Chengjiang, Yuxi, Yunnan, China sales1@sinochem-nanjing.com
Follow us:

3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate

    • Product Name 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate
    • Alias DAB
    • Einecs 221-382-0
    • Mininmum Order 1 g
    • Factory Site Chengjiang, Yuxi, Yunnan, China
    • Price Inquiry sales1@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    184718

    Chemical Name 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate
    Synonyms DAB, DAB·4HCl·2H2O
    Molecular Formula C12H20Cl4N4O2
    Molecular Weight 360.13 g/mol
    Cas Number 7411-49-6
    Appearance Light brown to beige powder
    Solubility Soluble in water
    Storage Conditions Store at 2-8°C, protect from light
    Purity ≥98% (typically)
    Usage Chromogenic substrate in peroxidase histochemistry
    Melting Point Above 300°C (decomposes)
    Hazard Statements May cause genetic defects; suspected of causing cancer

    As an accredited 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing White, opaque plastic bottle labeled "3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate, 25g," includes hazard symbols and lot number for traceability.
    Shipping 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate is shipped in tightly sealed containers to prevent moisture absorption and contamination. It is typically packed with adequate cushioning and labeled in accordance with chemical safety regulations. The product is handled as a non-hazardous substance, but caution is exercised to avoid dust and exposure during transport.
    Storage 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate should be stored in a tightly sealed container, away from light, moisture, and incompatible materials such as strong oxidizers. Keep it in a cool, dry, and well-ventilated area, preferably at 2-8°C (refrigerated). Ensure proper labeling and store in accordance with all applicable chemical safety regulations and institutional guidelines for hazardous chemicals.
    Application of 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate

    Applications of 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate in Industrial Manufacturing



    3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate, manufactured with strict raw material sourcing and process control, finds established use in specialized industrial fields. Its selectivity and proven performance underpin reliable downstream formulations and product consistency. Below we detail application examples where this material meets clearly defined industry standards, is integrated at precise formulation stages, and enables differentiated finished products.



    1. Immunohistochemical (IHC) Detection Reagents in Diagnostic Laboratories


    In clinical and research diagnostics, this compound functions as a chromogenic substrate for peroxidase-based immunohistochemistry assays, supporting sensitive tissue biomarker detection. Laboratory reagent producers rely on its substrate specificity for crisp, brown end-point staining in formalin-fixed, paraffin-embedded tissue sections, allowing for reproducible diagnostic outcomes in pathology.


    Industry compliance standards



    • ISO 13485:2016 - Medical device quality management systems

    • CLSI IHC23-A2 - Immunohistochemistry Quality Assurance

    • European Pharmacopoeia 10.0 (as applicable for in vitro diagnostic grade reagents)

    • US FDA 21 CFR 820 compliance for device reagents


    Typical usage ratio



    • 0.5–2.0 mg/mL in substrate buffer (acetate or phosphate), adjusted during kit optimization to balance signal strength and background staining per antibody and detection protocol


    Downstream process integration



    • Dissolved freshly into the buffer component during kit assembly, before lyophilization or aseptic liquid filling; substrate and buffer vials filled under cleanroom conditions to prevent contamination


    Final product types



    • IHC chromogen substrate kits

    • Automated slide stainer consumables

    • Histopathology laboratory reagents supporting cancer detection and research



    2. Enzyme Immunoassay (EIA/ELISA) Substrate Kits


    This raw material supports colorimetric signal development in peroxidase-linked immunoassays, where accurate and sensitive measurement of target analytes is critical for clinical or industrial sample testing. Manufacturers select this substrate to deliver distinct end-point color suitable for microplate reader quantitation, maintaining lot-to-lot uniformity vital for regulatory submission and routine testing controls.


    Industry compliance standards



    • ISO 9001:2015 and ISO 13485:2016 quality systems

    • US FDA 21 CFR 820 for IVD components

    • CLSI EP17-A2 guidance for detection capability in clinical assays

    • EU In Vitro Diagnostic Regulation (IVDR) 2017/746


    Typical usage ratio



    • 0.1–1.0 mg/mL in phosphate-citrate or proprietary buffer, with precise concentration tailored by kit developers to optimize optical density and shelf-life as confirmed by stability testing


    Downstream process integration



    • Prepared as a liquid concentrate or ready-to-use solution incorporated during microplate kit assembly; filled alongside antibody and calibrator reagents under controlled environment


    Final product types



    • ELISA color substrate kits (single- and multi-component)

    • Clinical and food safety diagnostic assay kits

    • Point-of-care immunoassay consumables



    3. Oxidative Polymerization Reagents for Electronic Materials Research


    In advanced materials laboratories, this diamine compound serves as an oxidative polymerization agent, enabling researchers to synthesize conductive polybenzimidazole-type polymers. Process engineers utilize this pathway to generate base materials for further modification and fabrication of specialty electronic components, supporting the R&D and pilot production of emerging microelectronic devices.


    Industry compliance standards



    • ISO 9001:2015 for research chemical production

    • RoHS Directive 2011/65/EU (for finished components)

    • REACH Regulation EC 1907/2006 registration & safety data compliance

    • IEC 61340-5-1 for electrostatic control program standard (downstream device usage)


    Typical usage ratio



    • Stoichiometric or slight excess, typically 1–1.2 molar equivalents relative to the co-monomer or oxidant, with process chemist adjustment based on polymer target molecular weight and electrical properties


    Downstream process integration



    • Introduced in step-growth polymerization or oxidative coupling reaction setups under inert atmosphere or controlled acidic conditions, followed by solid-phase recovery and post-polymerization purification


    Final product types



    • Polybenzimidazole (PBI) precursor polymers

    • Experimental flexible electronic substrates

    • Specialty resins for conductive adhesives and coatings



    4. Staining Reagents for Forensic Science and Cytochemistry


    For forensic and cytochemical applications, laboratories utilize this substance as a peroxidase substrate to detect hemoproteins in cell and tissue samples, trace evidence, or specimen slides. The precise and intense color reaction supports unambiguous microscopic analysis, improving casework reliability and documentation quality when comparing biological samples or signatures in legal investigations.


    Industry compliance standards



    • ISO/IEC 17025:2017 - Lab accreditation for testing and calibration

    • SWGMDI Quality Assurance Guidelines for Forensic Biology

    • Scientific Working Group for Histotechnology (S.W.G.H.T) best practices

    • OECD Good Laboratory Practice (GLP) guidelines


    Typical usage ratio



    • 0.5–2.0 mg/mL, typically adjusted according to sample type and intended detection sensitivity, guided by standard operating procedures or court-admissible protocols


    Downstream process integration



    • Prepared fresh and applied during slide staining, after specimen fixation and blocking; excess substrate removed before mounting, with reaction timing strictly controlled to preserve color integrity


    Final product types



    • Forensic histological stain kits

    • Cytochemical reagents for academic and forensic labs

    • Certified test kits for blood residue detection



    5. Diagnostic Chromogens in Biopharmaceutical Quality Control


    Biopharmaceutical QA/QC laboratories incorporate this raw material into test kits for the detection of contamination or cross-reactivity in therapeutic protein production lines. The strong and distinct color produced upon peroxidase reaction ensures reliable monitoring of upstream bioprocessing samples, helping manufacturers meet regulatory expectations on product purity and process validation.


    Industry compliance standards



    • EU GMP Annex 1 for sterile medicinal products

    • ICH Q7 GMP for Active Pharmaceutical Ingredients

    • USP <1223> Validation of Alternative Microbiological Methods

    • ISO 17025:2017 laboratory accreditation


    Typical usage ratio



    • 0.2–1.0 mg/mL in buffered assay matrices; adjusted empirically based on the specificity and background levels associated with therapeutic protein batches and matrix effects


    Downstream process integration



    • Formulated as part of quality control test kits; introduced after product sample incubation, serving in the detection step of chromogenic endpoint assays prior to documentation and release validation


    Final product types



    • GMP-compliant contaminant detection kits

    • Release testing reagents for biopharma manufacturing

    • Batch verification assay components


    Free Quote

    Competitive 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate: Reliable Performance for Diagnostic Laboratories

    A Closer Look at 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate

    In over three decades of specializing in the synthesis and production of fine chemicals, we have identified certain products that prove absolutely essential in advanced scientific and medical applications. Among these, 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate—commonly referred to in research circles as DAB—stands out for its crucial role in immunohistochemistry and diagnostic staining.

    The challenge many laboratories face is not only sourcing high-purity DAB but also ensuring consistent reactivity batch after batch, especially where precise visualization under a microscope determines the outcome of research or clinical diagnosis. Our continuous investment in purification and process control allows us to supply DAB tetrahydrochloride dihydrate with reliably low impurity profiles and reproducible staining qualities—critical parameters confirmed through extensive feedback from core users handling routine pathology or research staining protocols.

    Refining Our DAB: Experience Shapes Every Batch

    We produce our DAB by a carefully monitored process, continually improved in direct response to input from our end-users—ranging from hospital histology technicians to university biologists. Early on, we saw the impact that even slight impurities or inconsistent hydration levels could have on staining background or endpoint clarity. Our reactors and purification lines run with routine checks for iron, heavy metals, and oxidized byproducts that can skew color development or increase background noise.

    Laboratory professionals often mention how our DAB dihydrate crystals dissolve cleanly in their buffers without producing haze or particulate. This comes from refined solvent selection and drying conditions, something most mass-market traders gloss over but anyone using DAB for precise immunoperoxidase localization knows matters. Over many production campaigns, our technical team kept narrowing the quality window, making the batch differences negligible from month to month. Even temperature and humidity in our warehouse receive attention, since DAB’s hydration state can drift if exposed to poor storage conditions.

    Model and Specifications Built for Real-World Results

    Our production processes regularly supply research and clinical grade 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate, focusing on the specifications that labs consistently request—high purity, granular consistency, reliable solubility. Analytical checks on every lot, including HPLC purity, hydration content, and free amine level, deliver the confidence end-users demand. We do not just test the finished product; sampling at each key step of synthesis weeds out variability before it reaches packaging.

    Feedback often comes back to grain size and flow: fine DAB powder is prone to dusting and loss during weighing, so we produce slightly coarser crystals on request for labs with higher-throughput setups. Others find best results with our standard model, which produces even suspension for slide-based applications. Lab staff appreciate that a bottle purchased years ago works with the same staining endpoint as a more recent batch. It comes down to day-to-day familiarity; users build their protocol around products they trust to perform predictably.

    How Our DAB Dihydrate Ends Up in the World's Pathology Labs

    Use cases in real-world labs speak more than any checklist. Researchers developing novel antibody panels reach out for DAB that will give them strong, brown peroxidase staining with minimal background. Hospital pathology units rely on this exact product for confirming patient diagnoses on a daily basis. Some labs trust it for in situ hybridization, combining signal clarity with less cross-reactivity compared to chromogens that generate more background or are prone to overdevelopment.

    Our technical support receives regular updates from users validating lot performance with their in-house controls, often noting that switching sources brought on unwanted variability. Some competitors focus on price and bulk supply, but we hear most often that reliability trumps minor cost savings, particularly for regulated clinical labs. The inclusion of tetrahydrochloride and dihydrate states makes our DAB especially stable for storage and handling compared to anhydrous alternatives; the water of crystallization stabilizes the molecule, reducing oxidation on the shelf.

    What Sets This Product Apart from Other Chromogens

    DAB holds a special place among histological chromogens, primarily because of its well-characterized insoluble brown reaction product. In our experience, attempts to substitute DAB with other substrates—such as AEC or TMB—end with trade-offs in tissue contrast, permanence, or safety. AEC, for example, produces a red color but it dissolves in alcohol, limiting its use in protocols requiring permanent mounting. TMB offers a blue product but struggles with tissue definition under brightfield microscopy.

    Some end-users question why DAB remains so popular given regulatory scrutiny around aromatic amines, but the answer returns to consistent, crystal-clear stains and compatibility with mounting methods. Every round of feedback over the past twenty years confirms that, despite new formulations, DAB-tetrahydrochloride dihydrate most reliably supports interpretation by pathologists. Our production line maintains the ideal hydration level, so the reaction proceeds smoothly, and storage risk never undermines stain reliability. Lower purity, off-hydration, or off-spec DAB can produce uneven staining or oxidation, causing unreliable diagnostic readings—a problem our validation program was specifically built to prevent.

    Supporting the Pathologist’s Critical Role

    Diagnostic accuracy in pathology comes down to what the pathologist sees on the slide. As manufacturers, we receive direct feedback from professionals who become deeply familiar with the nuanced differences between a clean DAB stain and a muddy, off-hue result caused by trace contaminants. Control of starting materials, oxidation inhibitors, and packaging environment all play roles in achieving the uniform brown coloration that is readable at the microscope.

    Unlike traders or brokers who may never see the inside of a bench lab, we see our batches through repeated in-house validation by technicians experienced in immunohistochemical workflows. Our staff keep in touch with users who maintain the same protocols through accreditation audits, ensuring that technical documentation meets changing regulatory requirements. In one instance, a researcher found their negative controls developing background; we traced this to a vendor-supplied DAB with a low-level metal contaminant. Since correcting the lot, we review every incoming raw material for contamination, periodically updating protocols to match customer findings or new instrument sensitivity.

    Supporting high-sensitivity and low-background performance is not a theoretical exercise; it arises through transparent communication and willingness to adapt. We supply order documentation and batch-level analytics, giving labs the traceability needed during external inspections. Technical queries receive support from our manufacturing chemists, not an overseas call center, providing immediate feedback when troubleshooting a difficult protocol.

    Understanding the Broader Impact and Industry Trends

    Within the chemical sector, DAB tetrahydrochloride dihydrate does not command headlines but powers vast diagnostic efforts every day. Market trends fluctuate; newer chromogens rise and fall, but DAB’s role remains anchored by practical experience inside the laboratory. Our team follows emerging trends—such as greater automation, demand for single-use reagents, and tightening regulations on aromatic compounds—adjusting production and compliance policies to buffer our clients from regulatory shocks.

    We accommodate requests for custom packaging and sizes, knowing many hospital labs standardize on single-lot codes to prevent confusion during audits. International shipment requires robust labeling for dangerous goods, along with full export documentation in line with destination country requirements. Our staff work with logistics partners experienced in regulated chemicals, so missed connections and customs holdups do not impact diagnostic support.

    Sustainability, Safety, and Evolving Expectations

    As public consciousness rises around chemical safety, we have actively worked to improve our processes and reduce environmental impact. Modern production lines incorporate closed systems and air treatment to capture dust and vapors—wise investments not only for regulatory compliance but for safeguarding our operators. Waste minimization and proper filtration ensure that batch runoff remains strictly within permitted discharge limits.

    On the user side, we supply detailed safety documentation and handling guidelines specific to our product. Training new laboratory personnel has emerged as a central need, especially with the increasing rotation of junior staff. We produce video guides and written protocols in collaboration with longtime users, reducing in-lab accidents and minimizing hazardous exposure. Peroxidase reaction byproducts can be managed safely when clear information is available.

    Feedback from safety managers encouraged us to adopt tamper-evident and recyclable packaging, and users have responded positively. This focus aligns with growing institutional shifts toward ‘greener’ labs, even where traditional chemistry underpins their critical diagnostics.

    Navigating Bans, Audits, and Industry Shifts

    Our manufacturing role extends well beyond making and shipping product. Legislation shifts periodically, with various regions considering restrictions on aromatic amine derivatives. As a direct producer, we monitor these developments in real time, proactively adjusting production or compliance documentation so clients experience no supply interruptions. Partnering with regulatory consultants, we prepare safety dossiers and risk assessments on schedule, passing this assurance on to end-users conducting their own compliance reviews.

    Auditors increasingly request line-of-sight traceability for chemical provenance, including validated batch records and sourcing transparency. Our process documentation tracks every ingredient used and every analytical result. Clients receive direct access to these records upon request—not boilerplate statements. Direct engagement with regulated hospital labs has taught us the necessity of robust regulatory credentials, but also the benefit of a single point of contact for resolving queries.

    We openly share what chemical intermediates are used and how they are handled, showing that clinging to proprietary secrecy no longer suits the realities of today’s regulated sectors. Maintaining supply in the face of shifting import controls requires not only adaptation to paperwork but also flexibility in procurement and manufacturing. Our laboratory teams meet monthly to review upcoming regulatory milestones, proactively aligning processes before these become a hurdle for our customers.

    Continuous Improvement: Learning from the Field

    Veteran laboratory staff frequently reach out with technical suggestions, sometimes challenging our manufacturing approach. We view these discussions as opportunities to refine product quality and packaging, taking real feedback and looping it directly into development cycles. An example: a pathologist noted subtle differences in stain color after switching to an automated slide-preparation system. In response, we introduced additional downstream purification steps, conducting blind sample tests against standard panels until feedback confirmed the change eliminated staining inconsistencies.

    Through yearly user conferences and continuing education, our chemists remain familiar with evolving best practices outside traditional production domains. This close partnership between field teams and factory chemists has repeatedly led to changes in filtration, drying, and storage parameters, directly improving lot stability and in-use consistency. We also prioritize communication with biomedical engineers and instrument companies as automated stainers become increasingly prevalent; these machines often reveal subtle solvency or interaction issues masked by manual workflows.

    Pushing Forward With Quality and Integrity

    Central to what we do is a commitment to give every laboratory, regardless of size, a dependable supply of 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate that meets exacting standards for diagnostic clarity. We do not cut corners or dilute specification simply to meet cost objections; every bottle reflects the accumulated experience and trust built up over decades of close collaboration with laboratory scientists. Whether supporting a university researcher refining antibody-antigen localization or a hospital technologist confirming patient diagnoses, the product remains synonymous with reliability in chromogenic detection.

    Trust comes from more than words. Every complaint or reported anomaly triggers an investigation, with corrective actions quickly documented and results shared openly with the customer. Tracing a root cause might lead to supplier changes, updated packaging, or even a full batch recall—rare events, but ones that mark a company committed to best practices. Our technical literature reflects contributions from experienced chemists and real end-users, always clear about the capabilities and genuine limitations of DAB tetrahydrochloride dihydrate.

    As the industry moves forward—whether through automation, demands for new detection methods, or regulatory tightening—we remain flexible, transparent, and focused on the needs of scientists and clinicians. The privilege of producing a reagent that underpins critical diagnostic outcomes is not taken for granted. Each new challenge or requirement helps our manufacturing team improve safety, product quality, and end-user support.

    Your Results, Our Reputation

    Every tube, bottle, or drum of our DAB leaves our facility with the certainty that it will help someone, somewhere, see what they need to see—whether for the next journal submission or the next patient result. The compound’s stable dihydrate form, granular flow, and high analytical purity are only possible through discipline in production, attentive listening to real user feedback, and a steadfast refusal to compromise on quality.

    We provide 3,3'-Diaminobenzidine Tetrahydrochloride Dihydrate not as a mere commodity, but as a result of years of hard-won expertise. Our focus stays on what matters: supporting those dedicating their work to insight and discovery under the microscope, meeting every new requirement with earnest craft and hard-won knowhow.