|
HS Code |
433034 |
| Chemical Name | 2',7'-Dichlorofluorescein |
| Cas Number | 76-54-0 |
| Molecular Formula | C20H10Cl2O5 |
| Molecular Weight | 401.20 g/mol |
| Appearance | Yellow to orange powder |
| Melting Point | 305-309 °C |
| Solubility | Slightly soluble in water, soluble in ethanol and DMSO |
| Purity | Typically ≥98% |
| Absorption Maximum | 502 nm (in aqueous solution) |
| Storage Conditions | Store at room temperature, away from light |
| Synonyms | 2',7'-Dichlorofluorescein; DCF |
| Ec Number | 200-968-7 |
As an accredited 2',7'-Dichlorofluorescein factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 25g bottle of 2',7'-Dichlorofluorescein comes in an amber glass container with a secure screw cap and labeled. |
| Shipping | 2',7'-Dichlorofluorescein is shipped in tightly sealed containers, protected from light and moisture. The chemical is typically packaged according to hazardous material regulations, including proper labeling and documentation for safe transport. Standard shipping involves temperature control and compliance with local, national, and international chemical shipping guidelines to ensure safe delivery. |
| Storage | 2',7'-Dichlorofluorescein should be stored in a tightly sealed container, protected from light, moisture, and incompatible substances. Keep the chemical in a cool, dry, well-ventilated area, away from sources of ignition and strong oxidizing agents. Ensure the storage area is clearly labeled and complies with relevant chemical safety regulations to avoid contamination or degradation. |
Applications of 2',7'-Dichlorofluorescein in Industrial ManufacturingAs an established producer, we supply 2',7'-Dichlorofluorescein for specialized uses in chemicals, diagnostics, environmental testing, and biotechnology. Its unique characteristics and regulatory status enable precise integration into advanced manufacturing streams across select industries. 1. Analytical Reagent Manufacturing for Laboratory Use2',7'-Dichlorofluorescein serves as a highly sensitive indicator and tracer for titrimetric analysis, particularly in quantitative detection of precious metals such as silver and mercury in laboratory settings. Producers incorporate it during the formulation of laboratory-grade analytical reagents, using carefully controlled environments to minimize cross-contamination and preserve fluorescent properties. Manufacturers perform thorough purity checks, ensuring the final reagent provides accurate colorimetric change and stable performance under authorized test protocols. The chemical structure delivers stable fluorescence and clear endpoints, which enhances repeatability in quantification workflows. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Environmental Water Analysis Kits2',7'-Dichlorofluorescein is widely used in environmental analysis as a fluorescent tracer for leak detection, water flow studies, and contaminant tracing. Manufacturers formulate this compound into water-soluble tracer tablets or liquid kits, ensuring consistent performance in field applications. Rigid batch controls and validated cleaning of production lines prevent interference from other fluorescent dyes. The substance’s distinctive fluorescence under UV or visible light allows downstream customers to trace water movement and identify leaks in municipal or industrial systems. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Biotechnological Cell Viability Assay KitsBiotechnology manufacturers utilize 2',7'-Dichlorofluorescein as a precursor for 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA), a pivotal fluorogenic probe in measuring cellular oxidative stress and reactive oxygen species. Production involves precise chemical derivatization under GMP guidelines, followed by comprehensive purity and cytotoxicity assessments. Downstream integration calls for strict avoidance of microbial load and contaminant residues to produce reliable cell-based assay kits for research and clinical diagnostics. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Industrial Ink and Marker FormulationSeveral ink and marker manufacturers use 2',7'-Dichlorofluorescein to produce high-visibility security inks, anti-counterfeiting markers, and specialty highlighting products. During pigment and dye blending, operators maintain stringent controls on solubility and brightness, fine-tuning pH and solvent combinations to stabilize color under operational temperature and light conditions. Quality monitoring ensures compliance regarding migration, emission, and user safety in line with occupational health regulations for writing instruments. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 2',7'-Dichlorofluorescein prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
For years, 2',7'-Dichlorofluorescein has played a meaningful role in our laboratory and production lines. We approach its synthesis with an understanding grounded in both science and craft. This compound, known for its vivid green fluorescence, emerges from careful control over chlorination and condensation steps, with every minor variation in reaction conditions leading to differences in yield, purity, and optical clarity. The core model typically refers to the non-sodium free acid—its formula traced to C20H10Cl2O5. Our reactors run batch after batch at scale, and we've seen how solvent choice, temperature accuracy, and pH adjustment influence the color intensity and reactivity of every lot.
What sets production apart for us is a focus on minimizing byproducts like 2’,5’-isomers or excessive hydrolysis. Each run brings slight variables, so real-time monitoring during drying and crystallization ensures consistent pigment strength. This approach matters more than standard specification sheets let on. Our senior chemists still examine the slight off-yellow shade of crude product before purification, a color hinting at byproduct content and overall lot performance. Our site processes even factor in local temperature and humidity swings, which, though sometimes overlooked, interfere with both crystal recovery and storage stability.
Laboratories depend on 2',7'-Dichlorofluorescein for its reliability as an indicator in argentometric titrations, particularly in the Fajans method for chloride determination. The indicator must deliver sharply defined color changes right at the endpoint, so we always check for trace metallic contaminants and excess acid residues during our in-process testing. Tiny differences in purity shift detection thresholds, leading to frustration during titrations. Our batches average higher purity than the broader market, commonly testing >99% by HPLC, helping analysts avoid ghost peaks or background color drifts that obscure data.
The pre-weighed single-use packs we have started producing responded to feedback from busy labs tired of inconsistent manual dispensing. Smaller variations in acid strength or moisture content from conventional bulk material had a way of changing titration results in subtle ways. So we set out to standardize pre-dried material in carefully controlled humidity rooms. These efforts resulted in packs that last through dozens of titrations in a row, and our customers have told us the difference shows up right in the first week of use.
Spectroscopy forms the backbone of fluorescence-based measurements in biology and environmental analysis. With 2',7'-Dichlorofluorescein, spectral purity and photostability rule the day. Our photometric standards rest on the evidence of sharper emission peaks and clean baseline fluorescence. Impurities, such as trace acid chlorides or polychlorinated intermediates, lower sensitivity or cross-react with target analytes. In our facility, each lot undergoes UV-Vis and spectrofluorometric scans, not just for batch certification but as operational routine—if the emission spectrum broadens or shifts even a few nanometers, this tells us something about upstream process drift, and we correct before the next synthesis run.
Discussions with research partners revealed issues with commercial indicators from inconsistent suppliers: high background noise, premature photobleaching, solvent compatibility problems. Our technical staff compared our own material, side-by-side, under identical assay conditions. Results from protein labeling and cell-tracking work demonstrated that our indicator sustained intensity through multiple excitation cycles. This reliability matters in time-course imaging studies where fluctuations translate into faulty biological conclusions.
Our technical service team hears from everyone—analytical labs, universities, wastewater plants. A clinical diagnostics group flagged slow solubility and a slightly orange tinge in material supplied by third parties. Their feedback went straight into our process adjustments. Using extended recrystallization cycles and refining our mother liquor recovery steps eliminated colored byproduct carryover, which had been traceable back to early-phase chlorination variability. By tightening oversight here, dissolution became rapid and solutions cleared up visually, even at high stock concentrations.
On another end, environmental labs shared concerns about toxic trace contaminants—some dichlorinated compounds pose regulatory complications. Our facility developed and validated a secondary chromatographic step, which reduced byproduct levels below existing environmental safety thresholds. The waste stream from our process routes to targeted solvent recovery and neutralization systems—not a trivial investment, but it keeps our operation ahead of local and international requirements, and reduces batch rejection risk on the customer end.
Many labs consider Eriochrome Black T, Phenolphthalein, or even fluorescein sodium—each serves different endpoints in titrations, fluorescence assays, or visualization. Our experience manufacturing 2',7'-Dichlorofluorescein puts us in a position to see its unique behavior in actual use. Compared to standard fluorescein, the dichloro variant resists photodegradation more stubbornly. This translates into less fading under intense UV exposure. In analytical titrations, it anchors the endpoint more distinctly, offering a clear shift rather than a gradual change. Our experience shows that in chlorine-rich matrices, phenolphthalein and other classic indicators sometimes fail to offer a defined transition.
Structural analogs with bromine or different halogen substitutions often cost more and don't necessarily deliver improved spectral clarity for typical biological or analytical work. Over years of head-to-head performance testing in our QC labs, 2',7'-Dichlorofluorescein keeps demonstrating more predictable results in metal ion detection, environmental sample monitoring, and cell biology imaging. Our own QC staff choose to run validation checks with it as a house standard, especially for challenging analyte systems.
Our investment in automation and monitoring technology gives production staff the data they need to keep parameters right on target. Chlorination and condensation carry risks—personnel wear full PPE and our exhaust systems capture fugitive emissions right at the source. Our in-plant wastewater control has direct knock-on effects for finished product quality: less background contamination, smaller lot-to-lot variability. Over time, our water use footprint declined by almost 30%, a direct result of our circular cleaning system tied to our purification columns.
Many large-scale indicator dye producers quietly offload waste to third-party handlers. In contrast, we built in solvent recovery and acid neutralization capacity to ensure ongoing compliance. While market prices fluctuate, we have stayed committed to the production of batches where both purity and environmental responsibility are visible in the documentation—and in site tours we provide for partners and customers. We keep internal batch logs that allow for full traceability, and our auditing team regularly brings up small process improvements that shave off grams of reagent waste and tighten up yield performance. These steps matter, not just for audits, but for everyday peace of mind on the production floor.
We learned hard lessons about moisture uptake and air sensitivity. Dosing errors and packaging-related clumping drove multiple improvements to humidity control in our packing lines. Each poly-liner or amber glass container gets filled by staff familiar with those little warning signs: a slightly sticky flow, or a faintly musty odor from ambient exposure. Product leaving our floor receives tamper-evident seals after inline NIR checks. This step didn’t always seem essential, but repeated customer returns from oxidized batches convinced us otherwise. Over time, our lot-release criteria evolved: routine checks for residual solvents, plus old-fashioned tactile checks by the shift supervisor.
For select clients, we developed specialized dosimeter vials and water-stable sachets. The work behind these extends beyond simple packaging—each must withstand transport delays and rough handling. Our outgoing shipments travel with stability data drawn from real-world scenarios, not just regulatory minimums. Chemists, even with the best intentions, sometimes store indicators under less-than-ideal conditions, so we over-engineered our labels and desiccant packs to prevent color shifts or shelf-life losses.
University chemistry departments often request small, high-performance batches for research on trace analyte detection. These teams depend on sensitive fluorescence gradients, and variable quality in starting indicators derails entire experimental runs. We take pride in curating these lots: drying stages extend a bit longer and each package ships with a full set of spectral scans. These customers regularly report fewer spectral interferences and greater reproducibility in coursework and advanced method development.
Our ongoing fieldwork with industrial labs developing new environmental monitoring kits has highlighted another critical aspect: compatibility with automated dosing and microfluidic systems. Dyes showing even a hint of precipitation or slow disintegration can jam automated needles or microchannels. We measure and sort each batch by dissolution time and minimum particle size. In a few cases, this led us to reprocess whole lots before shipment, prioritizing ease of use for automated setups. Those insights rarely appear in specification sheets, but drive our behind-the-scenes adjustments in both milling and filtration.
Technical teams working with photostable markers in industrial-scale dye tracing or hydraulic studies often demand bulk shipments. For fieldwork in river tracing or underground flow mapping, performance hinges on both solubility and lightfastness. We’ve fine-tuned our drying processes, extending vacuum steps to preserve shelf-stability in harsh conditions. Shipments destined for field scientists arrive in moisture-guarded drums with each pallet tested for brightness index and absence of particulate contamination.
Our product sees use in medical diagnostics as well, where clean baseline fluorescence ensures accurate, reproducible measurements. Here, consistency between lots trumps raw output volume. Each medical client, whether in Asia, Europe, or North America, seeks a partner rather than a faceless supplier—they want real-time notification of lot changes, access to supporting analytical documentation, and guaranteed shipment schedules. Meeting these needs draws on our internal expertise and willingness to maintain smaller, high-purity runs alongside our larger industrial processes.
Feedback from regulatory agencies and large-scale purchasers influenced our decision to develop fully traceable batch records. Digitizing this information helps track trends across years, pinpointing recurring minor defects and correlating them to process or raw material changes. By rolling out advanced monitoring and digital twin modeling on our newer production lines, our engineers catch fluctuations in real-time. So, if downstream labs flag an unexpected color drift or solubility change, our investigation quickly homes in on the batch in question, avoiding broader market disruption.
Emerging trends show growing use of 2',7'-Dichlorofluorescein in cell biology and environmental monitoring platforms that rely on miniaturized, high-throughput analysis. These applications demand materials with improved stability under intense lighting and in varied solvent systems. Process development chemists at our plant push research into cleaner starting reagents and gentler purification routes—sometimes opting for energy-intensive, multi-stage filtration rather than quick-and-dirty crystallization. We invest in employee training that builds expertise in high-purity dye synthesis and in troubleshooting edge-case sample preparation challenges. These strategies keep our materials aligned with tomorrow’s research and industry standards, not just today’s needs.
Every gram of 2',7'-Dichlorofluorescein that leaves our facility carries a story tied to our team's persistent improvement and hands-on chemistry. Success comes from hard-earned lessons: missed endpoints in titrations, discolored solutions, delays in shipment, investments in workplace safety, and relentless feedback from those who use our dye in applications ranging from teaching to top-tier research. Our approach ties quality to practical use, not just numbers on a certificate.
This chemical has carved out its place in analytical chemistry and life sciences, standing apart from simple commodity dyes and standard indicators. The investment we make in refining every step—raw material sourcing, process design, waste recovery, and even packaging—reflects not only compliance but commitment. Our stories and records show achievement, shortfalls, and ongoing adaptation, all focused on delivering a product that serves scientists and industry with real reliability. The value of our 2',7'-Dichlorofluorescein grows out of the close, sometimes imperfect dialogue between manufacturer and end-user, kept honest by the shared goal of trustworthy science.