Yinchuan, Ningxia, China sales8@sinochem-nanjing.com
Follow us:

Overview of materials for Nylon 11, Cable Sheathing Grade

    • Product Name Overview of materials for Nylon 11, Cable Sheathing Grade
    • Alias PA 11, Cable Sheathing Grade
    • Einecs 259-218-7
    • Mininmum Order 1 g
    • Factory Site Yinchuan, Ningxia, China
    • Price Inquiry sales8@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    109835

    Density 1.04 g/cm³
    Melting Point 189°C
    Water Absorption 0.8% (24 hr, 23°C)
    Tensile Strength 46 MPa
    Elongation At Break 150%
    Flexural Modulus 1100 MPa
    Hardness Shore D 70
    Volume Resistivity 1E13 ohm·cm
    Flammability Rating UL 94 HB

    As an accredited Overview of materials for Nylon 11, Cable Sheathing Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The Nylon 11 Cable Sheathing Grade is packaged in 25 kg moisture-resistant bags with clear labeling for easy identification and safe handling.
    Shipping Shipping for **Nylon 11, Cable Sheathing Grade** requires clean, dry, sealed packaging to protect from moisture and contamination. Material is typically shipped in bags or drums. Store and transport in cool, dry environments, away from direct sunlight and strong oxidizers. Follow all local, national, and international regulations for transportation of industrial polymers.
    Storage Nylon 11, Cable Sheathing Grade, should be stored in a cool, dry, and well-ventilated area, protected from direct sunlight and moisture. The storage environment should remain clean and free from contaminants. Keep the material in its original, sealed packaging until ready for use to prevent water absorption or deterioration, as nylon is hygroscopic and can lose its properties if improperly stored.
    Application of Overview of materials for Nylon 11, Cable Sheathing Grade

    Applications of Overview of Materials for Nylon 11, Cable Sheathing Grade in Industrial Manufacturing

    As a dedicated producer of high-performance Nylon 11, Cable Sheathing Grade, we supply material that integrates into critical electrical and industrial cable manufacturing processes. Our raw material undergoes rigorous upstream quality control to meet strict market requirements and downstream operational compatibility within specialized cable sectors. Below, we summarize key downstream industrial applications with particular process and regulatory considerations.

    1. Low Voltage Power Cable Sheathing

    Low voltage power cables for utility, commercial, and infrastructure networks require sheath materials that offer mechanical stability and extended environmental endurance. Nylon 11 in this context enables cable factories to manufacture coverings with high abrasion and chemical resistance, ensuring compliance with long-term field exposure standards. Its inherent flexibility aids extrusion stability over extensive cable runs, which is crucial for operational continuity and product certification.

    Industry compliance standards

    • IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1kV up to 30kV
    • UL 83: Thermoplastic-Insulated Wires and Cables
    • RoHS Directive (EU) 2015/863 for hazardous substance restriction
    • REACH Regulation (EC) No 1907/2006

    Typical usage ratio

    • Applied at 90–100% as the primary outer sheath compound; occasionally blended with up to 10% plasticizer where additional flexibility is required. Ratio adjustment based on wall thickness and insulation design.

    Downstream process integration

    • Compound fed directly into single-screw or twin-screw extrusion lines after pellet drying; melt processed at 210–230°C to encapsulate the insulated conductors.

    Final product types

    • Low voltage copper or aluminum conductor cables for building wiring, control cables, and energy distribution systems
    • Flexible cables for industrial equipment

    2. Fiber Optic Cable Outer Sheath

    Fiber optic cable producers adopt specialized Nylon 11 grades to construct sheaths that resist microbending, moisture ingress, and bio-environmental exposure, particularly for direct-burial and aerial installations. Performance must remain stable across wide temperature fluctuations and under mechanical tension during deployment in telecom infrastructures.

    Industry compliance standards

    • IEC 60794-1-2: Optical fibre cables – Generic specification – Basic optical cable test procedures
    • Telcordia GR-20: Generic requirements for optical fiber and optical fiber cable
    • RoHS and REACH compliance for hazardous materials
    • EN 50289: Communication cables – test methods

    Typical usage ratio

    • Used at 100% in the sheathing layer for direct cable protection, with pigment and additives comprising up to 3% depending on color and UV stabilization needs.

    Downstream process integration

    • Pellets subjected to controlled dehumidification prior to extrusion; processed during the outer sheath application stage post-buffer tube and armoring assembly.

    Final product types

    • Outdoor single-mode and multi-mode fiber cables for telecommunications networks
    • Direct burial and aerial fiber optic cables for FTTx applications

    3. Control and Instrumentation Cable Sheathing

    Industries such as process automation and transportation demand cable sheath layers that withstand exposure to hydrocarbons, solvents, and daily mechanical abrasion. Cable manufacturers employ Nylon 11’s chemical inertness and strength to comply with control and instrumentation requirements, focusing on environments where accidental contact with oils or aggressive agents may occur.

    Industry compliance standards

    • BS EN 50288-7: Multi-element metallic cables used in analogue and digital communication and control
    • UL 1277: Electrical Power and Control Tray Cables with optional oil resistance requirements
    • IEEE 383: Standard for Qualifying Class 1E Electric Cables, Field Installed, for Nuclear Power Generating Stations (for relevant control cable applications)

    Typical usage ratio

    • Integrated at 85–100% as the external protective sheath, sometimes co-extruded with up to 15% flame retardant masterbatches if additional fire safety classes are mandated.

    Downstream process integration

    • Nylon 11 pellets are metered into extruders once inner insulation and screening/braiding are complete; processing temperatures and throughput are tailored for maintaining flexibility and surface finish required by in-field installations.

    Final product types

    • Control cables for machinery, transportation, and building automation systems
    • Instrumentation cables exposed to oil, chemicals, or harsh environments

    4. Mining and Underground Cable Sheathing

    Mining cables necessitate highly resilient sheath compositions to counteract mechanical impact, moisture, cutting, and the presence of mineral oils and flame hazards underground. Nylon 11 offers a non-halogen solution that upholds safety and maintenance criteria while showing long-term resistance against these operational threats.

    Industry compliance standards

    • AS/NZS 1802: Electric cables – Reeling and trailing – For mining and general use (other than underground coal mining)
    • BS 6708: Flexible cables for mining and general purposes
    • MSHA approval (Mine Safety & Health Administration, applicable to US operations)
    • RoHS and REACH registration for mining equipment supply chain compliance

    Typical usage ratio

    • Employed at 95–100% for robust sheath requirements; addition of flame retardants or anti-fungal agents up to 5% based on mine safety rules, tailored to application risk analysis and cable diameter.

    Downstream process integration

    • Material loaded post-insulation via crosshead extrusion, with downstream curing or cooling systems configured for thicker wall builds and enhanced mechanical stress absorption.

    Final product types

    • Heavy-duty trailing and reeling cables for underground and surface mining operations
    • Electrical supply cables for tunneling equipment

    5. Automotive Wiring Harness Cable Sheath

    With the automotive shift toward advanced driver-assistance systems and electrification, cable harness suppliers rely on Nylon 11-based sheathing for under-the-hood and door-zone wiring. This configuration provides necessary resistance against automotive fluids, vibration, and prolonged heat cycles, delivering shielded cabling that meets stringent OEM quality and vehicle fire safety protocols.

    Industry compliance standards

    • ISO 6722-1: Road vehicles – 60 V and 600 V single-core cables
    • LV112: Requirements for automotive cable applications (German automotive OEM standard)
    • SAE J1128: Low Tension Primary Cable
    • RoHS and REACH compliance for vehicle component materials

    Typical usage ratio

    • Maintained at 80–95%, optionally alloyed with up to 10% stabilizers or pigments based on color specification or enhanced UV resistance targets in vehicle environments.

    Downstream process integration

    • Pellet input into high-speed sheath extrusion following conductor assembly; secondary surface treatment or laser marking possible post-extrusion for traceability and harness identification.

    Final product types

    • Sheathed wire and cable for in-vehicle electrical distribution
    • Data and sensor wiring for automotive electronics

    6. Offshore and Marine Cable Sheathing

    Marine and offshore platform cable manufacturers value Nylon 11 for its resistance to saline environments, pressure fluctuation, and biological attack in submerged or splash zone installation. Complex regulatory requirements govern these sheathings to ensure both human safety and environmental stewardship.

    Industry compliance standards

    • IEC 60092-350: Electrical installations in ships – General construction and test methods of power, control and instrumentation cables
    • DNVGL CP-0410: Type approval for low and medium voltage maritime cables
    • BS EN 50288-7: Marine and offshore instrumentation cables
    • IMO Resolution A.653(16): Code for Application of Fire Test Procedures

    Typical usage ratio

    • Blended at 100% for tough marine outer sheaths, occasionally accepting up to 4% dedicated anti-fouling or UV additive systems, depending on cable location and life-cycle risk assessment.

    Downstream process integration

    • Material introduced in line with steel wire armor and water-blocking element assembly, using specialized marine-grade extrusion lines conditioned for sub-sea or topside cable lengths.

    Final product types

    • Power and control cables for shipboard and offshore platform infrastructure
    • Subsea cables for oil & gas, wind turbine, and oceanographic sensor deployment
    Free Quote

    Competitive Overview of materials for Nylon 11, Cable Sheathing Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618005193850 or mail to sales8@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance