|
HS Code |
867227 |
| Chemical Name | 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid |
| Common Abbreviation | DEHPS |
| Molecular Formula | C7H17NO6S |
| Molecular Weight | 243.28 g/mol |
| Cas Number | 6706-37-0 |
| Appearance | White crystalline powder |
| Solubility In Water | Highly soluble |
| Pka | 7.6 |
| Buffering Range | 7.0–8.0 |
| Melting Point | 220-225 °C (dec.) |
| Storage Conditions | Store at room temperature, dry and tightly closed |
| Synonyms | DEHPS, HEPES sulfonic acid |
| Usage | Biological buffer |
| Hazard Statements | Non-hazardous under normal handling |
| Density | 1.34 g/cm³ |
As an accredited 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sealed white plastic bottle, labeled with hazard and handling information, containing 500g of 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid. |
| Shipping | This chemical, 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid, is shipped in tightly sealed containers to prevent moisture absorption and contamination. It is handled following standard chemical safety protocols, typically under ambient conditions, and packaged according to national and international regulations for non-hazardous laboratory chemicals. |
| Storage | Store **3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid** in a tightly sealed container, away from moisture, heat, and direct sunlight. Keep in a cool, dry, and well-ventilated area, segregated from incompatible substances such as strong acids and oxidizers. Ensure proper labeling and avoid excessive handling to prevent contamination and degradation of the chemical. |
Applications of 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid in Industrial Manufacturing
1. In Vitro Diagnostic (IVD) Buffer Manufacturing
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Biopharmaceutical Protein Purification & Formulation
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Cell Culture Media & Vaccine Production
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Electrophoresis Buffer Preparation in Life Science Research
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Every manufacturer spends time measuring consistency and reliability in process controls, because trusted outcomes form the backbone of chemical production. 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid, known in many laboratories as bicine sulfonic acid, figures strongly in these efforts—offering a blend of buffer range, solubility, and stability for daily preparative needs. Years of hands-on work show its value wherever biological pH control factors into results.
Traceability begins with raw material quality, and extends to the granulation, particle morphology, and even color that our operators notice in each batch. The acid runs best in well-controlled reactors, favoring a precise approach through the final purification steps. Colorless or faintly off-white powder means we have removed process impurities, and that the buffer’s performance will remain consistent from one batch to the next. Consistency shows up not only in appearance but, most importantly, in the substance’s actual performance in solution. Our own direct batch comparisons confirm that minor details in temperature, agitation, and choice of reagents result in tangible downstream results.
As we handle drums and hoppers, attention moves rapidly between purity and process safety. Most biochemical preparation work calls for 99% or greater purity, with metallic ion content kept within strict specifications—since trace metal contamination can catalyze unwanted redox chemistry or disrupt enzyme activity. At this scale, the approach always balances cost with value. Some can cut corners by dropping specification requirements, but precise biochemistry cannot tolerate trace contamination. We built our purification regime on customer feedback: reports of protein aggregation, weak buffer capacity, and foggy solutions always traced back to overlooked trace ions or incomplete crystallization in upstream steps. Analytically, we use standard HPLC, titrimetry, and elemental analysis for QA, using external labs only for periodic confirmation.
3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid covers an effective buffer range from 7.6 to about 9.0, centering near pH 8.35. That hits the sweet spot for most cell culture and biochemical work, where mild alkaline environments preserve enzymatic and protein structure. The hydroxyethyl side groups, with their hydrogen bonding potential, keep the pKa steady across moderate ionic strengths. We’ve met academic and industrial process customers who compare it to Tris, finding less drift in pH near neutral when optimized; this is not just marketing but a statement borne out by metric data.
Traditional phosphate buffers sometimes struggle with calcium, magnesium, or other divalent cations, forming precipitates and complicating assays. We routinely hear about bicine’s much gentler behavior. Our technical support team has been involved when clients have replaced phosphate successfully, saving them downtime spent cleaning clogged columns or recalibrating HPLC detectors.
Chemical process design always involves tradeoffs. Other buffers—HEPES, MOPS, Tris—approach stability and range differently. We manufacture all of them, and can compare directly. Tris, for example, shows a pKa at about 8.1, but users in redox-heavy systems notice instability and pH fluctuation when temperature or ionic strength swings. Bicine’s extra sulfonic acid and hydroxyethyl arms bring enough hydrophilicity to prevent protein sticking and maintain pH even when sample salt concentrations shift.
In a biological process equipment washdown, we have seen users run both Tris and bicine under similar loads. Bicine leaches less in ultrafiltration and requires less volume to reach ideal buffer strength. Where ionic interference from metals or protein interaction is a challenge, especially at mid-alkaline pH, this product commonly registers among the top user preferences.
Solubility matters more than many realize, especially outside laboratory glassware. This sulfonic acid dissolves quickly in cold water, and creates stable solutions without visible microprecipitate for weeks under refrigeration. We’ve had our own shipping and QA staff test random batches shipped in winter, with consistent results—ease of use, minimal undissolved solids, and rapid restoration to service after shipping.
Production lines focus on batch-to-batch consistency and contamination avoidance. Bicine’s synthetic route makes it relatively simple to keep heavy metals below 5 mg/kg. Ammonium and chloride must stay even lower for use in clinical and diagnostic labs. Electrochemical and chromatographic testing after every batch helps ensure not only short-term solution stability but also year-over-year process reproducibility.
Workers see firsthand the influence of minor process changes on product color and free acid content. We learned early by customer feedback and in-house monitoring that insufficient washing leaves an odor and off-color. Regular equipment maintenance and use of dedicated vessels, rather than shared multi-purpose lines, handles cross-contamination risk.
Each drum or bag leaves with documentation for batch records—not just for regulatory reasons, but so lab managers know each lot traces to specific metrics for contaminants, water content, and actual acid value. This matters in real applications—clinical, protein isolation, and downstream bioprocessing—where even a slight deviation disrupts entire production lines. In the event of questions about trace impurities, our certificate data already matches what most advanced biomanufacturing QA teams check internally.
Outside routine lab work, real process experience shapes our view. In large-volume fermentors, cell culture media, and protein purification runs, operators seek pH buffering that does not create foaming, precipitate, or interfere with downstream detection. We see repeat orders from biotech firms and university projects undertaking larger runs, where consistent solution clarity and zero microbubble formation can make or break a trial.
Diagnostics and immunoassays benefit from this product’s low UV absorbance around 260 and 280 nm, allowing researchers to quantify proteins and nucleic acids without interference. Some buffers, such as TRICINE or HEPES, can cause baseline drift or add chromophoric peaks in high-sensitivity UV assays; bicine provides a cleaner readout. We have observed this in several tests comparing different lots and buffer salts, noting not only performance but a reduction in troubleshooting time for end users.
One notable example comes from affinity chromatography work, where other buffers chelate with nickel or cobalt from IMAC columns, leading to inconsistent protein elution. Bicine’s lack of significant chelating side groups makes it compatible with these column matrices, where alternative buffers such as MOPS and HEPES sometimes underperform. Users tackling complex purification, such as membrane protein extraction or antibody purification, often discover gains in both final purity and process speed from the switch.
For teams focused on cell viability or enzyme assays, avoiding any trace of microbial contamination is an ongoing struggle. Bicine resists microbial growth better than certain carbohydrate-based or non-sulfonic buffers, helping users stretch shelf life and minimize background signal from buffer autodegradation. This comes from direct conversations with our downstream partners, whose quality assurance audits focus on lowest possible background.
Proper handling of bicine begins at the warehouse. Staff appreciate the way tightly sealed drums prevent moisture uptake from the atmosphere—important, as hygroscopicity affects weighing accuracy and shelf stability. Those unfamiliar with its behavior can rest assured: open and reseal as needed, since the acid does not form hard, caked lumps even in high humidity unless severely mishandled. We’ve put this claim to the test, subjecting unmixed samples to days of humid air, and found recovery remains simple.
Batchwise dissolving can proceed straight in tap water for non-critical use, but process engineers in pharma and diagnostics always select high purity water and precise pH titration. Our field teams have observed minor deviations in realized pH when non-standard water sources are used, underscoring the need for calculated addition and careful titration in large tanks. Operators favor clear visual cues—a uniform, faintly viscous solution, free of any filaments or floating debris.
Waste minimization features heavily in all modern process lines. Bicine buffer solutions do not require specialized disposal methods under most local codes, given their low toxicity and biodegradable characteristics. Regular clients have documented this advantage in their safety and compliance records, especially compared to halogenated organic buffers or strong acids.
Many users start with Tris or phosphate buffers out of habit. Bicine extends the working pH range upward, fitting applications where aerobic stability and metal ion compatibility both matter. Our chemistry staff compared redox reactivity and buffer capacity in side-by-side tests, measuring not just theoretical value but pH holding in the presence of common challenges like EDTA, salts, and low-concentration protein suspensions.
Tris buffers display drift as temperature shifts. Any sudden heat pulse or mixing event results in overshoot or dropoff, forcing recalibration. Bicine resists this tendency, holding close to the intended value across a wider band. HEPES and MOPS, both zwitterionic, show higher cost per gram and either a too wide or too narrow pH range. They sometimes present issues with light absorption or color formation after repeated freeze-thaw cycles. Bicine handles cold storage and reconstitution better, retaining both minimal background absorbance and solution stability.
In actual practice, our technical teams see customers return to bicine for multi-run protocols. They learn to trust its absence of foam, clear handling, moderate cost, and minimal interference. Feedback after transition almost always mentions a reduction in runtime cleaning and fewer warning alarms during sensitive instrument operation.
Phosphate and carbonate buffers, often used in analytical chemistry, start to precipitate or react with transition metals—a headache in complex sample work. Bicine holds solutions free of turbidity and keeps them running longer without replacement or re-filtering. As we supply neighboring sectors—cell therapy, veterinary diagnostics, even some environmental water test labs—the preference for easy preparation and consistent performance comes through again and again.
After years of manufacturing practice, we know that materials like bicine do not just buffer pH—they anchor process reliability and enable innovation. Researchers cannot afford prolonged troubleshooting of unknown impurities or variable product forms. Team chemistry, and the desire to innovate and test new protocols, depend on trust: trust that materials will dissolve as expected, perform as advertised, and present no hidden side effects after weeks or months of storage.
Today’s advances, including high-throughput protein work, flow cytometry, or cell-free DNA analysis, depend on background noise never drifting from tested levels. We expect biochemistry to keep trending toward higher throughput, automation, and tighter error controls. Materials like bicine permit this growth—if and only if each drum, pail, or bag matches the last in every measurable respect, from solubility to UV profile. Our in-line monitoring, digital batch records, and full transparency meet this challenge directly.
Feedback from advanced industrial clients has shaped our facilities. We expanded dedicated reactor lines and improved filtration, not to chase trends but to meet identified needs for color, particulate, moisture, and trace metals control. The process runs leaner as a result—lower utilities spend, less waste, fewer batch rejections. This in turn pushes costs down for the client, who can reinvest those gains in project R&D.
Our commitment comes from an understanding of where problems emerge: unknown impurities, struggling with colloidal or protein fouling, costly rework after repeated instability, or regulatory gaps from incomplete records. As we see it, adapting to user-reported problems and maintaining full traceability stands as both business sense and plain responsibility.
Each client request or process challenge arms us with practical feedback—sometimes leading to minor adjustments in drying conditions, packaging, or delivery schedules. Our lab and production staff operate in real time, adapting not after months, but after the very next batch if warranted. It is direct communication, combined with the insights of our technical team on complex chemistry problems, that drives continuous genuine improvement.
There’s no value in chasing perfect marketing phrases. The end result shows up in the hands of the operator, the scientist, or the engineer preparing critical solutions. 3-[N,N-Bis(2-Hydroxyethyl)Amino]-2-Hydroxy-1-Propanesulfonic Acid serves as a day-in, day-out workhorse for labs that insist on accuracy and reliability—and that is the result of hard-won experience, not just specification sheets.