HS Code |
130933 |
| Name | 1,2-Benzanthracene |
| Cas Number | 56-55-3 |
| Molecular Formula | C18H12 |
| Molecular Weight | 228.29 g/mol |
| Appearance | Pale yellow crystalline solid |
| Melting Point | 163-165 °C |
| Boiling Point | 437 °C |
| Density | 1.24 g/cm³ |
| Solubility In Water | Insoluble |
| Synonyms | Benz[a]anthracene |
| Chemical Class | Polycyclic aromatic hydrocarbon |
| Odor | Aromatic |
| Flash Point | 228 °C |
| Ec Number | 200-276-5 |
| Pubchem Cid | 9154 |
As an accredited 1,2-Benzanthracene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for 1,2-Benzanthracene (25g) is a sealed amber glass bottle, labeled with hazard symbols and chemical information. |
| Shipping | 1,2-Benzanthracene should be shipped as a hazardous chemical, following all applicable regulations (such as DOT, IATA, and IMDG). It must be packed in tightly sealed containers, clearly labeled, and protected against physical damage. Use appropriate secondary containment and documentation, and ensure handling by trained personnel equipped with suitable personal protective equipment (PPE). |
| Storage | 1,2-Benzanthracene should be stored in a tightly closed container, in a cool, dry, well-ventilated area away from incompatible substances such as strong oxidizers. It should be kept out of direct sunlight and protected from moisture. Storage areas must be clearly labeled and secure, minimizing all potential sources of ignition due to its flammable and hazardous nature. |
Applications of 1,2-Benzanthracene in Industrial ManufacturingAs a direct manufacturer specializing in high-purity 1,2-Benzanthracene, we support a select range of advanced industry segments where this compound forms a necessary component in critical chemical transformations. Our application guidance is based on verified client usage, regulatory frameworks, and proven industrial integration. 1. Intermediates for Polycyclic Aromatic Hydrocarbon (PAH) Research ReagentsResearch laboratories and chemical synthesis companies use this molecule as a primary substrate in the controlled synthesis and analytical tracing of complex PAHs. In this context, laboratories focus on mechanism studies, reference reagent formulation, and the generation of isotope-labeled standards for environmental and toxicological investigations. Rigorous purification and documentation requirements ensure precise traceability and batch integrity for further reaction chains. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
2. Synthesis of Fluorescent Tracer Dyes and ProbesChemical and biotechnology manufacturers utilize this aromatic core as a precursor in specialized processes for producing high-performance fluorescent dyes and molecular tracers. Its unique conjugated structure enables further functional group modifications that are essential for advanced dye chemistry, including probes for microfluidic analysis, biological labeling, and membrane tracing in cell imaging applications. Downstream refinements require close documentation of material origin and consistent impurity control to meet assay interference limits. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
3. Starting Material in High-Performance Polyimide Resin ProductionDemand from advanced polymer and electronic material manufacturers drives the use of this compound as a building block in the synthesis of specialty polyimide resins. These resins feature enhanced thermal stability and electrical properties, supporting the fabrication of flexible electronics, insulation films, and composite materials for aerospace and microelectronics. Product integration requires precise control over aromatic monomer content to achieve the targeted film performance and processability. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
4. Reference Standard for Environmental and Industrial Hygiene TestingEnvironmental monitoring labs and industrial hygiene analysis services rely on our product as a certified reference material for quantifying PAH contamination in air, soil, and water matrices. High analytical purity supports reproducibility across regulatory methods, while full traceability documentation meets validation requirements in both routine and incident-driven assessments. Laboratories calibrate and validate their detection protocols using reproducible standard concentrations supplied by the original manufacturer. Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
|
Competitive 1,2-Benzanthracene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8618112911328 or mail to sales1@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Working with chemicals like 1,2-Benzanthracene every day, we see firsthand how dependable sourcing and strict process control make a difference for research labs and industrial customers. The way we handle this polycyclic aromatic hydrocarbon (PAH) isn’t guesswork. Years at the reactor face and in the QC lab have shaped how we refine purity and manage batch consistency. Any lab chemist or process engineer will spot the difference between product that’s been handled “by the book,” and output where the team knows the realities in the plant.
1,2-Benzanthracene, with the structure often referred to as naphthacene fused with a benzene ring, enters the market as a pale yellow crystalline powder. Its formula, C18H12, might look simple to someone new to PAHs, but its formation and subsequent handling aren’t boring for those of us who craft it. Laboratory users probably know this chemical as a reference material for analytical methods, environmental PAH studies, or as a building block for synthetic organic work. In process applications, it sometimes helps investigate thermal stability and photodegradation phenomena in aromatic compounds.
Every batch starts with raw materials we vetted through long supplier relationships. The synthesis, which leverages high-temperature cyclization of naphthalene derivatives, requires both steady hands and consistent environmental controls. Reaction conditions can swing the impurity profile. Lower quality manufacturers sometimes miss traces of isomeric benzanthracenes like 1,12- or 3,4- types. Years in this line teach that subtle impurities influence research results, especially in chromatographic and toxicology studies dependent on sharp baselines.
Our QC team runs HPLC, GC-MS, and melting point analyses on each lot, because missing a minor impurity isn’t an academic mistake—it’s a trust issue for the next lab in the supply chain. Typical purity surpasses 97%, with some requests strict about reaching 99+% for calibration work. Handling characteristics, like clumping due to static or air exposure, show up during bottling. We solve these issues by tight environmental controls and rapid packaging, minimizing airborne contamination and product degradation.
Commercial 1,2-Benzanthracene generally comes in packs of 1g, 5g, or up to 100g, using amber glass ampoules to shield from light and moisture. Each pack includes a lot-specific COA, signed by the on-duty batch chemist, not an anonymous office. We keep particle sizing between 40 – 150 mesh, because labs crushing lumps for a standard curve seldom thank you for unnecessary work.
Solubility always gets questions. We see 1,2-Benzanthracene dissolve in hot benzene, toluene, chloroform, and at higher rates in dichloromethane. In cold solvents, users struggle. We encourage prep with pre-warmed solvent and minimal exposure to air, advice that’s saved more than one research schedule. Melting point hovers in the 163–165°C window, but careless suppliers sometimes push lower-melting contaminants through. Stability decreases under UV, so we package and store fully shielded.
Some folks wonder about long-term stability. We’ve yet to see significant degradation under dry, dark storage for over 18 months, but even tightly capped bottles slowly pick up environmental contaminants. We date-test retention samples for each batch, so we can trust what sits on our shelves as much as what ships out.
Researchers in environmental analysis lean on 1,2-Benzanthracene as a PAH marker for air particulate, soil, and water pollution studies. It sits on EPA and EU analytical target lists, so regulatory labs want certified reference material, not “close enough” product. Synthetic organic chemists explore it during fused ring syntheses or when testing photocatalytic and oxidative pathways relevant to specialty chemicals and pharma intermediates.
Toxicologists test 1,2-Benzanthracene for activity in mutagenicity and carcinogenicity screening given its aromatic structure, though its behavior diverges from higher-profile PAHs—an observation that still drives mechanistic research today. Manufacturers like us separate 1,2-Benzanthracene cleanly from isomeric and higher molecular weight PAHs to prevent cross-interference in these studies. Our technical support team often steps in to help labs optimize dissolution and analytic protocols because small technique changes sometimes make the difference between a success and a costly repeat.
1,2-Benzanthracene differs from common PAHs like naphthalene or anthracene not just in size, but reactivity and photostability. Those working with the benzo[a]anthracene or benzo[b]fluoranthene series notice a shift in aromatic character and challenge in separation, especially on silica chromatography. Our control over the synthesis route gives a clean profile specific to the 1,2-isomer, important for those measuring just this analyte in mixed samples.
Physical appearance signals batch quality. Well-made 1,2-Benzanthracene carries a consistent color and morphology, without visible gray or orange tints that betray handling errors or overexposure to air. We rarely see significant batch-to-batch deviation in melting point or solubility—an advantage for researchers unwilling to recalibrate methods every order. Use in standards prep demands repeatability, so our QC procedures cut out the surprise elements that come from relying on intermediaries or third-party reselling.
Our technical support lines often ring with questions about storage, stability, and analytical interference. The experience manufacturing 1,2-Benzanthracene shapes our answers—it’s not uncommon for customers to struggle dissolving the product in cold solvents, for example. We recommend heating solvents gently and minimizing atmospheric exposure during weighing and transfer.
Some customers need the highest certification for regulatory compliance. Our labs use calibration reference standards certified by national metrology institutes as comparators, tightening our internal reference frames and ensuring downstream credibility. It’s our responsibility to back every COA with on-site records, batch sample retention, and full traceability.
Working with 1,2-Benzanthracene demands care. Dust generation is minimized at our packaging stations, with enclosed transfer and local exhaust. Workers wear tight-fitting respirators and gloves, not by regulatory edict, but because long shifts with PAHs demand extra vigilance. Our shopfloor protocols aren’t just written for inspectors—they’re how we keep ourselves and our coworkers safe year after year. This firsthand experience translates into practical, actionable advice for our customers, like the merits of using chemical fume hoods and glovebox techniques even outside formal regulatory requirements.
We educate buyers about its classified hazards: potential mutagenicity, environmental persistence, and the need for professional disposal. The storage advice we share comes out of our daily handling—atmosphere, temperature, and light all matter. We advise storing in a dry, cool, and dark environment, tightly capped, with minimal exposure to minimize degradation and cross-contamination.
Producing 1,2-Benzanthracene without batch-to-batch variation takes experience. Many labs see commercial PAHs that differ in color, purity, or handling each year. Our process narrows synthesis conditions, allows for small-scale test runs before main batches, and maintains robust in-process monitoring. Batch chemists monitor reaction intermediates with spectroscopy and thin-layer chromatography, rather than relying just on final purification. This upstream vigilance knocks out most process-related impurities before they ever muddy a final product.
Packaging and transportation of such sensitive crystalline solids also bring lessons. Moisture ingress, light, and mechanical agitation knock down product quality if left unchecked. That’s why our operations limit exposure to daylight and use padded, sealable glass containers. We hand-inspect bottles for particulate or clumping—and anyone who’s opened a clumped batch will appreciate this extra step. Global transport sometimes adds transit heat spikes; we include temperature dataloggers for large shipments so labs know their material stayed stable all the way.
As manufacturers, we view customer queries less as interruptions and more as evidence that people value knowing what’s behind the label. End-users trust us with details about their application, which means we listen, trace problems, and modify protocols as needed. Our service team maintains lab notebooks, historic analytical spectra, and process logs from each batch, so any customer issue can be traced and fixed rapidly based on firsthand data, not guesswork.
Many technical calls emerge from analytical interferences. Researchers analyzing complex PAH mixtures sometimes find unknown baseline noise or diminished peak resolution. We dig into chromatograms, help optimize extraction or dilution techniques, and share best practices taken from in-house method validation. Few things in our workflow are as satisfying as helping a frustrated lab tech find the missing piece and push a project forward.
Purchasing straight from us gives assurance that the product’s journey didn’t involve unnecessary handling and storage variables. We document chain of custody from raw materials to finished goods, a step increasingly significant for regulatory and accreditation audits. Comparison tests show nuanced differences between direct-from-factory product and batch-blended material from distributors. Subtle shifts in impurity profiles, exposure-related yellowing, or even problematic particle sizing disrupt methods and compound costs for users down the line.
We keep our warehousing disciplined. Raw materials sit separate from synthesized PAHs, and environmental controls extend to everyday storage, not just regulated lots. Barcode-tracking matches customers to specific production lots, allowing rapid traceback if an issue ever bubbles up. We share this transparency because our experience tells us that open records and consistent procedures prevent small mistakes from compounding into larger ones.
Manufacturers handle the full product lifecycle. We set product specifications, control for impurities, and own the documentation behind supply, which you won’t find with middlemen repackaging drums in anonymous warehouses. Our bottles leave the plant filled under dust-controlled air, by people trained in this specific compound. Product shelf-life, analytical support, and replacement policies are all shaped by our own experience, not generic guidance copied from supplier sheets. Customers can reach the chemist behind the batch when something goes off-script.
Distributors routinely face issues with repackaging, blending, or mixing lots from different sources. Our chemists see this in the field during joint troubleshooting calls: unexpected baseline artifacts, inconsistent melting points, or off-odors. Ensuring supply chain reliability shouldn’t fall to the user—producers like us take that on because we know mistakes downstream can cost weeks of lost experiments or flawed compliance data.
We keep improving our process by staying in close dialogue with customers. As analytical detection gets sharper and regulatory limits drop, trace impurities in PAHs matter more. Our in-house R&D team evaluates better purification steps and improved storage techniques based on what we learn with each produced batch. We share updates and data from these improvements so users can trust each bottle matches and exceeds their expectations.
Tighter analytical tolerances and growing demand for environmental toxicology make product reliability central. Research agencies trust us with their standards for a reason: we document, test, and vouch for each step. We treat feedback not as criticism, but as partnership—each return or query helps fine-tune operations, reduce error, and push for safer, more consistent supply. It’s easy to talk about quality; it’s more meaningful to show it, day after day, one bottle at a time.
Handling 1,2-Benzanthracene teaches a respect for detail across the manufacturing process, from raw material vetting through synthesis, purification, QC, and packaging. Every chemist, technician, and packager on our team understands how choices made in the plant echo through customer labs—whether in a single research run or in multi-year environmental programs. Reliable supply, transparent records, technical support, and product backed by hands-on knowledge form the foundation for trust that endures in every bottle we ship.