Wusu, Tacheng Prefecture, Xinjiang, China sales7@sinochem-nanjing.com
Follow us:

Corchorusoside E

    • Product Name Corchorusoside E
    • Alias Chikusetsusaponin IV
    • Einecs 120143-00-6
    • Mininmum Order 1 g
    • Factory Site Wusu, Tacheng Prefecture, Xinjiang, China
    • Price Inquiry sales7@sinochem-nanjing.com
    • Manufacturer Sinochem Nanjing Corporation
    • CONTACT NOW
    VTB
    Specifications

    HS Code

    920164

    Product Name Corchorusoside E
    Cas Number 93696-79-6
    Molecular Formula C29H44O12
    Molecular Weight 584.65 g/mol
    Synonyms Corchoroside E
    Appearance White to off-white powder
    Solubility Soluble in DMSO, methanol
    Purity ≥98% (HPLC)
    Storage Temperature -20°C
    Source Natural product, isolated from Corchorus olitorius
    Chemical Class Cardiac glycoside
    Iupac Name (3β,5β,8R,10β,13R,14β,17R)-2-[(6-deoxy-3-O-methyl-α-L-mannopyranosyl)oxy]-14-hydroxy-10-(hydroxymethyl)-13-methyl-17-[(2-O-acetyl-6-deoxy-3-O-methyl-α-L-mannopyranosyloxy)methyl]gona-1,3,5(10)-trien-12-one

    As an accredited Corchorusoside E factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Corchorusoside E is supplied in a 10 mg amber glass vial, sealed with a screw cap, labeled with product details and safety information.
    Shipping Corchorusoside E is securely packaged in airtight, chemical-resistant containers to ensure stability and prevent contamination during transit. The shipment complies with all relevant safety regulations, including labeling and documentation. Temperature-controlled shipping is provided as required, with tracking information supplied to ensure timely and safe delivery to the destination.
    Storage Corchorusoside E should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry place, ideally at 2–8°C (refrigerated). Avoid exposure to air and extreme temperatures. Proper storage conditions help maintain the stability and integrity of Corchorusoside E, ensuring its chemical efficacy and safety during handling and experimental use.
    Application of Corchorusoside E

    Applications of Corchorusoside E in Industrial Manufacturing

    Our direct manufacturing and quality control allow Corchorusoside E to serve several regulated and high-value segments. Below are verified industrial application scenarios including compliance, usage, integration, and finished-goods output, designed for advanced producers seeking reliable raw material sourcing.

    1. Pharmaceutical Cardiac Glycoside Formulations

    Cardiac drug manufacturers utilize Corchorusoside E as a core ingredient in the formulation of cardiac glycoside pharmaceuticals, particularly in regions where plant-derived actives are still preferred for specific applications. This compound enters directly into compounding and tableting processes after rigorous quality screening. Producers carry out quantitative HPLC verification due to its narrow therapeutic margin, and batch documentation is required for audit-traceability. Integration focuses on minimizing thermal degradation and solvent residue during downstream mixing and drying. Final output goes to prescription medications under hospital and clinic supply chains, with further stability and impurity profile testing mandated at the release stage.

    Industry compliance standards

    • ICH Q7 GMP for Active Pharmaceutical Ingredients
    • European Pharmacopoeia (Ph. Eur.) monographs for cardiac glycosides
    • FDA CFR Title 21, Part 211 (US drug GMP)
    • Chinese Pharmacopoeia specifications for botanically derived actives

    Typical usage ratio

    • 0.002%–0.01% in finished formulation, recalculated per batch according to validated pharmacokinetic parameters

    Downstream process integration

    • Weighing and dissolution during blended granulation
    • Added post-filtration in solution formulations
    • Pre-tableting quality verification using reference standards
    • Integration as a final step before enteric or film coating in tablets

    Final product types

    • Prescription heart failure tablets
    • Cardiac glycoside liquid preparations for hospital use
    • Specialty cardiac medicines for clinical trials and research supply

    2. Botanical Extract Standardization for Nutraceuticals

    Functional food and nutraceutical manufacturers use Corchorusoside E as a reference marker compound for the standardization of jute leaf and other herbal extracts. Supplement producers rely on batch consistency and authenticity checks, frequently requiring analytical reference standards sourced from manufacturers. The material enters the downstream workflow during blending and extraction validation and influences commercial batch release only after spectral and chromatographic confirmation. Quality systems mandate careful handling to avoid cross-contamination with non-standardized extracts, and finished goods must verify marker content within label claims before packaging and distribution.

    Industry compliance standards

    • ISO 22000 (Food Safety Management)
    • US FDA 21 CFR 111 (Dietary Supplement GMP)
    • EFSA (European Food Safety Authority) labeling guidelines
    • USP <561> Botanical Identification requirements

    Typical usage ratio

    • Reference standard: 0.001%–0.005% by weight in QC runs
    • Standardized extract: 0.02%–0.08% in finished powder or capsule

    Downstream process integration

    • Mixed into sample matrix for LC/MS identifier checks
    • Added to extraction lots as a spike for calibration curves
    • Used to set batch release criteria in QC laboratory workflow
    • Specification check before encapsulation and bottling lines

    Final product types

    • Standardized leaf and herbal capsules
    • Nutraceutical teas with botanical marker declaration
    • Jute-based dietary supplement blends

    3. Active Ingredient in Veterinary Formulations

    Veterinary pharmaceutical firms incorporate Corchorusoside E in livestock and companion animal drugs, principally for myocardial support indications. The compound is subject to veterinary pharmacopoeia standards during supply chain intake and requires validated analytical methods due to possible species-specific sensitivity. It enters pre-mixing or micro-encapsulation stages, with strict cross-contamination monitoring, especially in multi-use facilities. Producers target uniform dispersion during feed or bolus manufacture. Finished drugs require additional confirmatory tests for residual solvent and stability before market launch or supply to large-scale animal husbandry operations.

    Industry compliance standards

    • VICH GL9 (Good Manufacturing Practice for Active Pharmaceutical Ingredients in veterinary use)
    • European Directorate for the Quality of Medicines & Healthcare (EDQM) vet pharmacopeia
    • US FDA Guidance for Industry #61: Veterinary Pharmaceutical Ingredients
    • Chinese Veterinary Drug Quality Standards

    Typical usage ratio

    • 0.001%–0.005% for bolus or powder formulations, adjusted based on animal species and regulatory constraints

    Downstream process integration

    • Measured and mixed prior to granulation in premix batches
    • Encapsulation via low-heat technology to maintain compound stability
    • QC sampling after primary blending for dose uniformity testing
    • In-process verification before packaging into veterinary dosage forms

    Final product types

    • Veterinary boluses for ruminants
    • Powdered feed additives
    • Oral paste for equine cardiac management

    4. Research Chemical Supply for Analytical Laboratories

    Specialized research institutions and analytical laboratories demand high-purity Corchorusoside E as a reference compound for bioanalytical and phytochemical method development. We deliver material with certificate of analysis regarding purity, residual solvent, and structural identity verification. Analysts apply the material in trace-level LC/MS/MS or HPLC runs to set calibration curves for plant and drug content studies. Small-scale batch supply is critical as even minute impurities impact identification accuracy. Handling often occurs in ISO 17025 accredited environments with chain-of-custody procedures and batch traceability for research records.

    Industry compliance standards

    • ISO/IEC 17025 (Testing and Calibration Laboratories)
    • USP Reference Standard program requirements
    • GLP (Good Laboratory Practice) as per OECD
    • FDA Guidance for Bioanalytical Method Validation

    Typical usage ratio

    • Analytical standard: less than 0.001%, typically milligram quantities per sequence run; exact loading customized per method sensitivity

    Downstream process integration

    • Direct dissolution in sample preparation phase
    • Spiking into blank matrices for calibration curve and method validation
    • Added to control samples for system suitability testing
    • Used as check standard in long-sequence stability studies

    Final product types

    • Calibrant vials and laboratory reference kits
    • Published analytical standards for plant drug quantification
    • Bioanalytical controls for assay validation
    Free Quote

    Competitive Corchorusoside E prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@sinochem-nanjing.com

    Get Free Quote of Sinochem Nanjing Corporation

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance