Chengjiang, Yuxi, Yunnan, China sales1@sinochem-nanjing.com
Follow us:

2,4,6-Tribromoanisole

    • Product Name 2,4,6-Tribromoanisole
    • Alias TBA
    • Einecs 221-967-7
    • Mininmum Order 1 g
    • Factory Site Chengjiang, Yuxi, Yunnan, China
    • Price Inquiry sales1@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    119473

    Chemical Name 2,4,6-Tribromoanisole
    Molecular Formula C7H5Br3O
    Molecular Weight 360.83 g/mol
    Cas Number 24155-93-7
    Appearance White to pale yellow solid
    Melting Point 52-54°C
    Boiling Point 150°C at 6 mmHg
    Solubility In Water Insoluble
    Odor Musty, moldy odor
    Density 2.29 g/cm³
    Pubchem Cid 66345
    Synonyms 2,4,6-Tribromo-1-methoxybenzene

    As an accredited 2,4,6-Tribromoanisole factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The 10g 2,4,6-Tribromoanisole is packaged in an amber glass bottle with a secure screw cap, labeled with hazard and identification information.
    Shipping 2,4,6-Tribromoanisole is shipped in tightly sealed containers, protected from light, moisture, and incompatible substances. Packaged according to hazardous materials regulations, it is labeled with appropriate safety and hazard symbols. Transport is conducted under controlled temperatures, typically via ground or air freight as specified by safety guidelines for chemical shipments.
    Storage 2,4,6-Tribromoanisole should be stored in a cool, dry, well-ventilated area, away from sources of ignition and incompatible materials such as strong oxidizers. Keep the container tightly closed and protected from moisture and light. Store in a chemical safety cabinet if possible, and ensure proper labeling. Follow all relevant safety and environmental regulations for storage and handling.
    Application of 2,4,6-Tribromoanisole

    Applications of 2,4,6-Tribromoanisole in Industrial Manufacturing



    2,4,6-Tribromoanisole is a specialty aromatic compound, valued in select industrial supply chains for its sensory impact and transformation in high-purity organic syntheses. Our production adheres to stringent quality protocols, serving well-established markets where this material plays a measurable but tightly controlled role. Below, we detail primary sectors with authentic downstream applications based on actual industry practices.



    1. Flavor Masking and Odor Control in Food Packaging



    Food and beverage packaging manufacturers integrate 2,4,6-tribromoanisole in extremely limited, controlled applications to study and manage aromatic off-notes arising from packaging materials. Specialized research and technical remediation workflows utilize this compound for in-process benchmarking, supporting the compliance of paperboard or cork-based closures with global food contact safety regulations. It functions as both a marker compound for aroma assessment panels and a calibration agent within QA protocols targeting the exclusion of cork taint and related taints in bottled goods.


    Industry compliance standards



    • EU Regulation No 10/2011 (plastic food contact materials)

    • FDA 21 CFR 176.170 (components of paper and paperboard in contact with food)

    • JECFA/FAO contaminant limits for aromatic compounds

    • ISO 13302 Sensory Analysis — General Guidance


    Typical usage ratio



    • 0.1–2.0 ppb in packaging simulation or calibrations; levels strictly regulated to minimize any migration and avoid consumer exposure. Final trace choices depend on substrate type and risk assessment data.


    Downstream process integration



    • Added to matrix simulations in laboratory QC, then tracked during sensory evaluation and migration studies. Not directly present in consumer-facing end-use at actionable levels.


    Final product types



    • Beverage corks (QA calibration),

    • Paper-based food cartons (analytical controls),

    • Plastic closure systems in wine and specialty drinks (contaminant profiling),

    • Research samples for packaging certification workflows.



    2. Analytical Standards Supply for Aroma Quality Control



    Producers of analytical standards utilize 2,4,6-tribromoanisole to formulate certified reference materials (CRM) supporting the food, beverage, and environmental testing industries. Reliable calibration of gas chromatography and mass spectrometry instruments requires ultra-high purity reference batches, assisting downstream QA labs in trace-level detection of off-odors and taint compounds during quality checks on foods, beverages, and packaging materials. Our GMP-managed production facilitates consistent supply for these scientific formulations under strict contamination controls.


    Industry compliance standards



    • ISO 17034 (Competence of Reference Material Producers)

    • ISO/IEC 17025 (Testing and calibration laboratories)

    • AOAC Official Methods (chromatographic analysis in food and environmental matrices)

    • USP–NF/EP (analytical grade purity requirements, where applicable)


    Typical usage ratio



    • 10–500 ng/mL in methanolic or aqueous CRMs supplied to laboratories. Levels match method calibration requirements based on instrument sensitivity and test matrix.


    Downstream process integration



    • Incorporated into CRM formulation workflows as the active reference component; shipped to accredited labs as ready-to-use analytical blends for instrument calibration and proficiency testing.


    Final product types



    • Certified gas chromatography standards,

    • Proficiency testing kits for sensory off-taints,

    • Internal QA controls for beverage bottlers and packaging converters,

    • Traceable solutions for analytical instrument manufacturers.



    3. Environmental Contaminant Source Tracking in Compliance Auditing



    2,4,6-Tribromoanisole is deployed within third-party laboratory services and environmental engineering audit toolkits to benchmark odorant pollution in industrial and municipal waste streams. Its detection at trace levels serves as a marker for biogenic or microbiologically-induced spoilage during wood storage, water purification, or recycling operations. Our precisely characterized material supports authorities and downstream users in pinpointing contaminant sources as part of regulatory risk assessments and waste remediation projects.


    Industry compliance standards



    • US EPA Method 6040 (Analysis of Taste and Odor Compounds in Water),

    • EN 15768 Water Quality (Multimethod GC/MS protocol),

    • ISO 17025 quality management for environmental testing,

    • OECD guidelines for chemical testing (for validation studies).


    Typical usage ratio



    • Calibration/control spikes ranging from 1–50 ng/L in water matrix studies; quantity adjusted based on anticipated contaminant background and sample sensitivity.


    Downstream process integration



    • Added into environmental sampling kits or research tests as part of site audits for odorant pathway mapping, then measured during certified lab analysis of air, water, or solid matrices.


    Final product types



    • Field sampling kits for odorant monitoring,

    • Environmental risk analysis reports with certified contaminant tracking,

    • Compliance audit documentation for regulatory authorities,

    • Remediation protocol validation records.



    4. Intermediate for Synthesis of High-Value Aromatic Compounds



    Advanced chemical manufacturers and contract synthesis providers leverage 2,4,6-tribromoanisole as a synthetic intermediate in select organic transformations. Its tribrominated aromatic structure enables targeted functionalization—particularly in pharmaceutical, agricultural, and fine chemical research & development. We supply material verified for low residual color and reproducible reactivity, assuring compatibility with downstream coupling, halogen exchange, and cross-coupling technologies for high-purity end-uses.


    Industry compliance standards



    • ICH Q7 Good Manufacturing Practice for Active Pharmaceutical Ingredients (for custom pharma intermediates),

    • REACH Registration,

    • ISO 9001:2015 Quality Management (for tracked chemical synthesis),

    • Internal batch traceability protocols for fine chemical integration.


    Typical usage ratio



    • Stoichiometric addition: 0.8–1.2 mole equivalents relative to the target synthetic step, with precise equivalents chosen based on the downstream process (e.g., Suzuki or Ullmann coupling yields).


    Downstream process integration



    • Introduced in batch or continuous flow synthesis as a halogenated aromatic substrate for coupling, derivatization, or selective demethylation in early- or late-stage routes, immediately preceding target product isolation steps.


    Final product types



    • Specialty crop protection chemical intermediates,

    • Fine organic electronic materials,

    • Pharma R&D candidates (where applicable under synthesis development),

    • Advanced ligands for catalytic screening.

    Free Quote

    Competitive 2,4,6-Tribromoanisole prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    2,4,6-Tribromoanisole: A Chemist’s Perspective on Quality, Performance, and Real-World Demands

    Understanding the Substance: More than a CAS Number

    Long before a drum of 2,4,6-tribromoanisole leaves our reactors, we spend countless hours studying its behavior. In our business, 2,4,6-tribromoanisole, commonly referenced by its CAS number 2417-86-7, doesn’t just represent a line on a catalog. It carries a distinct reputation, known throughout the industry for its sharp, earthy-musty aroma, even at parts-per-trillion concentrations. Testing in-house confirms why the wine and food packaging sectors approach this molecule with a wary respect: anyone who’s ever traced a cork taint problem back to its source has found 2,4,6-tribromoanisole lurking at the end of a long trail of analysis. On our factory floor, this compound represents both challenge and responsibility.

    Each batch goes through purification routines honed by decades of experience. It’s easy to underestimate just how stubbornly some byproducts cling, especially when working at the fine edge of bromination chemistry. There’s never a shortcut that works. Crystallization protocols and solvent handling ideas get revised often, not once a year, but as soon as analytics or customer feedback point to subtle shifts in the profile.

    Production Details: Decisions That Matter

    In today’s catalogue, our main offering consists of 2,4,6-tribromoanisole with a minimum purity of 99%. We monitor the compound using both HPLC and GC-MS, because any shadow of contamination can send a finished product off track for a customer. The odorous thresholds are so low that a few micrograms per kilogram make the difference between a usable end-product and a rejected lot—whether those products are wine, juice, or complex finished plastics.

    Some clients send us post-production swabs, hunting for sources of off-odors in warehouses or bottling lines. Working alongside their analytical teams, we run parallel batches under slightly varied conditions, adjusting solvents or reaction temperatures. One year, a spike in tribromoanisole complaints traced back to specific batches of wooden pallets, setting off an industry-wide hunt for sources of microbial bromination on packaging materials. Our chemists stay engaged in these real-world feedback loops, and each new story further refines our process controls.

    Recognizing the Risks and Demands of Trace Detection

    People who only know tribromoanisole from textbooks might not appreciate the sensitivities involved. While many chemicals get handled in kilogram, even ton quantities, this compound’s presence often gets flagged at the nanogram level. A drop in purity, a slip in equipment decontamination, or a hurried wash step, and the end product risks tainting a shipment of premium wine or a beverage bottling line.

    Customers and regulatory bodies maintain strict requirements; we receive requests for detailed impurity breakdowns, historical batch analytics, and third-party verifications. This pressure pushed us to install direct-inlet mass spectrometry years ago, long before it became standard. Early adoption cost us in downtime and retraining, but there’s peace of mind knowing our product won’t spark a recall halfway across the globe.

    Through decades on the manufacturing side, we see firsthand how easy it is for a material like tribromoanisole to undermine finished goods, not through toxicity but by sheer sensory potency. Every shift in humidity, drum material, or even wall paint inside a warehouse can change how much of this chemical becomes airborne or migrates through packaging layers.

    A Product that Shapes Protocols, Not Just Outcomes

    People trace 2,4,6-tribromoanisole’s challenges beyond the lab. Major wine and spirit brands invest heavily in lateral-flow detection kits and GC-based analyses, aiming to intercept taint at every stage. Buffer storage environments get planned down to the last detail, and wood selection for barrels or crates includes screening for both precursors and the end compound.

    We’ve partnered directly with cork harvesters and bottling facilities during major taint investigation campaigns. The product itself rarely gets used deliberately; it arrives through contamination or unintended reaction between natural precursors and free bromine sources. This puts us, as its main manufacturer, in a unique position: asked to supply reference standards, but also to advise on methods that keep it out of finished goods altogether.

    Applications: Reference, Tracing, and Investigative Work

    Most requests for 2,4,6-tribromoanisole come from research labs, quality control units, or environmental consultants. Demand for primary material has grown, but not for industrial use on a massive scale—its role is almost exclusively analytical and forensic. Cork producers request standard samples to validate rinse and decontamination protocols. Beverage companies use our high-purity materials to calibrate sniffing and detection panels. Sometimes, adhesives and packaging testing facilities ask for larger quantities to recreate real-world contamination scenarios in-house, stress-testing the limits of sensory panels.

    A recurring pattern emerges: genuine, high-purity 2,4,6-tribromoanisole isn’t easy to source reliably. Imports sometimes claim 98% or higher, but show UV-active and polar impurities on close inspection. Tiny differences in impurity profiles explain variations in aroma, shelf stability, and even chromatographic response—small errors in the standards cascade into big errors in routine QA sampling. Our in-house labs spend time every month fielding requests to “batch match” specific lots, supporting not just external clients but our own traceability records.

    The Value of Consistent Standards

    All sorts of substitution questions come in, especially from materials scientists looking for standards that behave similarly in gas phase or have comparable retention times. The reality is, there aren’t many naturally occurring compounds with the precise volatility, hydrophobicity, and chemical resilience of 2,4,6-tribromoanisole. Structural analogs and other trisubstituted anisoles show different affinity for certain packaging films or vary in volatility. Even 2,4,6-trichloroanisole, the better-known cousin found in some wine taint scandals, travels differently in polymer and cellulosic systems, making headspace analysis less straightforward.

    Any deviation from precise tribromoanisole specifications means altered recovery rates, false positives, or sensor drift in real laboratory setups. For QA teams, the only thing worse than a confirmed contaminant is a false alarm—both scenarios wreak havoc on production schedules and lead to unnecessary wastage.

    Comparison With Other Products: Details Matter

    We field a lot of questions about what sets our tribromoanisole apart from broader offerings. Besides purity and traceability, the difference often comes down to control over both impurity spectrum and scent intensity, which defines real-world performance in trace analysis. Larger traders and resellers rarely specify storage protocols and cross-contamination safeguards. In our plant, collection drums, gaskets, and venting units get purged and tested to avoid repeating the very contamination issues our clients spend millions to prevent downstream.

    Other manufacturers list “specification compliant” purity, but often skip background checks for polybrominated biphenyls and similar byproducts. We find these can easily slip through lower-grade columns or evade common test panels. Over the past decade, as detection limits dropped and off-flavor trials intensified in the beverage and packaging sectors, our clients increasingly appreciate certification that covers not just major peaks, but a slew of minor impurities.

    Clients sometimes try to rely on chemically similar compounds for calibration or simulate taint events using less hazardous or less odorous analogs. These substitutes fail to provide the necessary sensory signature or chromatographic confidence. Chemists in food and beverage sectors often find themselves going back to 2,4,6-tribromoanisole for both research and training, as even small differences in side-product profiles radically alter detection routines.

    Storage Needs and Handling: More Than Just Paperwork

    Years in the business have shown that packaging material affects the stability of tribromoanisole more than many realize. Our drums use fluoropolymer liners that resist permeation, reducing the risk of cross-contamination with volatile compounds or surfactants carried by plasticizers. In some plants, bulk inventory gets stored in epoxy-lined vessels under constant air filtration, resulting from hard lessons after off-flavor events traced back to unnoticed leaks or capped lines.

    We learned early that routine lab procedures need adaptation too. Analytical samples get dispensed using pre-cleaned glassware, and all workspace airflow patterns are designed to avoid cross-exposure. Training new team members involves both the science and the ethics of material preservation, focusing on minimizing every point where air or dust could introduce foreign volatiles. Even so, we still see periodic breakthroughs—new pump technology, even new sealing concepts—that tighten confidence that future clients won’t face costly recalls or waste.

    Regulatory Attention and Industry Response

    Over the past decade, as global taste and fragrance houses raised their scrutiny, international standards on trace contaminants have intensified. Countries once satisfied with organoleptic sniff tests or basic GC-FID screening now demand full impurity disclosure sheets and long-term shelf-stability data. Our teams spent thousands of hours developing documentation to show not just compliance with statutory limits but an understanding of how tribromoanisole migrates, persists, and transforms throughout supply chains.

    Feedback loops from customer audits often change upstream production. If a major food client finds an unexpected tailing impurity, our analysts start process mapping that same day. Documentation now describes both major peaks and a range of coeluters, as well as performance during storage, freeze-thaw, and open-air handling. Regulatory bodies appreciate this focus on actual performance, not simple box-checking. Our reputation continues to benefit from refusing to compromise on batch-to-batch integrity, even if it means higher reject rates at our own QC lines.

    Supporting Discovery and Prevention

    Despite the reputation 2,4,6-tribromoanisole holds for causing headaches to brand owners, its very existence keeps quality systems sharp. As one of the main laboratories supplying high-purity tribromoanisole, we receive regular calls to advise on root-cause investigations and remediation trials. Cork, wood pallet, and synthetic packaging manufacturers consult us about strategies for minimizing formation through better rinsing, selection of lower-bromine fungicides, or redesign of warehouse airflow.

    One practical solution that emerged stems from direct conversation between manufacturers and clients: shared early detection procedures using pooled reference samples. Instead of each player relying independently on sporadic, sometimes questionable supplies, entire industry groups now participate in round-robin proficiency testing, using our tribromoanisole as the common baseline. The result: fewer surprises during audits and a more trustworthy certification trail.

    Software and analytics companies began integrating our reference data into sensor calibration packages, allowing faster, more reliable identification during plant monitoring. These partnerships tip off production managers to incidents long before consumer complaints reach the market. Success stories from customers highlight the real-world value in predictable, high-purity supply chains—every incremental improvement upstream equates to fewer headaches for both manufacturers and end users.

    Challenges for the Future: Staying Ahead of Sensory Science

    With detection limits moving ever lower, and consumer panels growing more sophisticated, the margin for error continues to shrink. New research sheds light on possible additive or masking effects with unrelated contaminants—making single-compound purity only part of the story. That’s why our labs keep refining not just the final purification, but the pre-cleaning and impurity monitoring steps embedded at every stage of production.

    One area of current development focuses on improvement of closed-handling systems that prevent airborne migration during weighing and dispensing. Research teams challenge us to supply larger, more tightly certified reference panels, so training programs in sensory laboratories evolve more rapidly. Clients also request expanded impurity fingerprints, providing regulators and production teams greater clarity on probable co-contaminants. Every year brings a new wave of small but significant tweaks—whether in batch sampling, packaging design, or analytical support—that together secure client brands and minimize consumer risk.

    Engagement with the Industry: No Such Thing as ‘Standard’ Tribromoanisole

    As a manufacturer rooted in direct production and hands-on chemical engineering, our experience with 2,4,6-tribromoanisole extends from reactor vessel to finished analytical standard. At every stage, awareness of its real-world impact—not just its chemical formula—shapes how we approach our work. Continual advances in analytical chemistry, and industry-driven feedback, motivate us to keep our processes transparent, responsive, and resilient to emerging challenges.

    Compared to basic reseller material, our product stands out not by any single innovation, but through careful, consistent improvements accumulated every year. This includes maintaining legacy documentation on every batch, revisiting cleaning protocols quarterly, and investing in cooperative testing methods that integrate client feedback. Our aim is not just to meet minimum standards, but to anticipate future detection needs, contamination pathways, and application requirements—so our partners in research, quality control, and manufacturing can focus on innovation without worrying about their foundational reference materials.

    In our view, every lot of 2,4,6-tribromoanisole represents both the culmination of past lessons and an invitation to keep learning. The journey from raw bromine sources to a clean, stable, and reproducible final material involves hundreds of daily choices, each with real consequences for client outcomes. We keep the doors open to industry feedback and scientific debate, drawing on both legacy insights and new research to strengthen trust in every gram that leaves our facility.