|
HS Code |
266464 |
| Chemical Name | 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate |
| Cas Number | 114545-25-2 |
| Molecular Formula | C11H8N3NaO3·xH2O |
| Molar Mass | 269.20 g/mol (anhydrous basis) |
| Appearance | Red to brown powder |
| Solubility | Soluble in water |
| Melting Point | Decomposes |
| Purity | Typically >98% |
| Storage Temperature | Store at 2-8°C |
| Synonyms | PAR sodium salt hydrate |
| Spectral Properties | λmax ≈ 415 nm (aqueous solution) |
| Hazard Statements | May cause irritation to skin, eyes, and respiratory system |
As an accredited 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | A 25g amber glass bottle labeled "4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate," tightly sealed, with hazard and safety information displayed. |
| Shipping | 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate ships in tightly sealed containers to prevent moisture absorption and contamination. The chemical is classified as non-hazardous, allowing for standard shipping methods. Packaging complies with relevant safety regulations, ensuring secure transit. Store in a cool, dry place upon receipt to maintain product stability. |
| Storage | Store 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area at room temperature. Avoid exposure to heat or incompatible materials such as strong acids and oxidizing agents. Ensure that the storage location is clearly labeled and adheres to standard chemical safety protocols. |
Applications of 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate in Industrial ManufacturingAs an established chemical raw material manufacturer, we provide 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate for specialized industrial use, supporting companies across high-precision analytical, diagnostics, and electronics sectors. The following sections outline real-world downstream scenarios adopting this material, aligned with relevant regulatory, process, and end-use specifics. 1. Analytical Reagent Production for Metal Ion DeterminationOur product finds primary adoption as a colorimetric chelating agent for trace metal analysis, forming the backbone of accurate detection protocols in laboratory, environmental, and process control settings. Laboratories and diagnostics manufacturers leverage its high affinity for metal ions such as zinc, cobalt, nickel, and cadmium in spectrophotometric determination workflows. Stringent control of purity and batch consistency is required, as reagent performance directly impacts analytical reliability and accreditation. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Diagnostic Kit Manufacturing – Clinical ChemistryDiagnostic device companies utilize the material as a chromogenic agent for clinical detection of trace metals in serum, urine, and other biological fluids. Its high molar absorptivity and color development consistency are vital for precise quantification in routine blood work and specialty diagnostics. All formulation batches must meet medical-grade production requirements and trace impurity limits, supporting IVD test kit regulatory submissions. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Water Treatment System Control and MonitoringManufacturers of water quality monitoring devices apply this reagent for on-site and automated testing of heavy metal ions down to low parts-per-billion thresholds, critical for industrial discharge, potable water, and wastewater compliance. Compact and robust formulation ensures stability and shelf-life in both field-based test kits and online monitoring sensors, supporting utility and industrial customers facing regulatory inspection. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Semiconductor and Electronic Component Manufacturing QCFabricators and quality laboratories in the electronics industry employ this material to monitor trace metal contamination during wafer production and component finishing. Low-level detection is critical in controlling process chemical purity, as even microgram contamination can impair final chip or PCB performance. All shipments adhere to semiconductor-grade purity and trace metal impurity profiles. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
5. Research-Grade Colorimetric Sensor Material SupplyAcademic and industrial research laboratories source our product for development of novel colorimetric sensors, responsive films, and detection arrays for multimetal screening and environmental diagnostics. Thin-film deposition, paper-based sensor manufacturing, and microfluidic device assembly rely on accurate and reproducible reagent performance to ensure research data validity. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: admin@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
As a chemical manufacturer with three decades in the industry, we’ve seen how fundamental precision has become, especially when analytical chemists pursue accurate metal ion detection. In the world of complexometric analysis, few reagents match the reliability and selectivity of 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate, often known by its shorthand, PAR sodium salt hydrate. Our focus rests on supplying PAR sodium salt hydrate that supports labs looking for clean, consistent outcomes, not only with every batch but from the very drum in which it ships.
We understand that even minor inconsistencies in a chelating reagent can amplify into major issues downstream, especially for trace metal analysis. Our customers have pushed us to refine every element of synthesis and purification for this compound, aiming for consistent performance in sensitive spectrophotometric tasks. In our facilities, dedicated synthesis lines for chelating dyes such as PAR sodium salt hydrate never share space or solvents with unrelated organics or inorganics. We commit to traceable, contaminant-free supply because a hint of metal or other dye impurity can shift analytical baselines and misguide method validation.
PAR sodium salt hydrate, produced under our standard lot model HBC-205H, offers listed purity in line with analytical requirements — typically above 98%, measured by both titrimetric and HPLC-UV standards. Hydration state receives careful control through low-temperature drying and monitored storage, since even small shifts in water content cause mass weighing errors. Every lot’s certificate carries precise water of hydration percentages alongside trace iron, copper, and other transition metals, since their presence directly influences colorimetric interpretations.
Particle size for our standard offering falls within the 100–200 mesh range by sieving, and our blending line achieves low clump-forming tendencies, which supports fast dissolution in both neutral and weakly acidic aqueous systems. We produce standard packaging for laboratory research in 25 g, 100 g, and 1 kg units. In instances where researchers demand ultra-low metal background, we prepare special microfiltered lots, validated with sub-ppm impurity levels, set aside for critical applications such as advanced environmental monitoring.
Shelf-life concerns have never been trivialized in our plant. While PAR sodium salt hydrate demonstrates decent stability under ambient conditions, we recommend sealed storage away from light and humidity, honoring the compound’s known photofading and hydrolysis pathways. We continually review our packaging barrier films to slow degradation, and plenty of customers thank us for product that keeps performance across years, never just months after supply.
Our production team has supported thousands of applications, but PAR sodium salt hydrate’s most robust user base remains in laboratories tasked with transition metal analysis. This chelating dye binds strongly to many metal cations, such as zinc, lead, cobalt, nickel, and particularly iron. Its use as a colorimetric indicator stretches into soil, water, and biological tissue testing, as well as trace determination in food safety surveys.
PAR sodium salt hydrate in the sodium salt form provides better water solubility than the neutral free base, which cuts down on pre-solubilization time and supports reproducible spike concentrations, especially in buffered or neutral pH ranges. Researchers running UV-Vis spectrophotometry appreciate the reproducible λmax absorbance in the 490–520 nm range and the sharp color change on complexation, which supports both endpoint titration and real-time quantification.
In our collaborations with university research labs, we’ve also assisted in protocols involving titration of both micro and nanomolar concentrations. Examples include tracking free iron in enzyme assays or monitoring trace copper in high-purity water systems for semiconductor manufacturing. The sodium salt hydrate version avoids legacy difficulties associated with slow-dissolving free base or potassium salt analogues, so less time gets spent coaxing the reagent into solution.
Waste stream monitoring relies on these properties. A major customer from the electronics sector leverages our lot-specific purity certificates to validate their process effluent for trace zinc, which falls under local discharge limits. Any unexpected result can often be traced back to batch-to-batch variations, so our plant ties each drum to full digital tracking in our lab information system. That kind of traceability keeps both their audits and ours clean.
4-(2-Pyridylazo)Resorcinol exists in various salt and hydrate forms, with industry and academic users often referencing the free base, potassium salt, and monohydrate/dihydrate modifications. Decades of user reports and technical literature make clear that the sodium salt hydrate version regularly outperforms less soluble or less stable variants. The free base, while still available on the global market, takes longer to dissolve and sometimes precipitates upon dilution, which complicates automated liquid handling.
Comparing purity data, sodium salt hydrate batches from our synthesis route give consistently lower background absorbance in blank runs than those produced by local blending or by traders reprocessing bulk intermediates. In our own in-line QC checks, background absorbance below 0.01 at working concentration typically marks a lot as “analytical grade,” ensuring negligible signal drift. In contrast, potassium salts offered by some other factories have drawn complaints from users who experience contamination from chloride or potassium impurities, which can introduce artifacts when measuring low-concentration ions in urban wastewater or in high-purity environmental surveys.
Admittedly, the sodium salt hydrates carry a slightly higher density and are a touch more hygroscopic than some free base lots. But this cost in storage stability gets outweighed by gains in solubility and lower baseline spectral noise. Sodium ions rarely interfere with typical analytical workflows, while potassium or ammonium analogues sometimes bring unexpected reactivity, especially when users blend with other buffer systems.
Downstream impacts of cleanliness manifest especially in regulated spaces where data from a metal detection workflow feeds into health or safety decision-making. We worked alongside several environmental monitoring agencies, advising them on the transition from less-purified competitive products to our own sodium salt hydrate. The switch generated fewer ambiguous readings in the field, which trimmed both method troubleshooting time and unnecessary sample retesting.
In university classrooms and training labs, where cost pressures dominate, some users have tried to substitute lower-purity analogues intended for industry use. Our technical support often receives calls on dye behavior, and many headaches stem from unlisted impurities in off-brand or repacked lots—opaque trace metals, unknown buffers, or degraded compounds that change solution behavior. We always recommend confirming batch origin and hydration control as cornerstones for reproducible metal determination, because time spent chasing baseline drift soon outweighs any initial savings on "cheaper" lots.
From our position as a manufacturer, we have watched the ripple effects of shifting regulatory standards—especially lower detection limits in environmental monitoring and industrial hygiene. Typical customers once satisfied with detection limits at parts-per-million now ask for credible parts-per-billion or lower, thanks to evolving wastewater regulations and more sensitive instrumentation.
PAR sodium salt hydrate, when produced with low iron and copper backgrounds, can defer or eliminate the need for time-consuming blank subtraction or post-hoc recalibration. Smaller labs without access to costly ultrapure water systems still depend on the incoming dye’s purity as a limiting factor. Our automated synthesis lines, coupled with chelating resin clean-up and multi-stage recrystallization, let us hold metal cation backgrounds under 1 ppm, as verified by mass spectrometry for every lot. Smaller resellers and traders rarely invest in this level of purification infrastructure, whereas our longstanding lab partnerships demand it batch after batch.
In QC and process settings, time saved in prepping clean blanks directly translates to faster sample throughput and more reliable trending. Monitoring shifts in baseline coloration from day to day, particularly in industries that track heavy metal contamination, leaves little room for error. As synthetic chemists, we pay close attention to every step in compound development—from reduction of nitro precursors to the final salt formation and drying cycle. Years ago, we encountered a string of batches where trace manganese carried through the synthesis, discovered only after a round of failed confirmatory tests at a partner lab. Through root cause analysis, we traced and eliminated the contamination at the raw materials point, updated our supplier audits, and responded by implementing online metal screening. That experience set a new standard in our operational controls and built greater trust with our end users.
Scaling production doesn’t mean sacrificing consistency. We have had to grow batch sizes while ensuring every new drum matches traceability protocols set by regulatory clients. Implementing automated online drying, in-line particle screening, and robotic bagging helps keep human error and environmental drift at bay, especially as humidity, batch cycle time, and even local atmospheric pressure vary. We regularly welcome customer-side audits to confirm GMP-grade cleanliness and analytical reliability. Each new customer challenge has driven our plant towards greater transparency and more objective lot validation, whether for environmental, educational, or advanced research use.
Supplying 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate means upholding more than just high-purity compound delivery—it involves supporting the entire analytical pipeline that rests on confidence and reproducibility. For every lot of PAR sodium salt hydrate that leaves our plant, documentation tracks not only certificates of analysis but also recommended storage guidance, references for common buffer recipes, and available technical troubleshooting. Our technical support line sees regular requests about optimal buffer preparations for complex matrix samples, to maximize chelation selectivity and shorten stabilization times.
In cases where new application notes or advances in trace metal analysis methods appear in the literature, our chemical engineers and product development team reach out to both returning and prospective clients with updates and revised guidance on reagent use. In a few recent cases, we have assisted national laboratories in adapting updated methodologies for cobalt or nickel testing, bringing in extra colorimetric absorbance interference testing to match new governmental guidelines.
We carry experience from supporting reagent transitions between batchwise “classical” titrimetry and modern automated flow injection instruments. The sodium salt hydrate form proves robust across both platforms, tolerating short-term temperature swings better than non-hydrated dye lots shipped under less controlled conditions. In solvent selection for dissolution and rinsing, our teams advise sticking with DI or Milli-Q water, avoiding solvent blends that can leave residues or cause slow degradation of the azo chromophore.
Standing as the manufacturer, not an intermediary, puts responsibility squarely on our shoulders to support every data point that emerges from our products. True quality lies not only in hitting a purity target but maintaining consistent lot-to-lot composition and providing the documentation and support needed when end users tackle difficult analytical challenges. Users leveraging PAR sodium salt hydrate in regulated testing, research-grade environmental monitoring, or academic teaching rely on us to minimize—and account for—potential sources of analytical drift or interference.
Our track record continues to earn loyalty from clients who demand both reliability and ready technical support. We routinely test feedback data from laboratory customers to optimize future runs, monitor compounding trends for common questions about solubility or reactivity, and publish supporting datasets verifying ultra-low impurity content. For us, transparency in origin, commitment to metal-free protocols, and ongoing technical engagement are as crucial as the compound’s measured absorbance at 515 nm.
We encourage ongoing dialogue with all who use our 4-(2-Pyridylazo)Resorcinol Monosodium Salt Hydrate, whether for routine classroom experiments or highly sensitive environmental trace metal determinations. If workflow needs change, we’re prepared to refine specifications, packaging, or technical references, always guided by customer input and newest best practices. Maintaining clear traceability and open channels with every research and industrial user upholds the credibility of analytical results and keeps our own production quality advancing.