Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing sales6@sinochem-nanjing.com
Follow us:

Lamprecide

    • Product Name Lamprecide
    • Alias Aminexilate
    • Einecs 253-384-9
    • Mininmum Order 1 g
    • Factory Site Tengfei Creation Center,55 Jiangjun Avenue, Jiangning District,Nanjing
    • Price Inquiry sales6@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    903957

    Product Name Lamprecide
    Active Ingredient 3-trifluoromethyl-4-nitrophenol (TFM)
    Formulation Liquid
    Application Aquatic pesticide
    Target Species Sea lamprey larvae
    Use Domain Freshwater streams and rivers
    Registration Status EPA registered
    Toxicity Selective to lampreys, lower toxicity to most other fish
    Appearance Amber to yellowish liquid
    Solubility Soluble in water
    Method Of Application Metered drip application
    Primary Use Region Great Lakes Basin
    Mode Of Action Disrupts cellular respiration
    Storage Conditions Store in a cool, dry, well-ventilated area
    Manufactured By U.S. Fish and Wildlife Service

    As an accredited Lamprecide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Lamprecide is packaged in a sturdy 500g white plastic container, featuring hazard symbols, precautionary statements, and a tightly-sealed red cap.
    Shipping Lamprecide must be shipped in secure, sealed containers that prevent leaks and contamination. The chemical should be clearly labeled, handled as hazardous material, and transported according to local and international regulations. Use secondary containment, temperature control if required, and ensure documentation accompanies the shipment for safety and compliance purposes.
    Storage Lamprecide should be stored in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and incompatible substances. Keep the container tightly closed when not in use and store it in a secure, clearly labeled area designated for hazardous chemicals. Ensure appropriate spill containment measures are in place, and access is restricted to trained personnel equipped with suitable protective equipment.
    Application of Lamprecide

    Applications of Lamprecide in Industrial Manufacturing

    As a specialized manufacturer supplying Lamprecide to industrial clients worldwide, we support downstream sectors with high-purity Lamprecide designed for stringent application needs. Below, we outline defined market sectors leveraging Lamprecide, with detailed compliance, formula, process, and finished goods information specific to each scenario.

    1. Agricultural Vector Control Solutions

    Major agrochemical formulators incorporate Lamprecide as an active ingredient in precision vector control products targeting lamprey infestations in commercial freshwater fisheries and aquaculture. Companies calibrate Lamprecide’s addition to eradicate larval and adult populations without disrupting aquatic ecosystems, aligning with evolving residue and application regulations. These applications rely on controlled dosage within integrated pest management programs, addressing regional species conservation concerns and sustainable water management initiatives.

    Industry compliance standards

    • US EPA Office of Pesticide Programs: Section 3 Registration and Section 24(c) Special Local Needs approvals for aquatic use
    • EU Regulation (EC) No 1107/2009 concerning the placing of plant protection products on the market
    • FAO/WHO International Code of Conduct on Pesticide Management
    • OECD Test Guidelines for Ecotoxicology and Environmental Fate

    Typical usage ratio

    • Application rates of 0.02 to 0.1 ppm active ingredient in treated waterways, calculated based on water flow volume, target biomass, and risk assessment findings

    Downstream process integration

    • Incorporation during batch formulation of liquid concentrate or wettable powder products, followed by blending with biodegradable surfactants and water conditioners, before packaging for field use or professional aquatic application services

    Final product types

    • Concentrated aquatic pesticides for direct application
    • Controlled-release vector control blocks
    • Professional-use fisheries management kits
    • Formulated bulk products for government or regulated entity supply

    2. Water Flow Remediation in Hydropower Reservoirs

    Hydropower facility operators and environmental remediation contractors utilize Lamprecide within programs targeting invasive lamprey management in dam reservoirs and river systems. This approach supports the restoration of native fish species populations and mitigates operational challenges posed by lamprey species on intake and screening infrastructure. Dosing protocols depend on flow dynamics, biomass monitoring, and require precise metering equipment during remediation projects.

    Industry compliance standards

    • Clean Water Act National Pollutant Discharge Elimination System (NPDES) permitting
    • EU Water Framework Directive 2000/60/EC for environmental quality control
    • US Fish and Wildlife Service Best Practice Guidelines: Selective Lamprey Control
    • ISO 14001 Environmental Management Systems for operational controls

    Typical usage ratio

    • Continuous metered dosing at 0.025–0.08 ppm, adjusted to real-time sensor data from intake monitoring and validated by environmental effect studies for site-specific limits

    Downstream process integration

    • Injection through automated chemical feed systems at reservoir inlets or fish passage points, coordinated with facility SCADA (Supervisory Control and Data Acquisition) for controlled release and feedback

    Final product types

    • Contract-bottled chemical treatment solutions for hydropower maintenance
    • Pre-mixed aquatic invasive remediation fluids
    • Site-specific lamprey mitigation treatment kits
    • Utility-grade application cartridges

    3. Fish Hatchery Protection Programs

    Certified fish hatcheries and aquaculture operations integrate Lamprecide in biosecurity protocols to protect stock from lamprey predation during rearing and transfer. Operators deploy this raw material in closed-loop recirculating aquaculture systems (RAS) and broodstock tanks, managing exposure times and post-treatment residue clearance with veterinary oversight. The precise Lamprecide load correlates with water volume, species sensitivity, and regulatory withdrawal periods to confirm non-detectable residues in harvested fish.

    Industry compliance standards

    • US FDA Compliance Policy Guides Sec. 615.115 & 615.125: Residues of Veterinary Drugs in Edible Aquatic Animals
    • Aquatic Animal Health Code (OIE)
    • Canadian Food Inspection Agency (CFIA) Aquaculture Drug Use Permits
    • Good Aquaculture Practice (GAP) certifications

    Typical usage ratio

    • Exposure concentrations typically 0.015–0.05 ppm; treatment intervals determined by larval lamprey monitoring, with subsequent system water changes for residue management

    Downstream process integration

    • Dosing via in-tank recirculation dosing pumps, monitored and sampled for residue analysis, followed by full or partial water replacement and filtration before end-of-cycle harvest

    Final product types

    • Hatchery-use biocidal treatment solutions
    • Pre-measured dosing packs for tank applications
    • Veterinary-supervised biosecurity kits for aquatic farms
    • Regulatory-compliant residue-free fish stocks

    4. Governmental and Conservation Agency Programs

    Government bodies and conservation agencies select Lamprecide for strategic deployment against invasive lamprey populations in protected watercourses, safeguarding endangered native taxa while aligning with biodiversity action plans. Projects require certified batches, managed traceability, and full environmental monitoring records. Authorities regulate the timing and documentation for Lamprecide use to minimize impact on non-target species under official restoration mandates.

    Industry compliance standards

    • National Invasive Species Act (NISA) implementation guidelines
    • Convention on Biological Diversity (CBD) invasive species protocols
    • Federal and regional environmental impact assessment (EIA) requirements
    • ISO 19011 Environmental Auditing for program traceability and reporting

    Typical usage ratio

    • Program-specified concentrations often 0.01–0.07 ppm, with formal impact and monitoring plans dictating repeated applications based on field survey results and protected species mapping

    Downstream process integration

    • On-site blending and dilution with sterile carrier liquids, accompanied by mobile dosing units during field campaigns, with batch sampling and chain-of-custody procedures enforced throughout deployment

    Final product types

    • Civil agency-registered aquatic bio-control products
    • Mobile dosing concentrates for protected waterways
    • Environmental restoration supply kits
    • Tracked application cycle reports for compliance audits

    5. Research and Analytical Reference Standards

    Research institutes and analytical laboratories require Lamprecide as certified reference material for environmental fate studies, toxicology screening, and development of new detection methodologies. In this sector, purity levels, batch homogeneity, and full analytical traceability matter for the integrity of reproducible scientific work. The substance supports protocol validation, matrix calibration, and regulatory method development in both environmental and biological sample analysis.

    Industry compliance standards

    • ISO 17034:2016 requirements for production of reference materials
    • OECD Good Laboratory Practice (GLP) principles
    • EPA Standard Methods for the Examination of Water and Wastewater
    • UN Globally Harmonized System (GHS) for classification and labeling during shipping and handling

    Typical usage ratio

    • Concentration and dosing defined by validation protocol; typical laboratory matrix spiking at 10–500 ng/mL for environmental monitoring, and 0.1–2 ppm for detection limit calibration depending on instrument sensitivity and target analyte range

    Downstream process integration

    • Dilution to analytical standards, use in spiking experiments for liquid chromatography, mass spectrometry, and field validation sampling; supporting laboratory workflows from reference standard preparation to matrix-specific calibration run setup

    Final product types

    • Chemical reference standards for residue analysis
    • Certified primary and secondary standard solutions
    • Spiking materials for inter-laboratory proficiency studies
    • Analytical control samples for regulatory submission
    Free Quote

    Competitive Lamprecide prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618018036652 or mail to sales6@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618018036652

    Email: sales6@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!