Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing admin@sinochem-nanjing.com 3389378665@qq.com
Follow us:

2-Naphthyl Phosphate Monosodium Salt

    • Product Name 2-Naphthyl Phosphate Monosodium Salt
    • Alias 2-Naphthyl phosphate sodium salt
    • Einecs 242-474-6
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    674087

    Product Name 2-Naphthyl Phosphate Monosodium Salt
    Cas Number 2581-60-2
    Molecular Formula C10H8NaO4P
    Molecular Weight 246.13 g/mol
    Appearance White to off-white powder
    Solubility Soluble in water
    Storage Temperature 2-8°C
    Ph Of 1 Percent Solution 5.0 - 7.0
    Ec Number 219-943-6
    Synonyms Sodium 2-naphthyl phosphate, 2-Naphthylphosphoric acid monosodium salt
    Purity ≥98%
    Hazard Statements Irritant
    Application Chromogenic substrate for phosphatase assays
    Shelf Life 2 years

    As an accredited 2-Naphthyl Phosphate Monosodium Salt factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 2-Naphthyl Phosphate Monosodium Salt is supplied in a sealed 25-gram amber glass bottle, labeled with product details and safety information.
    Shipping 2-Naphthyl Phosphate Monosodium Salt is shipped in tightly sealed, chemical-resistant containers to prevent moisture and contamination. It should be handled with care and stored in a cool, dry place. Compliance with relevant chemical transport regulations is ensured, and appropriate labeling and documentation accompany each shipment for safe and secure delivery.
    Storage 2-Naphthyl Phosphate Monosodium Salt should be stored in a tightly closed container, away from direct sunlight, moisture, and sources of heat. Keep it in a cool, dry, and well-ventilated area, ideally at room temperature (15–25°C). Avoid contact with incompatible substances such as strong oxidizing agents. Ensure appropriate labelling and follow all relevant safety guidelines for handling chemicals.
    Application of 2-Naphthyl Phosphate Monosodium Salt

    Applications of 2-Naphthyl Phosphate Monosodium Salt in Industrial Manufacturing

    2-Naphthyl Phosphate Monosodium Salt serves as a specialized organophosphate substrate, meeting precise requirements in selected biochemical, diagnostic, water analysis, and histochemical manufacturing. As the direct manufacturer, we support global B2B clients in regulated industries with reliable, batch-consistent raw materials that conform to critical process and end-product demands.

    1. Clinical Diagnostic Kit Manufacturing: Enzyme-Linked Immunoassays (ELISA Substrate)

    Diagnostic kit producers formulate enzyme-linked immunoassays with this compound as an effective phosphate-based chromogenic substrate for alkaline phosphatase (AP) detection. It provides high signal clarity and low background, ensuring accurate quantification in clinical biomarker analyses, prenatal screening, therapeutic drug monitoring, and infectious disease tests.

    Industry compliance standards

    • IVDR (EU) 2017/746 for in vitro diagnostic medical devices
    • ISO 13485:2016 – Medical Devices Quality Management Systems
    • United States Pharmacopeia (USP) for analytical reagents
    • 21 CFR Part 820 (FDA QSR)

    Typical usage ratio

    • 0.5–2.5 mg/mL in substrate buffer; adjusted based on required assay sensitivity, AP concentration, and plate or strip format

    Downstream process integration

    • Added directly to substrate buffer preparation during formulation phase
    • Blended under controlled temperature and pH before dispensing into diagnostic wells, plates, or tubes

    Final product types

    • Ready-to-use and concentrated ELISA substrate solutions
    • Packed immunoenzymatic kits for clinical laboratories
    • Point-of-care diagnostic reagent cassettes

    2. Clinical Histochemistry and Pathology Reagents

    Pathology reagent manufacturers use this phosphate ester as a selective chromogenic substrate for localizing alkaline phosphatase activity in fixed tissue and cytology slides. Its stable performance in substrate buffer systems provides clear, permanent staining for the microscopic differentiation of tissue types and pathological structures during disease diagnosis.

    Industry compliance standards

    • CLSI GP42 – Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens
    • ISO 15189:2022 – Medical Laboratories Quality Standard
    • CAP Accreditation Checklist (Histology / Cytology Reagents)
    • Good Laboratory Practice (GLP) requirements

    Typical usage ratio

    • Typically 1–2 mg/mL in buffered saline solution; concentration selected to balance staining time and intensity based on tissue type and protocol

    Downstream process integration

    • Dissolved and filtered into buffered substrate solution during production batching
    • Filled into reagent bottles or ready-to-use histochemical staining sets after stringent QC checks

    Final product types

    • Alkaline phosphatase histochemistry staining kits for hospital pathology labs
    • Automated tissue staining system reagents
    • Specialized cytology staining consumables

    3. Biochemical Research Reagent Production

    Producers of research-grade reagents rely on this salt as a non-radioactive chromogenic substrate for phosphatase enzyme assays in academic and pharmaceutical laboratories. It delivers high sensitivity and reproducibility needed for kinetic studies, enzyme screening, and characterization, supporting research into phosphorylation pathways and enzyme inhibitors.

    Industry compliance standards

    • ISO 9001:2015 – Quality Management System for research reagents
    • REACH Regulation (EC No. 1907/2006) where applicable
    • Good Manufacturing Practice (GMP) for laboratory chemicals (as applicable)
    • Lot-to-lot traceability and Certificate of Analysis (COA) per research reagent supply chain protocols

    Typical usage ratio

    • 0.1–1.0 mg/mL in enzyme assay buffers; adjusted according to target enzyme activity, plate format (96-well, 384-well), and detection wavelength

    Downstream process integration

    • Added during bulk reagent preparation then aliquoted into single-use vials or bulk packs
    • Quality tested for purity, degradation, and background absorbance before shipment

    Final product types

    • Enzyme assay substrate kits for university and R&D lab use
    • Bulk packs of chromogenic AP substrate reagents for high-throughput screening

    4. Water Quality Enzymatic Test Kit Manufacturing

    Manufacturers in the environmental monitoring sector utilize this phosphate ester in enzymatic colorimetric test kits that monitor alkaline phosphatase activity as a water quality indicator. Its stable physicochemical profile facilitates accurate field and laboratory determination of nutrient status and pollution levels in surface and wastewater analysis.

    Industry compliance standards

    • ISO 17378-2:2014 – Determination of organophosphorus compounds in water (laboratory and field test kits)
    • Standard Methods for the Examination of Water and Wastewater (APHA/AWWA/WEF)
    • EN ISO/IEC 17025 – Testing and calibration laboratories accreditation
    • OECD Good Laboratory Practice Guidelines

    Typical usage ratio

    • 0.2–1.5 mg/mL in reaction buffer; precise amount set by sensitivity required for low-level nutrient detection and matrix effect compensation

    Downstream process integration

    • Incorporated into single or multi-vial reagent sets during automated kit filling operations
    • Batched with stabilizers and color indicators for extended shelf-life and consistent test performance under variable field conditions

    Final product types

    • Packaged enzymatic water test kits for environmental field monitoring
    • Portable colorimetric water quality analyzers for laboratory and on-site use
    • Pre-measured test vials for rapid water and wastewater screening
    Free Quote

    Competitive 2-Naphthyl Phosphate Monosodium Salt prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: admin@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    2-Naphthyl Phosphate Monosodium Salt: From Production Floor to Practical Application

    Our Perspective as the Manufacturer

    Walking through our production suites, the importance of precision in creating 2-Naphthyl Phosphate Monosodium Salt (2-NPMS) stands out every single day. Over the years in the business, we have shaped and refined this process to a steady, reliable standard, always guided by practical feedback from real users in the field: researchers probing enzymatic kinetics, analysts developing diagnostic kits, and laboratories teaching the next generation of scientists. Understanding what this product does and what makes it different from others starts before the chemical leaves our reactors.

    Practical Overview and Model Consistency

    2-Naphthyl Phosphate Monosodium Salt does not simply arrive as a powder by chance. Each batch follows deliberate methodology, starting with the careful selection of 2-naphthol and progressing stepwise through controlled phosphorylation and purification. The model, usually referenced as pure grade or AR grade, comes from extensive monitoring—tight controls on temperature, pH, and reagent purity. Batch records, meticulously kept, let us trace outcomes and investigate issues quickly if they arise. Most research and industrial users notice a high degree of consistency in purity, solubility, and reactivity compared to rival offerings precisely because we pay attention to source reactants and remove extraneous sodium chloride, residual solvents, or unreacted starting compounds.

    Specifications that Matter in the Real World

    Clients often ask about the necessity of certain specification values, such as purity exceeding 98%, moisture content under 1%, or strict control over heavy metal contamination. Years of lab requests and process evaluations have proven the value of these thresholds. High-purity 2-Naphthyl Phosphate Monosodium Salt minimizes background interference during colorimetric and fluorometric assays. Moisture levels, though easily influenced by atmospheric conditions, directly affect handling and shelf life. Oversights in drying techniques or packaging integrity always translate to frustration for the user—caked powders, reduced reactivity, or variable assay results. This has led us to invest in robust desiccation protocols and modify packaging practices, so that each delivery meets or exceeds advertised expectations. Since trace heavy metals can deactivate sensitive phosphatases, in-house analysis, using ICP-OES, helps us routinely catch sources of contamination long before shipping.

    Contrast with Similar Phosphate Substrates

    On the surface, phosphate esters can seem interchangeable, but experience shows clear performance differences. 2-Naphthyl Phosphate Monosodium Salt often gets compared with p-Nitrophenyl Phosphate or 4-Methylumbelliferyl Phosphate. The selection typically ties back to the detection system—colorimetric versus fluorometric—or the nature of the enzymes investigated. 2-NPMS, after enzymatic hydrolysis, releases 2-naphthol. This product offers a noticeable pink or purple color on oxidation, providing a reliable signal in enzyme activity assays, even in relatively turbid samples. Researchers working in plant or food extracts usually tell us that the background noise from inherent sample color blocks out more subtle signals from p-Nitrophenyl Phosphate detection. In these cases, 2-Naphthyl systems frequently outperform by a wide margin.

    Another real-world factor comes down to signal stability and handling during endpoint measurements. p-Nitrophenol, for example, can show shifting background depending on assay matrix, necessitating a precise pH adjustment to develop the color fully. Our 2-Naphthyl phosphate substrate allows for more forgiving readout protocols. Adopting this approach has helped more than a few laboratories cut the number of repeat assays, simplifying data analysis.

    Everyday Usage and End-User Experience

    From manufacturing, we watch this product head out in bulk to assay kit producers, university teaching labs, and biotech startups. We hear directly from customers about daily practices that do or don't save time. Commonly, end users dissolve 2-Naphthyl Phosphate Monosodium Salt in buffered solutions for use as an artificial substrate for phosphatases, like alkaline phosphatase or acid phosphatase. The ease of powder dissolution, absence of undissolved particulates, and predictable performance, even from the first to last gram in a bottle, count as practical markers of quality.

    Our team has spent years fielding reports from lab technicians frustrated by sluggish substrate dissolution and the dreaded “sticky film” left after reconstitution in substandard products. To resolve this, drying and milling protocols underwent significant changes. In particular, using low-shear mixing and fine sieving after the drying stage both increased surface area and prevented powder clumping, letting users scoop out precise amounts with minimal dust or waste.

    One overlooked benefit appears in enzyme kinetic studies that require steady signal development over time or larger volumes. We’ve seen 2-NPMS batches prepared under unstable drying conditions fail in long-run assays, generating extra noise or drift in absorbance signals. Shipping out a product which dissolves quickly and reacts predictably has chipped away at researcher frustration, letting the actual experimental variables—not the substrate source—be the main focus.

    Consistent Performance in Diagnostic and Research Applications

    Diagnostic kit formulators speak directly to the pain points that arise when components differ from one lot to the next. Poorly controlled batches risk entire kit recalls; subtle formulation changes can gradually erode customer trust. Through the years, our batch-to-batch documentation, coupled with off-line analytical verification, has given assay developers the steady standard they need for reliable results. Procedures start with the pure substrate, which, upon hydrolysis by specific phosphatases, liberates 2-naphthol—subsequently oxidized by Fast Red TR or similar diazonium salts to generate a dramatic color that technicians can easily recognize, even by eye.

    In research use, especially with tissue sections or cell smears, clear color contrast and clean background signals matter. Pathology labs use 2-NPMS substrates in enzyme histochemistry to highlight structures that would otherwise escape detection. Weak background color, blurred transitions, or inconsistent signal appearance point back to substrate inconsistencies—something we continually work to eliminate at source. Purity checks, controlled granularity, and direct customer feedback loops remain central to our operation.

    Limitations and How We Address Them

    Every chemical has its quirks. 2-Naphthyl Phosphate Monosodium Salt, for instance, reacts to humidity level shifts, especially once the packaging seal is broken. Moisture not only affects handling; it can start to degrade active material if left unchecked. In practice, we doubled down on vacuum-sealed, light-blocking containers and reinforced the recommendation for desiccant storage at user laboratories. Laboratories with especially humid environments reported difficulties keeping the powder free-flowing—extra care in setting up packaging lines and adding indicator sachets has lessened product loss over time.

    Transport and storage temperatures also rank high on customer lists. Shipping through regions with fluctuating climates, we introduced thermal insulation and monitored test shipments over summer and winter. Data loggers within shipping containers told the real story; adjusting packaging to these conditions made a tangible reduction in clumping and color loss.

    While rare, cross-contamination during large-scale production can lead to off-color powders or minor shifts in chemical integrity. We introduced separate weighing areas for critical ingredients and staged “hold” protocols on suspect lots until full testing finished. Smaller, more frequent batches gave us more opportunities to fine-tune the process or catch deviations before stockpiling faulty material.

    Why Users Choose Our Product Over Others

    Conversations with buyers, especially those supporting regulated diagnostics production or therapeutic development, trace their purchasing decisions back to reliability. Our customers recount times where competitors’ lots produced variable color development, or unstable blanks. Some laboratories shift entirely to 2-Naphthyl Phosphate Monosodium Salt for years, citing smoother workflow and sharper endpoint discrimination.

    A research group focused on environmental monitoring once highlighted how sample complexity would mask nitrophenol-derived color, making 2-naphthol-based detection essential. Years of steady repeat business built on that particular, down-to-earth finding. Each such story reminds us that bulk analytical data, while important, does not alone drive repeat orders—it’s the real difference in the lab that counts.

    Trusted Quality Stemming from Long-term Practice

    Looking back at the evolution in production, the shift from manual crystallization to semi-automated reactors and closed-loop pH control marked notable advances. Alongside technical improvements, we focused heavily on documentation. Not just regulatory checklists, but recording operator observations—color or texture shifts, changes in drying rate, or early hints of process drift. This trove of experience offers the base for continuous refinement, and helps answer user questions beyond simply quoting a certificate of analysis. Familiarity with the quirks of 2-NPMS means we can help customers navigate troubleshooting in real-world assays, sometimes providing guidance on storage or preparation that prevents waste.

    Every product batch, supported by detailed test records and certification, reflects years of feedback from routine hospital use, university laboratories, and process R&D teams. Feedback from users has shaped even subtle improvements—such as bottle neck diameter, choice of desiccant, or inner lining materials. Nothing goes unnoticed once it hits our shipping desk, and nothing stays unimproved for long.

    Market Trends and Why Demanding Users Prefer 2-Naphthyl Systems

    In recent years, assay sensitivity requirements have climbed, especially for environmental, food safety, and clinical diagnostics. 2-Naphthyl-based substrates, especially the monosodium salt, have found renewed favor. Their longer shelf life, robust color development, and tolerance for complex sample backgrounds mean fewer failed runs and less time troubleshooting off-target results.

    Regulatory compliance in the IVD sector translates directly into pressure for tighter quality control upstream. To that end, our analytical team regularly audits both internal test protocols and third-party data to ensure we meet market demands. Technical breakthroughs in other enzyme-substrate formats, including luminescent and photometric methods, exist, but the simple visual readout from a 2-Naphthyl system offers enduring appeal. Technicians can spot an error instantly, without needing to re-run the analysis using costly, specialized readers. Clear, immediate results remain powerful advantages decades after this chemistry was first introduced.

    Learning from Real-World Failures and Course Corrections

    As a manufacturer, we take immediate notice when a product fails to meet expectations. Over the years, a handful of product recalls and client complaints shed light on weak process links—anything from uneven drying to drafting issues with raw material suppliers. Each event prompted honest root-cause investigation, adjustment of training for new operators, and equipment upgrades where necessary. One notable project addressed iron trace levels coming from a batch of reaction vessels, with surface treatment and regular monitoring implemented as standard practice thereafter. Such corrections, while sometimes costly in the short term, prevent repeat problems and increase trust over time.

    Failure is a built-in part of manufacturing, but accountability and openness with clients separates long-term success from short-tenure players. Most of our end-users, from academic research coordinators to production-scale assay formulators, value a straightforward answer and a willingness to fix issues more than a hands-off, unsupportive supplier. Our product and approach aim to put these principles into daily practice.

    Forward Outlook: Supporting Future Research & Industry Needs

    The landscape continues to shift as analysis moves from basic enzymology toward advanced biotechnology, point-of-care testing, and automated workflows. 2-Naphthyl Phosphate Monosodium Salt maintains its position due to proven performance, as well as adaptability to newer detection systems. Automation in the lab counts on reliable reagents that do not clog pipette tips, dissolve predictably, and deliver robust color readouts. Since our own team interfaces regularly with kit designers and high-throughput screening specialists, we shape each fresh batch to accommodate these rising expectations.

    Longer shelf life and greater resistance to humidity support growth into regions with less optimal storage infrastructure. For emerging markets and field research locations, chemical resilience is more than a luxury—it becomes necessity. 2-Naphthyl systems, due to their chemical structure, handle these pressures well. Still, we keep searching for packaging advances and drying techniques that preserve reactivity right to the last milligram.

    Concluding Observations from the Factory Floor

    Spending every working day with 2-Naphthyl Phosphate Monosodium Salt, our knowledge is rooted in lived reality, not theory. Smoothing out a powder’s flow with real, tactile changes, running split-batch tests to examine reactivity over time, investing in user-friendly packaging—these practices shape product performance more than a simple data sheet can show. We take pride in delivering a chemical that, lot after lot, keeps biotechnologists, diagnostic teams, and teaching laboratories moving quickly from sample setup to clean, readable results.

    We do not see our work as simply filling a catalog slot. Each improvement approaches not just chemical purity, but predictability, stability, and a real partnership with the user. The practical value of 2-Naphthyl Phosphate Monosodium Salt shines because it’s built on this foundation of experience and honest feedback. And while technologies evolve, the commitment to real-world utility always guides us, from reactor to laboratory bench.