CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber

    • Product Name CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber
    • Alias CENTROMID 12 GF 30
    • Einecs 500-815-0
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry admin@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    872838

    Material Name CENTROPLAST CENTROMID 12 GF 30
    Polymer Type Polyamide 12 (PA12)
    Glass Fiber Content 30%
    Density 1.33 g/cm³
    Tensile Strength 110 MPa
    Flexural Modulus 4500 MPa
    Elongation At Break 4%
    Melting Point 178°C
    Water Absorption 24h 0.3%
    Color Natural
    Heat Deflection Temperature 160°C
    Shrinkage 0.4%
    Flammability HB (UL 94)
    Hardness 80 Shore D

    As an accredited CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber is supplied in a 25 kg moisture-proof, labeled plastic sack.
    Shipping CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 with 30% glass fiber is typically shipped in sealed, moisture-proof bags or drums to prevent contamination and moisture absorption. Packages are securely palletized and clearly labeled with hazard and handling information, ensuring safe transit under standard chemical transportation regulations.
    Storage CENTROPLAST CENTROMID 12 GF 30 (Polyamide 12 with 30% glass fiber) should be stored in a cool, dry, and well-ventilated area, protected from direct sunlight and moisture. Keep the material in tightly sealed original packaging to prevent absorption of humidity, which can affect processing and properties. Avoid exposure to extreme temperatures. Ensure good housekeeping to minimize contamination and dust generation.
    Application of CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber

    Applications of CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber in Industrial Manufacturing

    CENTROPLAST CENTROMID 12 GF 30 incorporates 30% glass fiber reinforcement into Polyamide 12, providing high dimensional stability, enhanced mechanical strength, and chemical resistance. Due to these properties, it is widely integrated into demanding sectors, supporting end-product performance under rigorous industrial conditions. Below, we detail key application domains based on industry standards and real-world use cases.

    1. Automotive Under-the-Hood Structural Components

    Automotive manufacturers select this grade for functional applications subject to high thermal and mechanical loads, such as air intake manifolds, engine covers, clutch and transmission housings, oil filter modules, and coolant system components. The combination of PA12 with glass fiber content maintains strength and dimensional accuracy despite exposure to thermal cycling, oils, and circulating fluids. Engineering teams often employ it for metal replacement where weight reduction and corrosion resistance drive product selection in modern engine design.

    Industry compliance standards

    • ISO 9001:2015 (Quality Management Systems for automotive components)
    • IATF 16949 (Automotive Quality Management)
    • SAE J2027 (Plastic Material Standard for Exposed Underhood Automotive Applications)
    • OEM-specific specifications (VW 50190, Daimler DBL 5404, GM GMW15449)

    Typical usage ratio

    • Used at 100% for structural elements; blend ratios (90–100%) adjusted by filler or impact modifiers for specialized properties.

    Downstream process integration

    • Melt compounded via injection molding at 250–280°C, followed by in-line machining or direct assembly into finished modules on automated lines.

    Final product types

    • Engine intake and charge air pipes
    • Oil pan baffles
    • Transmission adapters
    • Water pump housings

    2. Pneumatic and Hydraulic Hose Connectors

    Industrial and commercial fluid transfer systems utilize PA12 with 30% GF for fittings and quick connectors due to inherent resistance to hydrolysis and dimensional changes. Connector designers rely on the material’s stable long-term performance under high pressure and repetitive coupling. Custom profiles often use the product unmixed for connection adapters, Y- and T-fittings, and rotating elements in automated plant installations, replacing metal parts in both stationary and mobile equipment.

    Industry compliance standards

    • EN ISO 4414 (Pneumatic Fluid Power—Safety and Requirements)
    • DIN EN ISO 8434-1 (Metallic tube connections for hydraulic fluid power)
    • RoHS Directive 2011/65/EU (Restriction of Hazardous Substances)
    • REACH (EC 1907/2006)

    Typical usage ratio

    • Direct use at 85–100% for injection molded connector components; some OEMs blend with PA11 or PA6 for cost or flexibility.

    Downstream process integration

    • Enter downstream injection molding for single-shot or overmolded connectors; post-processing includes ultrasonic welding and leak pressure testing.

    Final product types

    • Pneumatic push-in fittings
    • Hydraulic quick couplings
    • Automotive and industrial tube connectors
    • Rotary hose nut inserts

    3. Electrical and Electronics: Cable Glands and Enclosures

    Original equipment manufacturers (OEMs) in the electrical and electronics industry use this PA12 grade to fabricate robust cable glands, junction boxes, and control panel housings. The high glass fiber content ensures flame retardance, superior rigidity, and long-term isolation, crucial in protecting sensitive electronics in industrial or outdoor environments. Electro-technical assemblies benefit from minimal creep and moisture uptake even under constant voltage or temperature fluctuation, ensuring secure cable strain relief and enclosure integrity over years of service.

    Industry compliance standards

    • IEC 60529 (Ingress Protection Rating—IPXX)
    • UL 94 V-2 (Flammability Standard for Plastic Materials)
    • EN 62444 (Cable Glands for Electrical Installations)
    • RoHS 2011/65/EU, REACH EC 1907/2006

    Typical usage ratio

    • Direct use at 95–100%, potentially filled with flame retardants according to UL classification for specific designs.

    Downstream process integration

    • Material fed into hot runner molds; included secondary machining for threading or mounting; often follows automated gasket or membrane sealing procedures.

    Final product types

    • EMC cable entries
    • Waterproof cable glands
    • Panel housing covers
    • DIN rail mountable enclosures

    4. Industrial Machinery Components

    Engineers in machinery manufacturing specify this material for load-bearing but lightweight brackets, alignment jigs, bearing cages, and cover plates. The chemical and mechanical performance properties support demanding settings such as packaging lines, printing systems, or materials handling equipment, where steel or aluminum would suffer from wear or toxicity requirements. Parts produced must meet close-tolerance geometrics for automated assembly and often require resistance to lubricants and coolants.

    Industry compliance standards

    • EN ISO 12100 (Safety of Machinery—Risk Assessment)
    • ISO 2768 (General Tolerances for Linear and Angular Dimensions)
    • Machinery Directive 2006/42/EC
    • REACH and RoHS regulatory compliance for manufacturing safety

    Typical usage ratio

    • Used at 90–100% in structural elements; blend ratios adjusted if anti-static or color masterbatches are incorporated for optical detection lines.

    Downstream process integration

    • Directly processed in high-precision injection molding; integrates into assembly lines with automated screw fixing or snap-fit joints; may include inline laser or inkjet part marking.

    Final product types

    • Bearing cages
    • Machine guard covers
    • End-of-arm tooling
    • Precision guide bushings

    5. Water Treatment Systems—Valve and Pump Components

    Manufacturers of water and wastewater treatment systems leverage this PA12 compound in the construction of valve housings, pump impellers, and structural girders exposed to pressurized, chemically aggressive, or temperature-variable fluids. Materials engineers depend on the solution’s hydrolytic stability and low water absorption, which prevents swelling and dimensional drift during system lifetime. The inclusion of glass fiber enables long field service intervals and reduces maintenance costs versus alternatives.

    Industry compliance standards

    • WRAS (Water Regulations Advisory Scheme—UK)
    • KTW Guideline (German certification for plastics in contact with drinking water)
    • NSF/ANSI 61 (Drinking Water System Components—Health Effects)
    • ISO 21003 (Plastics piping systems for hot and cold water installations—Multilayer pipes)

    Typical usage ratio

    • Deployed at 100% for wetted parts such as valve bodies and impellers; may blend 80–90% for non-pressurized components where cost or impact modification is required.

    Downstream process integration

    • Material loaded into multi-cavity injection molds; post-process includes leak integrity testing, pressure cycling, and, for potable water products, cleaning and pre-certification batch sampling.

    Final product types

    • Pump rotor housings
    • Control valve actuators
    • Filter assembly mounts
    • Water meter shells

    6. Rail and Mass Transit Interior Fittings

    Specialty manufacturers in the railway and mass transit sector adopt this PA12 with glass fiber for seating fixtures, overhead handrail brackets, luggage racks, and modular wall panels. The enhanced impact strength and flame retardant properties directly address strict fire-safety and durability requirements, enabling extended service intervals and passenger safety. The compound’s resistance to graffiti cleaning chemicals and UV stability ensures components maintain their appearance and structural role over intensive public operation cycles.

    Industry compliance standards

    • EN 45545-2 (Fire Protection on Railway Vehicles—Requirements for Materials and Components)
    • NFPA 130 (Fire Protection for Fixed Guideway Transit and Passenger Rail Systems—US)
    • UNI CEI 11170 (Italian norm for fire behavior of railway vehicles)
    • REACH and RoHS for public installation safety

    Typical usage ratio

    • Applied at 100% for structural supports subject to direct passenger use; adjust by 10–20% for fiber blend or anti-graffiti coatings integration in visual elements.

    Downstream process integration

    • Feedstock enters large-format injection presses with fire-resistance certifiable formulations; subsequent plasma or UV-curable coating applied for advanced graffiti resistance.

    Final product types

    • Seat shell supports
    • Handrail brackets
    • Partition trims
    • Luggage bin underframes
    Free Quote

    Competitive CENTROPLAST CENTROMID 12 GF 30 Polyamide 12 30% glass fiber prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to admin@sinochem-nanjing.com.