoid contact and inhalation. |
Applications of 4-Aminoantipyrine Hydrochloride in Industrial Manufacturing4-Aminoantipyrine Hydrochloride serves as an essential chemical intermediate for several highly specialized downstream industries. Our in-house manufacturing ensures traceability and process control required for demanding industrial environments. The following application scenarios demonstrate its integration in compliant manufacturing systems and finished product lines. 1. Clinical Diagnostics Reagent ProductionMajor diagnostic reagent producers use 4-Aminoantipyrine Hydrochloride for colorimetric assays, including clinical analysis of phenols, peroxides, glucose, and other biochemical markers. The compound reacts with hydrogen peroxide in the presence of peroxidase and substrates, forming quantifiable colored compounds that are critical for accurate, high-throughput blood and serum testing. Consistent purity and batch uniformity remain crucial to ensure test reproducibility and result legitimacy on automated analyzers and point-of-care systems. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Pharmaceutical API Intermediate SynthesisChemical API manufacturers utilize this hydrochloride salt as a multipurpose synthon in the preparation of antipyretic and analgesic drugs. It undergoes further derivatization and condensation reactions to generate diversified active pharmaceutical compounds with strict impurity specifications. Precise molar ratios and reaction controls ensure regulatory compliance and qualification through validated synthetic routes, leading to high-purity pharmaceutical actives for regulated global markets. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Environmental Water Testing Chemical ManufacturingEnvironmental laboratories and specialty reagent providers incorporate this compound in standardized kits for the detection of phenolic compounds and trace oxidants in potable water, wastewater, and industrial discharge. The robust color reaction with 4-Aminoantipyrine, often under alkaline conditions and oxidative catalysts, enables regulatory-compliant monitoring of water quality, ensuring alignment with regional environmental discharge requirements. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Industrial Dyes and Pigments ManufacturingCertain dye and pigment producers employ 4-Aminoantipyrine Hydrochloride as an intermediate in the synthesis of high-performance azo dyes and specialty colorants. The primary aromatic amine group facilitates diazotization and coupling reactions, supporting the creation of lightfast and chemically resistant pigments for demanding textile and industrial coatings markets. Strict feedstock specifications help to minimize downstream impurities and byproduct formation, allowing consistent batch quality and coloration properties. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Analytical Laboratory Reagent SupplyManufacturers of standardized laboratory reagents package 4-Aminoantipyrine Hydrochloride for reference-grade applications in chemical, pharmaceutical, and academic research. The material serves as a key chromogen for colorimetric analysis, titration endpoints, and enzymatic activity assessment. Batch-level traceability and conformance to laboratory reagent chemicals specifications support consistent method validation, calibration, and interlaboratory comparisons. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 4-Aminoantipyrine Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
At our production facility, every batch of 4-Aminoantipyrine Hydrochloride leaves the synthesis line with the unmistakable traits of consistency and purity that chemists count on. After years of refining our reaction, filtration, and crystallization steps, we've reached a point where the staff can trust the product's appearance and analytical values before even peering at the chromatography. The material typically arrives off the filter in a white to off-white crystalline powder, and our regular QC panel—melting point, HPLC purity, and chloride titration—reflects what seasoned process engineers expect. This compound, with the molecular formula C11H13N3O•HCl and a molecular weight just over 241, has developed a reputation on two fronts. First, as a robust reagent in colorimetric analysis, and second, in more specialized applications that demand a reliable source of amino functionalities coupled with the hallmark pyrazolone scaffold.
Every time we produce a batch, the technical team starts with the same strong policy: limit variability, minimize impurities, avoid solvent residues the downstream users will wrestle with. Over the past decade, the process flow has changed in subtle ways—slower addition of the hydrochloric acid to maintain fine control over pH, filtration media selected for least absorption, temperature monitoring at key points to grow the right crystal habit. These hands-on details show up in the final assay and in the way the material behaves in customers' hands.
Routine analysis by NMR and IR ensures structure confirmation, but process engineers watch other details too: washing regimen plays a role in eliminating byproducts like 4-methylaminoantipyrine, while trace metal scans can uncover problems from upstream reagents that slip quality nets elsewhere. We audit every step from raw materials down to packaging, often catching issues invisible at the bench but obvious in kilogram-scale work. It’s this lived-in process oversight that allows our 4-Aminoantipyrine Hydrochloride to consistently reflect purity above 99%, with moisture levels so low researchers rarely bother with extra drying.
Laboratory managers have told our technical team that, when they swapped out an off-the-shelf brand for our product, reaction endpoints sharpened and interference faded in their test protocols. We're not surprised. Reproducibility matters most for analytical purposes—nobody in research or industrial testing wants to be second-guessing baseline drifts or unexplained noise from a reagent bottle. It’s taken years to fine-tune the chain from raw material sourcing through finished product, but that’s the duty of a chemical producer who shares responsibility for the end result.
4-Aminoantipyrine Hydrochloride finds its most established use in analytical chemistry, particularly within phenol detection in water analysis and clinical laboratories. The amine and pyrazolone functionalities allow for rapid and unambiguous color formation, which is the backbone of numerous established enzyme assays and substitution reactions. You’ll see it frequently in peroxidase tests; this compound helps visualize hydrogen peroxide concentrations, acting as a coupling agent with phenolic compounds or similar substrates. Over years of talking shop with laboratory staff, we notice how much they value fast reactions and the avoidance of background coloration.
Because of its solubility in water and most alcohols, 4-Aminoantipyrine Hydrochloride dissolves quickly and allows reactions to run at ambient conditions. The reaction kinetics rarely drift if the temperature holds steady and the stock solution comes from a stable, moisture-protected source. This stability matters not just in individual tests, but during long workdays when procedures must be repeated, and downtime eats into output.
In addition to standard colorimetric work, pharmaceutical process development has started to revisit this compound for intermediate synthesis. The hydrochloride salt, compared to the base form, stores better and handles more predictably in humid environments. This salt formation avoids the flyaway dust and clumping often seen in the free base, which is one reason our staff moved to focus efforts on this grade years ago. Shelf life extends with proper packaging, traceability supports validation, and clean dissolution aligns well with both laboratory and industrial workflows.
Customers often ask what sets 4-Aminoantipyrine Hydrochloride apart from similar compounds: 4-Aminoantipyrine base, 4-Methylantipyrine, and other substituted pyrazolones. Having produced all these at pilot scale or larger, we see firsthand how subtle differences play out in practical use.
First, the hydrochloride’s physical characteristics—crystal habit, flowability, and dusting—make it much less of a handling headache than the base form, which can cake or puff with every bottle opened. The salt form resists atmospheric moisture and reduces static, simplifying weighing and solution prep. On the analytical side, the hydrochloride often shows slightly sharper endpoint colorations and contributes fewer interfering ions in most titrimetric methods. That means less background noise, clearer differentiation of results, and less troubleshooting at the bench.
Some manufacturers lump all aminopyrazolones together, treating each as interchangeable for synthetic or analytical work. Time with each compound shows the opposite. For example, methyl or dimethyl derivatives can carry through different reactivity profiles, sometimes muddying color reactions or failing to dissolve in the same solvents, leading to incomplete reactions or cloudy solutions. The hydrochloride of 4-aminoantipyrine, in contrast, streamlines both the logistics and chemistry of the workflow. QC scientists in our own facility rely on its precision so that process variation remains low and troubleshooting time stays short.
Scaling this compound up from beaker to large glass-lined reactors has not always run smoothly. Early on, minor exothermic spikes during acid addition could lead to heterogeneous crystals that clogged filters and trapped byproducts. Tweaking agitation rates and addition profiles smoothed these rough patches; over time, experience taught the team where each critical control point sat. Even small changes at scale, such as filter pore sizes or switching to closed drying trays, have real impact on the product’s purity.
Moving from open trays to nitrogen-blanketed dryers dropped both the residual moisture and the tendency for slight yellowing, key improvements when pharmaceutical clients started specifying tighter acceptance limits. Operator experience at every phase, from batch charging to final packaging, transformed vague problem-solving into actionable steps. Today, our documentation spells out each of these details, but their origin lay in dozens of product improvement meetings and post-run reviews.
Our specification sheets mirror what we see necessary for repeatable chemistry: purity above 99%, defined melting range, narrow moisture content, and documented absence of specific trace impurities. High iron content, for example, will skew colorimetric assays—so we built an additional test into the release protocol. It’s not about claiming a number on a sheet. Instead, every value carries lessons from chemists and engineers who saw how answers drifted when something slipped.
Physical control matters no less. Particle size influences how the powder disperses. Consistency during drying influences flow from the packaging drum to the end user’s flask. With this compound, lab techs sometimes need to prepare highly dilute solutions; a clumped or partially dried powder dissolves unpredictably and leads to inconsistent results. We keep a close eye on these physical metrics because customers judge us on the reliability of each critical step in their process.
Standard practice calls for tight-seal packaging. In our facility, drums and bottles close immediately after filling, followed by a second check before shipping. Over the years, experience shows exposure to air leads to caking, especially in humid conditions—a problem acutely felt in tropical climates or storage rooms without strong climate control. A double-layer barrier, often with a moisture indicator included for large drums, prevents spoilage during shipment. Logistics staff keep these routines not just for regulatory compliance, but because they’ve seen what happens when shortcuts crop up.
Our procurement staff watches global raw material markets carefully: a bad lot of aniline or over-aged oxidants immediately shows up in product quality. Early experiences, when we relied on less data-driven vendors, burned in the importance of tight supplier controls and routine raw input testing. By keeping in close contact with upstream suppliers, we can spot risks early—whether from geopolitical shifts, logistics delays, or natural disasters. Each finished batch gets tied directly to its input lots, and all analytical data stays archived for auditing or customer review.
Process repeatability remains the foundation of our entire production approach. The most frequent customer praise—and occasionally, critique—relates to lot-to-lot consistency. Any deviation stands out in monthly reviews, triggering root-cause analysis and, when needed, direct communication with affected users. Over time, these measures have protected both our product reputation and customers' confidence that each shipment will match the last.
Technical support from the manufacturer’s perspective goes deeper than answering questions. It starts with a willingness to share process insights. Years of collaboration with academic and industrial partners have taught us that, while specification sheets help, candid conversation about strengths and potential limitations means more. Occasionally, users run into unusual results—cloudy solutions, unexpected reactivity, or challenging precipitation. Most issues trace back either to storage conditions, instrument calibration, or procedural differences. Our technical staff investigates each report, not because it’s a formality, but because manufacturing and research share common ground in the search for reproducibility and improvement.
Practical help comes from deep familiarity with every step, from raw materials to packaging. For customers, our support isn’t just a response—it’s ongoing feedback about process changes, shipping conditions, and ways to head off minor headaches before they grow. We've seen how replacing a mechanical seal or adjusting fill rates makes a difference downstream. This level of backing helps customers get the most from each batch and keeps the feedback loop running, which circles back to quality gains in the manufacturing pipeline.
New applications for 4-Aminoantipyrine Hydrochloride continue emerging, especially as regulation around water quality tightens and pharmaceutical synthesis seeks more robust intermediates. Our R&D staff is always on the lookout for new requests: tighter thresholds for impurities, novel packaging, or form changes that meet next-generation lab needs. Requests from users shape future direction—sometimes leading us to pilot a modified drying sequence, or develop a custom blend for unique instrumentation.
Our ongoing investments in process improvement, environmental controls, and analytical tools have all come from firsthand experience in the plant. Process chemists, operators, and QC specialists guide change, aiming to meet not just regulatory expectations but the sharper standards that working chemists demand. Product stewardship continues beyond the loading dock, shaping better chemistry in labs and factories that depend on sound starting materials. Those of us turning over hundreds of kilograms each year know that every added control, and every tweak, ultimately supports the results you see in your own lab or production floor.
Reliability in 4-Aminoantipyrine Hydrochloride production didn’t arrive through shortcuts. Every specification, every process checkpoint, and every improvement came from trying, failing, adjusting, and doing better. For us, the process is never “done”—each feedback, both in the form of praise and critique, gets filtered back into the next batch. We do not just provide a chemical; we provide the certainty that the chemistry behaves as expected, that analytical baselines hold true, and that each downstream test or synthesis proceeds without hiccups. That's not marketing talk—it's the real story from a manufacturer’s shop floor.